The text of a manual · part 1 of 8
Owner's Manual: A Series, AC11 Series, ES Series, F Series, and G Series Multiport Controllers, pages 1 to 10
Pages 1 to 10 of 77
The original document is the PDF (195 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the BayTech 529 and BayTech 524
Page 1
OWNER'S MANUAL
A SERIES, AC11 SERIES, ES SERIES, F SERIES, AND G SERIES MULTIPORT CONTROLLERS 524A 524AP 528A 528AP 5218AP 524AC11 524AC11P 528 AC11 528 AC11P 5218AC11P 524ES 524ESP 528ES 528ESP 5218ESP 524F 524FP 525FP 528FP 5218FP 524G 525GP 528G 529GP 5218GP 524NB 524NBP 528NB 528NBP BayTech publication #U140E085-01
Page 2
Copyright 1993 - 1998 by Bay Technical Associates, Inc. IBM PC, IBM PC/AT, IBM PC/XT are products of International Business Machines Corporation. All products or company names are trademarks of their respective holders. Thank you for selecting a BayTech multiport controller. The data provided in this Owner's Manual explains the various ways you can operate your unit and configure it to your own computer system. We suggest that you read this manual carefully before attempting to install your multiport controller and that you place special emphasis on correct cabling and configuration. If you have any problems with your installation, please contact a BayTech applications engineer for assistance toll-free at 1-800-523-2702. BayTech also manufactures other data communications devices that provide port sharing and expansion, networking, port contention, buffered and non-buffered printer sharing, and multiplexing. If you would like information on any of these models, please contact BayTech Customer Service. The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Bay Technical Associates, Inc. In the interest of improving internal design, operational function, and/or reliability, Bay Technical Associates, Inc reserves the right to make changes to the products described in this document without notice. Bay Technical Associates, Inc does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein. We welcome any comments you may have about our multiports. And we hope that you will continue to look to BayTech for your data communications needs.
ii
Page 3
Table of Contents GENERAL INFORMATION
1
A SERIES
3
AC11 SERIES
4
ES SERIES
5
F SERIES
6
G SERIES
7
SPECIFICATIONS
8
INSTALLATION
11
UNPACKING
11
POWER
11
FACTORY DEFAULT CONFIGURATION
11
CABLING
13
OPERATION
15
OPERATING PROCEDURE
15
A SERIES PERIPHERAL PORT SELECTION BINARY MODE CASCADING - THE MODEL 5218C AC11 SERIES ES SERIES F SERIES G SERIES
15 15 16 17 17 18 19 20
USER-PROGRAMMABLE OPERATIONS
21
ALL 524 AND NON-PROGRAMMABLE 528 MODELS ALL 525, 528, 529, AND 5218 MODELS (EXCEPT 525FP AND 528FP) THE SERIAL PORT CONFIGURATION THE CONTROL CHARACTER 528AC11P AND 5218AC11P - THE MESSAGE TERMINATING CHARACTER 528ESP AND 5218ESP - SET DATA BLOCK LENGTH 525FP AND 528FP THE SERIAL PORT CONFIGURATION THE SIGN ON/SIGN OFF CHARACTER OUTPUT MESSAGE STRINGS
DATA FLOW CONTROL All 524, 528, 5218 MODELS
21 21 21 21 22 22 22 22 22 23
23 23 iii
Page 4
524NB(P) AND 528NB(P) NON-BUFFERED UNITS STANDARD 525/529 MODELS
CONFIGURATION ALL 524 MODELS - CONFIGURATION PROCEDURE HOST PORT CONFIGURATION ALL 524 MODELS EXCEPT 524F(P) - PERIPHERAL PORT CONFIGURATION STATUS SET SERIAL PORT CONFIGURATION 524F(P) PERIPHERAL PORT CONFIGURATION STATUS SET SERIAL PORT CONFIGURATION
24 25
27 27 27 29 29 29 31 31 32
ALL 528 NON-PROGRAMMABLE MODELS - CONFIGURATION PROCEDURE
34
HOST PORT CONFIGURATION PERIPHERAL PORT CONFIGURATION 528 PERIPHERAL PORT - STATUS 528 PERIPHERAL PORT - SET SERIAL PORT CONFIGURATION
34 36 37 38
ALL 525, 528(x)P, 529, AND 5218 MODELS (EXCEPT 525FP, 528FP, AND 5218FP) - CONFIGURATION PROCEDURE 40 528AP, 5218AP - MAIN CONFIGURATION MENU 528AC11P, 5218AC11P - MAIN CONFIGURATION MENU 528ESP, 5218ESP - MAIN CONFIGURATION MENU 525GP/529GP/5218GP - MAIN CONFIGURATION MENU STATUS SET SERIAL PORT CONFIGURATION SET CONTROL CHARACTER 528AC11P, 5218AC11P MODELS - SET MESSAGE TERMINATING CHARACTER 528ESP, 5218ESP MODELS - SET ALL 528/5218AP, AC11P, ESP MODELS XON/XOFF HANDSHAKING EXIT
525FP AND 528FP - CONFIGURATION PROCEDURE MAIN CONFIGURATION MENU STATUS PORT CONFIGURATION OUTPUT MESSAGE STRINGS SIGN ON/SIGN OFF CHARACTER EXIT
47 47 48 48
49 49 49 50 52 54 54
5218FP CONFIGURATION PROCEDURE
55
5218FP - STATUS 5218FP - SERIAL PORT CONFIGURATION
55 55
NON-VERBOSE MODE ALL 524 MODELS EXCEPT 524F(P) iv
40 40 41 42 42 44 46
57 58
Page 5
524F(P) - NON-VERBOSE MODE CONFIGURATION PROCEDURE ALL NON-PROGRAMMABLE 528 MODELS ALL 528 AP, AC11P, ESP, AND NBP MODELS 528AP, 528NBP, 5218AP - NON-VERBOSE MODE CONFIGURATION MENUS 528AC11P, 5218AC11P - NON-VERBOSE MODE CONFIGURATION MENUS 528ESP, 5218ESP - NON-VERBOSE MODE CONFIGURATION MENUS 5218FP - NON-VERBOSE CONFIGURATION PROCEDURE NON-VERBOSE MODE EXAMPLE
MAINTENANCE
59 59 60 60 62 63 64 65
67
RETURNS TO THE FACTORY
67
REPACKING FOR SHIPPING
67
TECHNICAL SUPPORT/ORDERING
68
FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFACE STATEMENT*
69
INDEX
70 v
Page 6
Page 7
1
GENERAL INFORMATION
IMPORTANT: Please verify which specific model multiport controller you have purchased (i.e., Type A, Type AC11, Type ES, etc.). Please see the packing list that came with your unit for the specific model type. There is a label on the rear panel indicating the series type. Also verify what hardware type you have purchased (i.e., 524, 525, 528, etc.). The hardware type is indicated on the front panel. Determine if you have purchased any options with your unit. NOTE: If your multiport controller has a "P" suffix at the end of the model type, this indicates the unit is equipped with non-volatile memory and will be referred as a programmable unit. If you change any factory default settings via the menu-driven configuration mode, the changes will be retained if power is lost. When a specific item in this manual applies to both programmable and non-programmable units, we will denote the model type with "(P)" (e.g., 524A(P), 528ES(P)). NOTE: If your multiport controller does not have a label on the back panel indicating the series type, you may assume you have purchased a 524NB(P) or 528NB(P). Please see the packing list to confirm. The following sections apply to all models: Section 2 (Specifications), Section 3 (Installation), Section 4 (Cabling), Section 7 (Maintenance), Section 8 (Technical Support/Ordering), and Section 9 (FCC Statement). You may skip subsections that do not pertain to the multiport you have purchased. Most subsections are titled with the specific model and/or hardware type. Please see TABLE A on the following page for a guide to which subsections apply to specific models.
1
Page 8
TABLE A - MODEL/SUBSECTION GUIDE Model
2
Applicable Subsections
524A(P)
1.1, 5.1.1, 5.2.1, 5.3.1, 6.1, 6.6
528A
1.1, 5.1.1, 5.1.1.1, 5.2.1, 5.3.1, 6.2
528AP
1.1, 5.1.1, 5.2.2, 5.3.1, 6.3, 6.6
5218AP
1.1, 5.1.1, 5.2.2, 5.3.1, 6.3, 6.6
524AC11(P)
1.2, 5.1.2, 5.2.1, 5.3.1, 6.1, 6.6
528AC11
1.2, 5.1.2, 5.2.1, 5.3.1, 6.2
528AC11P
1.2, 5.1.2, 5.2.2, 5.3.1, 6.3, 6.6
5218AC11P
1.2, 5.1.2, 5.2.2, 5.3.1, 6.3, 6.6
5218C
1.1, 5.1.1.3, 5.2.2, 5.3.1, 6.3, 6.6
524ES(P)
1.3, 5.1.3, 5.2.1, 5.3.1, 6.1, 6.6
528ES
1.3, 5.1.3, 5.2.1, 5.3.1, 6.2
528ESP
1.3, 5.1.3, 5.2.2, 5.3.1, 6.3, 6.6
5218ESP
1.3, 5.1.3, 5.2.2, 5.3.1, 6.3, 6.6
524F(P)
1.4, 5.1.4, 5.2.1, 5.3.1, 6.1.1, 6.1.3, 6.6
525FP
1.4, 5.1.4, 5.2.3, 5.3.3, 6.4
528FP
1.4, 5.1.4, 5.2.3, 5.3.1, 6.4
5218FP
1.4, 5.1.4, 5.2.2, 5.3.1, 6.5, 6.6
524G
1.5, 5.1.5, 5.2.1, 5.3.1, 6.1, 6.6
525GP
1.5, 5.1.5, 5.2.2, 5.3.3, 6.3
528G
1.5, 5.1.5, 5.2.1, 5.3.1, 6.2
529GP
1.5, 5.1.5, 5.2.2, 5.3.3, 6.3
5218GP
1.5, 5.1.5, 5.2.2, 5.3.1, 6.3
524NB(P)
1.1, 5.1.1, 5.2.1, 5.3.2, 6.1, 6.6
528NB
1.1, 5.1.1, 5.2.1, 5.3.2, 6.2
528NBP
1.1, 5.1.1, 5.2.2, 5.3.2, 6.3, 6.6
Page 9
1.1
A SERIES
The A Series multiport controllers are microprocessor-controlled units that allow one EIA-232C serial port on a computer to access up to 17 devices on a single unit and up to 96 devices by cascading units. Separate input/output buffers and UARTS enable the user to receive and transmit data simultaneously on all ports, and mix and match devices of different configurations. Port selection is accomplished through software control. The 524A(P) models have one host port and four peripheral ports. The 528A(P) models have one host port and eight peripheral ports. The Model 5218AP has one host port and seventeen peripheral ports. Figure 1 below shows a typical application using an A Series multiport controller.
Figure 1: A Series Application The serial port configuration (baud rates, word size, stop bits and parity) is userselectable for each individual port on all A Series models. In addition, the control character and XON/XOFF handshaking are programmable on the 528AP and 5218AP models. These features are easily programmed via the menu-driven configuration mode or by DIP switch settings (see Section 6). NOTE: The 524NB(P) and 528NB(P) models are virtually identical to the 524A(P) and 528A(P) models except they have no buffer and pass handshake lines through the unit (see Section 5.3.2). NOTE: The control character and XON/XOFF handshaking are options to order (Option 2 and Option 6 respectively) on the 524A(P), 524NB(P), and 528A models if the factory default values are not acceptable. The factory default control character is ASCII Control-T (14 hex) and XON/XOFF handshaking is disabled from the factory. Please contact BayTech for ordering information (See Section 8).
3
Page 10
1.2
AC11 SERIES
BayTech's AC11 Series multiport controllers connect directly to a host computer and provide multiplexing of messages from peripheral devices. Data is buffered until a terminating character is received indicating the end of a message or until the buffer is full. The messages are then sent to the host device preceded by a port identification number. The host device can select individual peripheral ports to transmit data to while simultaneously receiving messages from all peripheral ports. The 524AC11(P) models have one host port and four peripheral ports. The 528AC11(P) models have one host port and eight peripheral ports. The Model 5218AC11P has one host port and seventeen peripheral ports. Figure 2 on the following page shows a typical application using an AC11 Series multiport controller.
Figure 2: AC11 Series Application The serial port configuration (baud rates, word size, stop bits and parity) is userselectable for each individual port on all AC11 Series models. In addition, the message terminating character, the control character, and XON/XOFF handshaking are programmable on the 528AC11P and 5218AC11P models. These features are easily programmed via the menu-driven configuration mode or by DIP switch settings (see Section 6). NOTE: The control character and XON/XOFF handshaking are options to order (Option 2, and Option 6 respectively) on the 524AC11(P) and 528AC11 models if the factory default values are not acceptable. The factory default control character is ASCII Control T (14 hex) and XON/XOFF handshaking is disabled from the factory. Please contact BayTech for ordering information (see Section 8).
4