Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 23

Owner's Manual: BayTech M Series DAC, pages 21 to 30

Pages 21 to 30 of 229

The original document is the PDF (499 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the BayTech M3 DAC

Page 21

M SERIES DAC CABLING ____________________________________________________________________________

If you are interfacing a DCE device such as a modem to the V71 DB-25 port, you must use a straight cable as shown in Appendix D. If you are interfacing a DTE device such as a terminal to the V71 DB-25 port, you must use a crossed or null modem cable as shown in Appendix D. V71 RJ-45 CABLING FOR EIA-232 The V71 provides EIA-232 line interface on the EIA-232 RJ-45 modular port. Most serial computers, modems, and printers do not have RJ-45 modular connectors. Adapters are required to convert from DB-25 or DE-9 connectors to modular connectors. BayTech has a complete line of RJ-45 adapters and cables that make your installation quick and trouble free. There are drawings, in Appendix D, of an RJ45 receptacle and plug where pin number assignments are given. The V71 EIA-232 modular port uses the following signals: EIA-232 RJ-45 PIN/SIGNAL DEFINITION Direction Description

P i n

EIA-232 Signal

1

DTR

Output

2

GND

----

3

RTS

Output

4 5

TX RX

Output Input

6

N/A

----

Not Used

7

GND

----

Signal Ground

8

CTS

Input

Handshake characters

Handshake Out, enable/disable the receiving of characters Signal Ground +12V when powered is applied, not used as a handshake line Transmit Data (data out) Receive Data (data in)

In, enable/disable the transmission of

COMPUTER INTERFACE, MODEM INTERFACE An adapter is required to connect an IBM PC to the V71 serial port. The 9FRJ45PC1 and 25FRJ45PC-1 adapters are used for this connection. The 25MRJ45MD-1 adapter is used to connect to an external modem. The pinout for these adapters is displayed in Appendix D. IMPORTANT: When modular connectors are used, crossed RJ-45 cables are required.

9

Page 22

M SERIES DAC CABLING ____________________________________________________________________________

V71 EIA-422 LINE INTERFACE NOTE: When using EIA-422 line interface, you must access configuration mode and reconfigure the line interface to EIA-422. V71 RJ-45 CABLING FOR EIA-422 The V71 RJ-45 port uses the following signals for EIA-422 communication:

Pin

RJ-45 PIN/SIGNAL DEFINITION FOR EIA-422 LINE INTERFACE EIA-422 Direction Description Signal

1

HSO

Output

2

GND

----

Handshake Out, enable/disable the receiving of characters Signal Ground

3 4

TX+ TX-

Output Output

Transmit Data (+) Transmit Data (-)

5 6

RXRX+

Input Input

Receive Data (-) Receive Data (+)

7 8

GND HSI

---Input

Signal Ground Handshake In, enable/disable the transmission of characters

You can use either RJ-45 (8-wire) or RJ-11 (4-wire) cabling when connecting the host computer or terminal to the V71 using EIA-422 line interface. The required cable should have TX+ connected to RX+ (and vice versa), TX- connected to RX- (and vice versa), HSO connected to HSI (and vice versa), and have the signal grounds connected. V71 (EIA-422, 8-wire) RJ-45 1 HSO 2 GND 3 TX+ 4 TX5 RX6 RX+ 7 GND 8 HIS

Equipment Connections HSI GND RX+ RXTXTX+ GND HSO

V71 RJ-45 (8-wire) Connection for EIA-422 Line Interface

10

Page 23

M SERIES DAC CABLING ____________________________________________________________________________

NOTE: If you wish to use RJ-11 (4-wire) cabling, connect pins 3 through 6 on the RJ-45 connector as shown above. In addition, you should enable XON/XOFF handshaking as described on page 49.

V71 DB-25 CABLING FOR EIA-422 IMPORTANT: If you intend to use EIA-422 line interface utilizing the DB-25 connector on the V71, you must change the jumper setting on the V71 board as described below. The V71 supports EIA-232, EIA-422, and current loop line interface. Line interface is programmed by accessing the configuration mode. From the factory, the DB-25 port and the EIA-232 RJ-45 port are the communication ports when EIA-232 line interface is selected. The DB-25 port is the communication port if current loop line interface is selected. The EIA-422/485 RJ-45 port is the communication port when EIA-422 line interface is selected. You can change the DB-25 port to support EIA422 line interface by changing a jumper setting on the V71 board. If you wish to change the jumper setting to allow the DB-25 port to support EIA-422 line interface, use the following procedure: If the V71 is installed in the M Series chassis, remove power from the unit by positioning the on/off switch to the off position and removing the power cord from the AC outlet. Unscrew the two straight slot screws securing the V71 to the back panel and pull the module out. Refer to the drawing below to locate jumper JP4. The board is marked 232 for EIA-232 line interface and 422 for EIA-422 line interface. JP4 has six pins and a dual shunt jumper. The center two pins are common pins. To change the existing jumper setting to support the desired line interface, position the dual shunt jumper so that it connects the two common pins and the two 232 pins or the two 422 pins. The V71 DB-25 port uses the following signals when configured for EIA-422 communication: Pin # 1 2 3 5

DB-25 PIN/SIGNAL DEFINITION FOR EIA-422 LINE INTERFACE EIA-422 Direction Description Signal PGND ---Protective Ground TXOutput Transmit Data (-) RXInput Receive Data (-) HSI

Input

Handshake In, enable/disable the transmission of characters

11

Page 24

M SERIES DAC CABLING ____________________________________________________________________________ 7

SGND

----

Signal Ground

14

TX+

Output

Transmit Data (+)

16

RX+

Input

Receive Data (+)

20

HSO

Output

Handshake Out, enable/disable the receiving of characters

The required cable should have TX+ connected to RX+ (and vice versa), TXconnected to RX- (and vice versa), HSO connected to HSI (and vice versa), and have the signal grounds connected as shown below. V71 (EIA-422) DB-25

Equipment Connections

1 GND 2 TX3 RX5 HSI 7 GND 14 TX+ 16 RX+ 20 HSO

GND RXTXHSO GND RX+ TX+ HSI

NOTE: If you wish to use RJ-11 (4-wire) cabling, connect pins 3 through 6 on the RJ-45 connector as shown above. In addition, you should enable XON/XOFF handshaking as described on page 49. V71 CURRENT LOOP LINE INTERFACE IMPORTANT: If you intend to use current loop line interface, you must use the DB-25 connector on the V71 and reconfigure the line interface to current loop as described on page 49 Current loop line interface provides active transmit and active or passive receive signals. The V71 RJ-45 port uses the following signals for current loop line interface with active transmit and passive receive: DB-25 PIN/SIGNAL DEFINITION FOR CURRENT LOOP (ACTIVE TX PASSIVE RX) Pin#

Current Loop Signal

Direction

Description

9

TX+

Output

Transmit Data (+)

12

Page 25

M SERIES DAC CABLING ____________________________________________________________________________ 11

TX-

Output

Transmit Data (-)

18

RX+

Input

Receive Data (+)

25

RX-

Input

Receive Data (-)

The V71 RJ-45 port uses the following signals for current loop line interface with active transmit and active receive: DB-25 PIN/SIGNAL DEFINITION FOR CURRENT LOOP (ACTIVE TX ACTIVE RX) Pin#

Current Loop Signal

Direction

Description

7

GND

----

Ground

9

TX+

Output

Transmit Data (+)

11

TX-

Output

Transmit Data (-)

18

RX-

Input

Receive Data (-)

19

RX+

Input

Receive Data (+)

25

GND

----

Ground

The figures below show the basic active transmit circuit, the basic passive receive circuit, and the basic active receive circuit.

Basic Active Transmit Circuit

13

Page 26

M SERIES DAC CABLING ____________________________________________________________________________

Passive Receive Circuit

Active Receive Circuit The figure below shows the recommended cable to connect the host computer to the V71 with active transmit and passive receive. V71 (Current Loop) DB-25

Equipment Connections

9 TX+ 11 TX18 RX+ 25 RX-

RX+ RXTX+ TX-

Recommended Cabling Using Current Loop Line Interface (Active Transmit Passive Receive) The next figure shows the recommended cable to connect the host computer to the V71 with active transmit and active receive. V71 (Current Loop) DB-25

14

Equipment Connections

Page 27

M SERIES DAC CABLING ____________________________________________________________________________

9 TX+ 11 TX18 RX19 RX+ 7 25

RX+ RXTXTX+ GND GND

Recommended Cabling Using Current Loop Line Interface (Active Transmit Active Receive) NOTE: The preceding figures show the transmit and receive connections in pairs. Each pair should be connected with twistedpair cabling. V72TP 10BASE-T (MODULAR) CONNECTION If your network uses 10BASE-T RJ-45 connectors, connect an RJ-45 cable between the RJ-45 port and the network hub. The modular port is defined as DTE (i.e., Pin 1 is TD+, Pin 2 is TD-, Pin 3 is RD+, and Pin 6 is RD-). Most RJ-45 network hubs will require a straight cable type. The LINK (link integrity) LED on the back panel and at the connected port on the hub will illuminate if there is a good connection between the V72/V72TP and the hub. V74/V75/V87 CABLING Ports on the V74 & V75 modules use the following pins and signals for communication: V74 & V75 PINOUT INFORMATION PIN

1

SERIAL INTERFACE RS-232 V74/75

RS-422 V75

DTR

HSO or +12V

DIRECTION

Output

DESCRIPTION

232 - Data Terminal Ready 422 - Handshake Out or +12V

Used to enable or disable the receiving of characters

15

Page 28

M SERIES DAC CABLING ____________________________________________________________________________ 2

GND/ DCD OUT

GND

--- / Output

Signal Ground(Default) or User selectable DCD "OUT"

3

RTS

TX+

Output

232 - +12V Out 422 - Transmit Data (+)

4

TX

TX-

Output

232 - Transmit Data 422 - Transmit Data (-)

5

RX

RX-

Input

232 - Receive Data 422 - Receive Data (-)

6

DSR

RX+

--- / Input

232 - Handshake In 422 - Receive Data (+)

7

GND/ DCD IN

GND

--- / Input

Signal Ground(Default) or User selectable DCD "IN"

8

CTS

HSI

Input

232 - Clear To Send 422 - Handshake In

Used to enable or disable the transmitting of characters

IMPORTANT: Before you proceed with cabling your equipment to this module, you should verify the connector type and the pin/signal definitions for your equipment. Ports on the V74, V75, and V87 modules have 8-pin modular connectors. Most serial computers, modems, and printers do not have modular connectors. Therefore, adapters are required to convert from either DB-25 or DE-9 connectors to modular connectors. BayTech has a complete line of modular adapters and cables that makes your installation quick and trouble free. CAUTION: Do not use 4-wire modular cabling with the V74 & V 75 modules. V74 & V75 DCD STATUS SELECTION Each EIA-232 port can be configured so DCD can be an input or output signal by positioning jumpers on the main board of the module for each individual port. See V74 & V75 Jumper selection layout(Figures 29 & 30 or V75 Mechanical Layout Section D.2). A. GROUND---Pins 2 & 7 of each port are signal ground in the default setting. This default setting is used in most data acquisition and control applications. Locate the

16

Page 29

M SERIES DAC CABLING ____________________________________________________________________________ eight jumper locations for DCD status selection. Jumpers (JP5,JP7,JP9, & JP11) are used to configure DCD as an output for pin 2 for each port of the module. Jumpers (JP6,JP8,JP10, & JP12) are used to configure DCD as an input for pin 7 for each port of the module. Each port is configured from the factory with pins 2 and 7 as ground. 1. V75 (See Figure 29)--- Each port's jumper position for "ground" connects the center pin and the pin located closest to the RJ-45 connector. 2. V74 (See Figure 30)--- Each port's jumper position for"ground" connects the center pin and the pin located on the right with the RJ-45 connectors facing you. In both V74 and V75 applications use BayTech adapter, part number 25FRJ45PC-1 or 9FRJ45PC-1. B. DCD "IN"---The DCD "IN" jumper selection is selected in applications where the individual port of the V74 or V75 will be communicating with a modem. To change the EIA-232 pin/signal definition for a V74 or V75 port to have pin 7 configured for DCD "IN" you must change the location JP6 for port 4, JP8 for port 3, JP10 for port 2, or JP12 for port 1. 1. V75 (See Figure 29)---Install the two position jumper so that it connects the center pin and the pin farthest away from the RJ-45 port. Do not move the other jumpers. 2. V74 (See Figure 30)---Install the two position jumper so that it connects the center pin and the pin located on the left of the common pin with the RJ-45 port facing you. Do not move the other jumpers. In these two applications use BayTech adapter, part number 25FRJ45MD-4. C. DCD "OUT"---The DCD "OUT" jumper selection is used in applications where an individual port of the V75 will look like a modem connection if a computer or terminal is connected to the port. Some terminals and popular communications software packages require that DCD is "high" for a connection to be completed. To change the EIA-232 pin/signal definition for a V74 or V75 port to have pin 2 configured for DCD "OUT" you must change the location of JP5 for port 4, JP7 for port 3, JP9 for port 2, or JP11 for port 1. 1. V75 (See Figure 29)---Install the two position jumper so that it connects the center pin and the pin farthest away from the RJ-45 port. Do not move the other jumpers. 2. V74 (See Figure 30)---Install the two position jumper so that it connects the center pin and the center pin and the pin located on the left of the common pin with the RJ-45 connectors facing you. Do not move the other jumpers. In this application use BayTech adapter, part number 25FRJ45PC-3 or 9FRJ45PC-3. IMPORTANT: If the module is installed in the base unit chassis, remove power from the unit by positioning the On/Off switch to "0" (off) and unplugging the power cord from the AC outlet. Remove the module by

17

Page 30

M SERIES DAC CABLING ____________________________________________________________________________ unscrewing the two screws securing it to the back panel and pulling the module out. 14.1.2 DCD STATUS SELECTION CHART--EIA-232 MODE ONLY (see the charts below for jumper settings) A. DCD "GROUND" is the default setting where DCD is not used by either end of the connection(modems are not used). See figures 29 & 30 for jumper locations.

PORT #

JP POSITIONS

PORT #1

11 GROUND 12 GROUND

PORT #2

9 GROUND 10 GROUND

PORT #3

7 GROUND 8 GROUND

PORT #4

5 GROUND 6 GROUND

USE ADAPTER: 25FRJ45PC-1 OR 9FRJ45PC-1 B. DCD "OUT" or high for computers or terminals connected to the V74 or V75 that will to be communicating with a modem. See figures 29 & 30 for jumper locations.

PORT #

JP POSITIONS

PORT #1

11 OUT 12 GROUND

PORT #2

9 OUT 10 GROUND

PORT #3

7 OUT 8 GROUND

PORT #4

5 OUT 6 GROUND

USE ADAPTER: 25FRJ45PC-3 OR 9FRJ45PC-3

18