Page 11
1.3
ES SERIES
BayTech's ES Series multiplexers are designed to interface directly with a host computer and provide automatic time-division multiplexing of data from multiple peripheral devices thereby reducing the software overhead of the host system. The 524ES(P) models have one host port and four peripheral ports. The 528ES(P) models have one host port and eight peripheral ports. The Model 5218ESP has one host port and seventeen peripheral ports. Figure 3 below shows a typical application using an ES Series multiport controller.
Figure 3: ES Series Application The serial port configuration (baud rate, word size, stop bits, and parity) is user-selectable for each individual port on all ES Series models. In addition, the data block length, the control character, and XON/XOFF handshaking are programmable on the 528ESP and 5218ESP models. These features are easily programmed via the menu-driven configuration mode or by DIP switch settings (see Section 6). NOTE: The control character, and XON/XOFF handshaking are options to order (Option 2 and Option 6 respectively) on the 524ES(P) and 528ES models if the factory default values are not acceptable. The factory default control character is ASCII Control-T and XON/XOFF handshaking is disabled from the factory. Please call BayTech for ordering information (see Section 8).
5
Page 12
1.4
F SERIES
The F Series multiports allow you to create a local "star" network capable of any-port-to-any-port communication. A full duplex communication link is established between any two connected EIA-232 ports. The 525FP and 528FP also feature a host port control feature that will allow the host device to make or break any connection between two devices. The 524F(P) and 525FP models have one host port and four peripheral ports. The Model 528FP has one host port and eight peripheral ports. The Model 5218FP has one host port and seventeen peripheral ports. Figure 4 shows a typical application using an F Series multiport controller.
Figure 4: F Series Application The serial port configuration (baud rate, word size, stop bits, and parity) is user-selectable for each individual port on all F Series models. In addition, XON/XOFF handshaking, the output message strings, and the sign-on/sign-off character are programmable on the 525FP and 528FP models. These features are easily programmed via the menu-driven configuration mode or by DIP switch settings (see Section 6). NOTE: The control character and XON/XOFF handshaking are options to order (Option 2 and Option 6 respectively) for the 524F(P) and 5218FP models if the factory default values are not acceptable. The factory default control character is ASCII Control-T and XON/XOFF handshaking is disabled from the factory. Please see Section 8 for ordering information. NOTE: For all models, there is a disconnect time guard option to order (Option 7). This option will prevent an erroneous disconnect in the case that the sign-off character followed by a carriage return is sent as data. The disconnect time guard option requires a two (2) second delay between the last transmitted character and the sign-off character. Please see Section 8 for ordering information.
6
Page 13
1.5
G SERIES
The G Series multiports allow a host computer device to simultaneously broadcast the same message out to multiple peripheral ports while receiving data from an individual selected peripheral port. The G Series multiports can also operate in a mode identical to the A Series (i.e., a port expansion mode where the host device can individually select a single peripheral at time to communicate with in full duplex). The 524G and 525GP models have one host port and four peripheral ports. The 528G and 529GP models have one host port and eight peripheral ports. The Model 5218GP has one host port and seventeen peripheral ports. Figure 5 below shows a typical application using a G Series multiport controller.
Figure 5: G Series Application The serial port configuration (baud rate, word size, stop bits, and parity) are userselectable for each individual port an all G Series models. In addition, XON/XOFF handshaking and the control character are programmable for the 525GP and 529GP models. These features are easily programmed via the menu-driven configuration mode or by DIP switch setting (see Section 6). NOTE: The control character and XON/XOFF handshaking are options to order (Options 2 and 6 respectively) on the 524G and 5218GP models if the factory default values are not acceptable. The factory default control character is ASCII Control-T (14 hex) and XON/XOFF handshaking is disabled from the factory. Please see Section 8 for ordering information.
7
Page 14
2
SPECIFICATIONS INTERFACE: EIA-232C (CCITT V.24), -12v mark, +12v space. Optional EIA-422A (Option 17) and Current Loop (Option 12). TRANSMISSION: Asynchronous. FACTORY-SET POWER-UP DEFAULT CONFIGURATION - ALL MODELS EXCEPT AS NOTED: Baud rate: 9600. Word size: 8 bits. Parity: None. Stop bits: 1. XON/XOFF: Disabled. Control character: ^T (14 Hex). Data block length (ES only): 32 characters. Terminating character (AC11 Series only): Carriage Return (0D Hex) . Sign-On/Sign-off character (F Series only): ^T (14 Hex). Output Messages (F Series only): On Line Message: ^M^JOn line^G^M^J; Off Line Message: ^M^JOff line^M^J; Busy Message: ^M^JBusy^M^J . NOTE: The ^ symbol represents a control character. USER-PROGRAMMABLE CONFIGURATION ALL MODELS EXCEPT AS NOTED: Reconfigurable in menu-driven mode through the host port: Port 5 of the 524 and 525 units, Port 9 of the 528 and 529 units, and Port 18 of the 5218 units. Saved in non-volatile memory to become the new power-up default configuration for all programmable units. NOTE: Baud rate, word size, parity, and stop bits for the host port of 524 and non-programmable 528 units are programmed via DIP-switch settings. Baud rate: 110, 135, 300, 600, 1200, 2400, 4800, 9600. 19,200 is available on 524 and 525 units only. Other rates optional. Word size: 5, 6, 7 or 8 bits (7 or 8 bits for 524 models). Parity: Even, odd or none. Stop bits: 1, 1 1/2 or 2 (1 or 2 for 524 models). XON/XOFF: Enabled or disabled (Option to order on 524 models).
8
Page 15
Contr ol character: Any code from 00 Hex to 7F Hex (option to order on 524 units). Terminate character (528AC11P and 5218AC11P models only): Any code from 00 Hex to 7F Hex. Data block length (528ESP and 5218ESP models only): 1 to 250 characters. AVAILABLE OPTIONS: Option 2: Custom Control Character - Control character required to select between ports. Available on all 524 models, all non-programmable 528 models, 5218FP, and 5218GP. Programmable feature on all other models. Option 2H: Request for Message Command: ^T followed by capital S releases a message from any one of the peripheral ports. Available on 524AC11P only. Option 2I: Same Control and Configuration Character - Single control character to switch between ports and to configure peripheral ports. Available on all 524 models except 524F(P). Standard feature on all other models. Option 3C: Custom Connectors - DTE, DB-25 male connectors available per port. Available on all models. Option 4: 230 VAC power - Power supply to use 230 VAC power. Available on all models. Option 6: XON/XOFF Flow Control - Enables XON/XOFF handshaking on all ports. Available on 524AP, 524AC11P, 524ESP, 524FP, 5218FP, and 5218GP. Option 7: Disconnect Time Guard - With this option, a 2-second delay is required before the disconnect sequence. Available on 524FP, 525FP, and 528FP. Option 12: Current Loop - EIA-232 Current Loop interface available per port. Please specify active or passive transmit and active or passive receive. Available on all models.
9
Page 16
Option 17: EIA-422 interface available per port. Available on all models. Option 20: 525 Buffer Expansion - Receive buffer expansion to 7.7K per port. Available on 525FP and 525GP only. BUFFER SIZE: 525/529 - 3.7K Rx/256 byte Tx per port standard; 525 units optionally available with 7.7K Rx/256 byte Tx per port (Option 20). 524/528/5218 - 256-byte Rx/256-byte Tx per port. POWER: 524\525 - 115 VAC, 50/60 Hz, maximum .2A.; optional 230 VAC, 50/60 Hz, maximum .1A; 528/529/5218 - 115 VAC, 50/60 Hz., maximum .3A.; optional 230 VAC, 50/60 Hz., maximum .2A. ENVIRONMENT: 0 degrees to 50 degrees C temperature; 5% to 95% humidity. DIMENSIONS: 524 and 525 - 8 x 7 1/2 x 2 1/4 inches; 528/529 - 10 1/8 x 8 x 3 inches; 5218 - 16 3/4 x 10 1/8 x 3 1/2 10 inches. WEIGHT: 524/525 - 3 lbs.; 528/529 - 5 lbs., 5218 - 9 1/2 lbs. INDICATORS: 1 green power LED; red port-activity LEDs. CONNECTORS: DB-25s with DCE (female) ports. HANDSHAKING: CTS/DTR; selectable XON/XOFF on some models (XON/XOFF optional on 524 units and certain 5218 units). MOUNTING: Desk-top standard; rack-mount accessories optional. WARRANTY: One full year.
10
Page 17
3
INSTALLATION
3.1
UNPACKING
After opening the box, check the packing list that comes with your multiport to ensure that you have received all components and to determine the specific multiport model number you have purchased. At a minimum, you should have received the unit, this manual, and any applicable addendums. Also check the unit to make certain that it did not receive damage during shipping. If items are missing or damage did occur, please contact BayTech technical support at 1-800-523-2702.
3.2
POWER
All models come with standard 115VAC, 50/60 Hz. power and a three-prong power cord. Do not attempt to operate the unit with a two-prong socket or adapter. 230 VAC, 50/60 Hz. is optional. All models power-up when you depress the power switch on the back of the unit to "1". Power-on is indicated on the front panel by the illuminating of a green LED . CAUTION: Power should be turned off anytime cables are to be installed or removed. Make sure the power is turned off and the unit is unplugged before removing the cover and attempting to make any internal changes.
3.3
FACTORY DEFAULT CONFIGURATION
NOTE: Before you proceed with installation, make certain that the device connected to the host port is setup to have the same configuration as the multiport's host port. The host port and all other ports on all series of multiports are factory configured as follows except as noted: Serial ports power up from the factor y at: 9600 baud rate 8 word size 1 stop bit No parity XON/XOFF disabled (optional for 524 units and some 5218 units) Control character: ^T (14 Hex). Sign-On/Sign-off character (F Series only): ^T (14 Hex). Output Messages (F Series only): On Line Message: ^M^JOn line^G^M^J; Off Line Message: ^M^JOff line^M^J; Busy Message: ^M^JBusy, no port available^M^J. Data block length (ES Series units only): 32 characters. 11
Page 18
If the factory default configuration for all ports is not satisfactory for your application, you may then reconfigure the multiport by entering the configuration mode (see Section 6). The controlling or host device is connected via cable to the host port on all models. This is Port 5 of the 524 and 525 units, Port 9 of the 528 and 529 units, and Port 18 of the 5218 units. Peripheral devices are connected via cable to any of the remaining ports. They need not be installed in any specific order. Peripheral ports not used may be left empty.
12
Page 19
4
CABLING
IMPORTANT: Before you proceed with cabling, you must know whether the devices you are connecting to your multiport are DTE (Data Terminal Equipment) or DCE (Data Communication Equipment). The following devices are generally DTE: terminals, printers, and computers like the IBM PC. The following devices are DCE: modems and some computers. If your device transmits data on Pin 2 and receives data on Pin 3, it is DTE. If your device receives data on Pin 2 and transmits data on Pin 3, it is DCE. However, to verify the interface requirements for your device, please refer to the Owner's Manual for that device. BayTech's standard configuration of its multiports is all ports DCE with DB-25 female connectors. DCE ports use the following signals for communication: DCE PORT SIGNALS Pin
EIA-232 Signal
Direction
Description
1
PGND
----
Protective ground
2
TX
Input
Data in
3
RX
Output
Data out
4
RTS
Input
Internally enabled if no wire connected (normally not used).
5
CTS
Output
-12V when DCE device's buffer is full.
6
DSR
Output
+12V when DCE device powers-up.
7
SGND
----
Signal ground
20
DTR
Input
Transmit enabled when +12 V.
13
Page 20
If you are interfacing a DCE device to a DTE device, you must use a one-to-one straight cable as in Figure 6. If you are interfacing a DCE device to a DCE device, or a DTE device to a DTE device, you must use a crossed cable as in Figure 7. Input handshaking lines are enabled if nothing is connected, allowing the system to operate with only Tx, Rx and GND connected. 500 MODEL - DCE MALE DB-25
1
PGND
2
TXD
3
RXD
4
RTS
5
CTS
6
DSR
7
SGND
8
DCD
20
DTR
DTE DEVICE FEMALE DB-25
< >
1
TXD
2
RXD
3
RTS
4
>
CTS
5
>
DSR
6
SGND
7
DCD
8
DTR
20
<
> <
PGND
Figure 6 - 500 Series (DCE) to DTE Device 500 MODEL - DCE MALE DB-25
1
PGND
2
TXD
3
RXD
4
RTS
5
DCE DEVICE FEMALE DB-25
PGND < TXD RXD
3
<
< RTS
4
CTS
CTS
5
6
DSR
DSR
6
7
SGND
SGND
7
20
DTR
<
< DTR
Figure 7 - 500 Series (DCE) to DCE Device
14