Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 23

Owner's Manual: BayTech M Series DAC, pages 11 to 20

Pages 11 to 20 of 229

The original document is the PDF (499 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the BayTech M3 DAC

Page 11

M SERIES DAC TABLE OF CONTENTS ____________________________________________________________________________

ENERGIZE RELAY COMMAND.......................................................................155 DATA MESSAGE GENERATION AND RELAY CONTROL.........................155 DATA MESSAGE PRESENTATION .....................................................................156

V79 AND V80 OPERATION ............................................................. 157 GENERAL.....................................................................................................................157 USER-PROGRAMMABLE FEATURES................................................................158 SAMPLING SETUP................................................................................................158 REPORTING SETUP..............................................................................................158 REPORTING METHOD....................................................................................158 REPORT START TIME.....................................................................................158 REPORT INTERVAL.........................................................................................159 HOST ADDRESS................................................................................................159 TIME TAG............................................................................................................159 TERMINATING CHARACTER(S).................................................................159 DYNAMIC CONFIGURATION..........................................................................159 DATA COMMANDS..................................................................................................159 CLEAR EVENT BUFFER COMMAND............................................................160 CLEAR EVENT COUNTER COMMAND........................................................161 CLEAR EVENT LATCH DATA .........................................................................161 REPORT ALL BUFFERED EVENTS COMMAND........................................161 REPORT EVENT COUNTER COMMAND......................................................161 REPORT EVENT DURATION COMMAND...................................................162 REPORT EVENT LATCH DATA COMMAND..............................................162 REPORT EVENT COUNTER AND RESET COMMAND ............................162 REPORT EVENT LATCH DATA AND RESET COMMAND.....................162 REPORT A SINGLE BUFFERED EVENT COMMAND...............................163 EVENT SAMPLE REPORTING...............................................................................163 EVENT SAMPLE PRESENTATION ......................................................................164

V82 OPERATION ............................................................................. 166

TECHNICAL SUPPORT................................................................ 184 REPACKAGING, SHIPPING, AND RETURNING UNIT TO THE FACTORY........................................................................................ 188 FCC RADIO FREQUENCY INTERFACE STATEMENT......... 190 APPENDIX A -SPECIFICATIONS ............................................... 192 APPENDIX B -MODEM COMMAND SUMMARY.................... 203 APPENDIX C -MODULE COMMAND SUMMARY.................. 204 APPENDIX E.................................................................................... 213 xi

Page 12

M SERIES DAC TABLE OF CONTENTS ____________________________________________________________________________

INDEX ............................................................................................... 215 xii

Page 13

M SERIES DAC INTRODUCTION TO THE M SERIES DAC ____________________________________________________________________________

INTRODUCTION TO THE M SERIES DAC The BayTech M Series Data Acquisition and Control (DAC) models are versatile multifunction units used in data collection and process control. Typical applications include security alarm monitoring, HVAC systems, medical data systems control, manufacturing, and environmental data control. An M Series system consists of a base unit, host communication module(s), and various I/O modules. The base unit is comprised of 3, 4, 6, 9, or 16 card slots, activity LEDs, service port, time-of-day clock (optional), power supply, and an internal high speed data bus. The service port and optional service modem allow menu-driven configuration of the main unit and installed modules from a local or remote terminal. The host communication modules are the primary user interface to the M-Series DAC system. These modules allow the user to connect to the main unit or I/O modules and change configuration, send and receive data, and issue data commands. The host modules include:

(V71) Host Module (V72TP) Host Module (V93A) Host Module

Introduction

Configuration page 2 page 2 page 2 page 47 page 51 page 98

Operation page 107 page 109 page 177

IMPORTANT: The first module slot of any unit equipped with LCD and front panel controls must be occupied by a host module. The I/O modules are used to interface directly to various peripheral devices such as security/alarm systems, process control systems, medical data systems, and environmental control systems. The I/O module types include: Introduction (V74) (V75) (V87) (V77)

(V78)

1

A 4 EIA-232 serial I/O port module page 3 A 4 EIA-232/422 I/O port module page 3 A 4 EIA-485/422 I/O port module page 3 An 8 or 16 channel 12 bit A/D convertor page 3 An 8 channel control relay page 4

Configuration

Operation page 57 page 132 page 57 page 132 page 57 page 132 page 64 page 142 page 80 page 150

Page 14

M SERIES DAC INTRODUCTION TO THE M SERIES DAC ____________________________________________________________________________

(V79/V80)A 16 channel switch or optically isolated inputs (V82) A Programmable Control module (M03) A 16 MB memory module page 5 page 90 page 157 page 5

----- page 166 page 5

-----

-----

THE V71 Host Communication Module is a user interface to the BayTech M Series Data Acquisition and Control (DAC) units. This module allows a connected host terminal to issue specific configuration or data commands to the various I/O modules or the M Series unit main board. Multiple V71 modules can be installed in an M Series chassis allowing certain I/O module types to send data to specific V71 modules. The V71 module allows for multiple line interface types including EIA-232, EIA-422, and current loop and supports serial speeds up to 115.2K bps. Other programmable features in addition to the serial interface and baud rate include word size, stop bits, parity, XON/XOFF handshaking, and the port select code. In addition, the V71 module allows for RJ-45 or DB-25 cabling. THE V72TP host communications modules are a user interface for use with the BayTech M-Series Data Acquisition and Control (DAC) units. The V72TP allows network users, operating on a device using a TCP/IP stack with an Ethernet connection, to access various DAC peripheral modules. The V72TP host communications module has an Ethernet interface which provides access and control of M-Series DAC peripheral modules via TELNET session or through user software using a direct socket connection. The V72TP is capable of concurrently supporting one connection per installed port. For example, an M16 with a V72TP and fifteen V74 4-port serial I/O modules can be operated with a separate connection to each port for a total of 60 simultaneous sessions. The V72TP supports Ethernet II and Ethernet SNAP frame types automatically, eliminating concern about DLC compatibility. V93A The V93A Host Communication Modem Module is the remote user interface to the BayTech M Series DAC units. This module features a V.32bis/V.42bis internal modem and allows a remote host terminal to connect and issue specific configuration or data commands to the various I/O modules or the M Series DAC unit main board. Multiple V93A modules can be installed in a M Series chassis allowing I/O modules to send data to specific V93A modules. IMPORTANT: You should determine what types of peripheral modules you have installed in your M-Series DAC unit in addition to the host module. You should familiarize yourself with the various operation modes of the installed peripheral modules.

2

Page 15

M SERIES DAC INTRODUCTION TO THE M SERIES DAC ____________________________________________________________________________

THE V74, V75, and V87 I/O modules are installed in a BayTech M Series DAC and are used in conjunction with a host module. The V74 has four EIA-232 serial ports, the V75 has four selectable EIA-232/EIA-422 serial ports, and the V87 has four selectable EIA-422/EIA-485 serial ports. These modules allow a host computer system connected to the host module to individually select up to four peripheral devices (e.g., bar code readers, security systems, digital instruments, etc.) and send data to, or receive data from the selected device. The V74/V75/V87 modules will simultaneously multiplex incoming data from the peripheral devices to be transmitted to the host system. The method of data transmission from the peripheral devices to the host system is dependent upon the mode of operation. Each 4-port serial module features three user-selectable modes of operation. The three modes of operation are: Full Duplex Communication - Allows the host module to switch between four peripheral devices and provides bidirectional data transfer between the host module and the selected peripheral device. Data received from non-selected peripheral devices is stored in a buffer until the port is selected by the host system. Immediate Reporting Method - Provides automatic message multiplexing from all peripheral devices. Data is buffered until a terminating character is received or 256 characters are received. Messages are then sent to the host computer preceded by a port identification code. Command Reporting Method - Reports a single message, all messages, or all buffered data from specific peripheral devices upon request from the host computer. The V74/V75/V87 may be placed into "broadcast" mode where any data received by a host module will be sent out all four ports of the selected module(s) simultaneously. In addition to the modes of operation, you may select the serial port configuration and logical name for each port, the designated host module location, and the message terminate character. These parameters are programmed by entering configuration mode from the host module or service port. Changes are saved permanently in nonvolatile memory. THE V77 ADM-1 programmable analog-to-digital input board, is a plug-in module designed for use with the BayTech M Series DAC Data Acquisition Controllers. The primary feature of the ADM-1 is a 12 bit, successive approximation, analog-to-digital converter which provides conversion of data with high accuracy and resolution at moderate throughput rates. The ADM-1 can be operated as either eight differential or 16 single-ended inputs. Signal input connections to the ADM-1 are made through a standard DB-25 female connector. Data resolution is 12 bits using unipolar (0 to +X volts) operation or 11 bits plus sign in the bipolar (-X to +X volts) mode. A total of eight software selectable and one hardware (jumper) selectable, unipolar/bipolar input voltage ranges 3

Page 16

M SERIES DAC INTRODUCTION TO THE M SERIES DAC ____________________________________________________________________________ are available. Three point (25%, 50% 75%) self-calibration is provided in software to reduce or remove errors introduced by input offsets. Sample rates up to 4000 S/sec and data averaging from 1 to 4000 samples are selectable through configuration options. Data averaging can be expanded to include larger sample sets through the use of BayTech, or commercially available, application software. Time stamping or "Time Tagging" of data is available through the use of a "time-of-day" clock located in the base unit. A time tag includes month, day, year, hour, minute and second. Data samples are supplied to the host computer/controller from any of the following modes: 1. 2. 3.

Upon user request (COMMAND). At a specific date and/or time (SCHEDULE). Real time sampling (i.e., as samples are received or IMMEDIATE).

THE V78 CRM-1 eight channel, control relay module is a microprocessor controlled plug-in unit designed for use with the BayTech M16 Data Acquisition Controllers. The main feature of the CRM-1 is eight (8) fully programmable, electromechanical, form-C, single-pole-double-throw (SPDT) relays. Each relay has a set of normally open (NO) and a set of normally closed (NC) contacts. All relays on the V78 CRM-1 are programmable to change state by sending data commands or via time schedule by a host computer/controller. The status of a relay (energized or de-energized) may be requested by a host computer/controller. The relay status may consist of buffered data representing the history of changes in the state of a specific relay or the current state of a specific relay. The relay status may be provided with a "time stamp or "Time Tag" which is available through the use of a "time-of-day" clock located in the base unit. A time tag includes the month, day, year, hour, minute and second the relay status was taken. Relay status data is supplied to the host computer/controller in one of the following modes: 1) 2) 3)

Upon user request (COMMAND). At a specific date and time (SCHEDULE). Real time reporting of events (IMMEDIATE). NOTE: An event is the change-in-state of a relay (i.e., energized to deenergized or vice versa).

Signal input connections to the CRM-1 are made through a standard DB-25F (25 pin female) connector.

4

Page 17

M SERIES DAC INTRODUCTION TO THE M SERIES DAC ____________________________________________________________________________

THE V79/V80 PDI modules are designed for use with the M16 (DAC) Data Acquisition Controller. Both modules are used to detect events where an event is defined as a change-in-state of an input and return to the original state. The V79 PDI1 module is used for the detection of switch closure in applications requiring notification of device status such as burglar alarms, fire alarms, event counters and timers, process control, etc.. The V80 PDI-2 is used for the detection of optically isolated voltage inputs in applications requiring industrial control of motors, process monitoring, limit switch status, and the monitoring of relay status. All events detected by either module are recorded as an event sample and sent to a host computer/controller connected to a host module. The current status of input channels may be provided to the host computer/controller upon request. Event samples or input channel status may be provided with a "time stamp" or "Time Tag" which is available through the use of a "time-of-day" clock located in the base unit. A time tag includes the month, day, year, hour, minute and second the event occurred or the input channel status was taken. Event status is supplied to the host computer/controller in one of the following modes: 1) 2) 3)

Upon user request (COMMAND). At a specific date/time (SCHEDULE). Real time reporting of events (i.e., as events occur IMMEDIATE).

THE V82 Programmable Control Module (PCM-1) is used to monitor, control, and report information about devices connected to the M-Series peripheral modules. The M-Series peripheral modules are used to interface directly to various devices such as security/alarm systems, process control systems, medical data systems, and environmental control systems. Bay Tech provides C library functions specific to the various peripheral modules. These functions allow you to write C programs to perform data acquisition and control applications such as process control, remote control and monitoring and data gathering. Programming the V82 PCM-1 is accomplished by writing a C-based source program, compiling and linking this program for use on the 64180 microprocessor, and downloading the corresponding HEX file to the flash EPROM. The C library functions provided are specific for the 2500AD software, Inc. 64180 C compiler. THE M03 memory module can hold from 1MB to 16MB total buffer size. It is used to expand the memory capabilities of the various module buffers.

5

Page 18

M SERIES DAC QUICK START ____________________________________________________________________________

QUICK START

6

Page 19

M SERIES DAC CABLING ____________________________________________________________________________

CABLING BASE UNIT CABLING SERVICE PORT/SERVICE MODEM CABLING If you have a unit equipped with a service modem, the cable required to connect the telephone interface to the modem port is a standard 4-pin modular straight-through cable. CAUTION: Use caution when installing or modifying telephone lines. Never install telephone wiring during a lightning storm. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. The service port has an RJ-45 modular connector. Most serial computers and terminals do not have modular connectors. Therefore, adapters are required to convert from DB-25 or DE-9 connectors to modular connectors. The service port uses the following communication signals:

SERVICE PORT 8-PIN MODULAR EIA-232 PIN/SIGNAL DEFINITION PIN

SIGNAL

DIRECTION

DESCRIPTION

1

DTR

Output

Data Terminal Ready. Enable/disable receiving characters

2

GND

--------

Signal Ground

3

RTS

Output

Request To Send. +12 Volts when unit is powered on.

4

TX

Output

Transmit Data

5

RX

Input

Receive Data

6

DSR

Input

Data Set Ready. Not used as a handshake line.

7

DCD

Output

Data Carrier Detect. +12 Volts when unit is powered on.

8

CTS

Input

Clear To Send. Enable/disable transmitting characters

An adapter is required to connect an IBM PC to the service port. The 9FRJ45PC-3 and 25FRJ45PC-3 adapters are used for this connection. The pinout for these adapters is displayed in Appendix D.

7

Page 20

M SERIES DAC CABLING ____________________________________________________________________________

V71 CABLING The V71 has a DB-25 and two RJ-45 connectors for interface to the host terminal. The V71 supports three line interfaces: EIA-232, EIA-422, and current loop. The factory default setting provides EIA-232 line interface on the DB-25 port and the EIA-232 RJ-45 port. The line interface is programmed by entering the V71 configuration mode (see page 47). If you change the line interface to EIA-422 in configuration mode, the default hardware settings provide EIA-422 line interface on the EIA-422/485 RJ-45 port. You can change a hardware jumper setting on the module that provides EIA-422 line interface on the DB-25 port. This procedure is discussed on page ??? Current loop line interface is provided on the DB-25 port only. IMPORTANT: Before you proceed with cabling your equipment to the V71, you should determine the required line interface for your application and verify the connector type and pin/signal definitions for your equipment. V71 DB-25 CABLING FOR EIA-232 The DB-25 port on the V71 has a male DTE type connector and uses the following pins and signals for communication: DB-25 PIN/SIGNAL DEFINITION FOR EIA-232 LINE INFORMATION

8

Pin #

EIA232 Signal

Direction

Description

1

PGND

----

2

TX

Output

Transmit Data (data out)

3

RX

Input

Receive Data (data in)

4

RTS

Output

+ 12 volts when the M16/M8 DAC is powered up.

5

CTS

Input

Handshake In, enable/disable the transmission of characters

7

SGND

----

Signal Ground

20

DTR

Output

Protective Ground

Handshake Out, enable/disable the receiving of characters