Page 25
Program Option Bar Code
Option
Alphanumeric Entry
Baud rate
Parity
300 BPS
00
600 BPS
01
1200 BPS
02
2400 BPS
03
4800 BPS
04
9600 BPS
05
19200 BPS
06
38400 BPS
07
None
00
Odd
01
Even
02
8 bits
00
7 bits
01
One bit
00
Two bits
01
Data bit
Stop bit
Exit
20
Page 26
Wand Emulation (for 8110/8150/8250) Bar/space polarity: High/low- Black will be transmitted as a high voltage level (+5) and space as low level (0V). Low/high- Black will be transmitted as a low voltage level (0V) and space as high level (+5). Initial polarity: You must make sure what is Initial polarity of your wand decode device in stand-by (idle). So, initial signal state as a High voltage level (+5) or Low voltage level (0V).
Program Option Bar Code
Option
Alphanumeric Entry
High/low
00
Low/high
01
Low
00
High
01
Bar/space polarity
Initial polarity
Exit
21
Page 27
Wand Emulation (for 8110/8150/8250) Output speed: This setting is same as serial transmission baud rate, and it must be approbated your wand decode resolution. The unit of speed is a width of minimum narrow bar. Margin delay: It is a timer of zone like space zone of barcode label margin. The width of margin time will be added before and after in each barcode data automatically when it is transmitted. Transmit delay: It is a delay time between barcode data output. It is the same as Block transmission delay of keyboard wedge.
22
Page 28
Program Option Bar Code
Option
Alphanumeric Entry
Output speed
620 pps
00
1250 pps
01
2500 pps
02
5000 pps
03
10000 pps
04
20000 pps
05
*pps: pixel per second 00
00
Reserved
Reserved 00-99 (10 pixel)
00-99 15
Margin delay 00-99 (10 msec)
00-99 30
Transmit delay
23
Exit
Page 29
Pin Assignments AS Series 8-pin RJ-45 Connector Pin
RS-232
Keyboard
1
VCC (+5V)
VCC (+5V)
2
TXD
NC
3
NC
CLK / PC
4
NA
DATA / PC
5
CTS
DATA / KB
6
RXD
NC
7
RTS
CLK / KB
8
GND
GND
1 2 3 54 6 7 8 9 10
1 2 3 5 46 7 8 8-pin
10-pin
AS Series 10-pin RJ-45 Connector Pin
RS-232
Keyboard
1
I/F
I/F
2
VCC (+5V)
VCC (+5V)
3
TXD
NC
4
NC
CLK / PC
5
GND
DATA / PC
6
CTS
DATA / KB
7
RXD
NC
8
RTS
CLK / KB
9
GND
GND
10
NC
GND
24
Page 30
Keyboard Wedge Combo Connector (To Host Side):
4
Pin
Mini-DIN 6P Male
DIN 5P Female
1
DATA / PC
DATA / KB
2
NC
NC
3
GND
GND
4
VCC (+5V)
VCC (+5V)
5
CLK / PC
CLK / KB
6
NC
NC
5
DIN 5P Female Connector
3 2
1
Mini-DIN 6P Male Connector
6
4
5
3
2
1
RS-232 DB-9F Connector (To Host Side): Pin
Definition
1
NC
2
TXD
3
RXD
4
NC
5
GND
6
NC
7
CTS
8
RTS
9
VCC (+5V)
25
5 4 3 2 1
9 8 7 6
Page 31
Keyboard Wedge PS/2 Connector (To Host Side): Pin
Mini-DIN 6P Male
Mini-DIN 6P Female
1
DATA / PC
DATA / KB
2
NC
NC
3
GND
GND
4
VCC (+5V)
VCC (+5V)
5
CLK / PC
CLK / KB
6
NC
NC
4
6
3
5
2 1
Mini-DIN 6P Female Connector
Mini-DIN 6P Male Connector
26
6
4
5
3
2 1
Page 32
27
Page 33
Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning. Alternate-The trigger button acts as a toggle switch. Press button to activate or stop scanning. Timeout off-The trigger button must be pressed to activate scanning, and scanner stops scanning when no code is decoded after the Stand-by duration elapsed. Continue-Scanner always keeps reading, and it does not matter when trigger button is pressed or duration is elapsed. Test only-For test of scan performance only. It is improper to be utilized to check the accuracy of transmitted data. Double read timeout: The scanner will require a several times successful decoding to confirm the data when enabled. The more confirming times required, the more inhibitive miss-reading code will be shown. The Multi field scan Enable function won’t be able to work if set Double confirm. Double confirm: If the barcode has been scanned twice, then only the first barcode will be accepted. Supplement Check Counter: It will be more reliable to read the barcode with extension (supplement) like UPCE/A or EAN-8/13, but slow down the decoding speed when this counter is set more.
28
Page 34
Program Option Bar Code
Option
Alphanumeric Entry
Scanning mode
Good-read off
00
Momentary
01
Alternate
02
Timeout off
03
Continue
04
Test only
05
01-99 (second)
00-99
06 Stand-by duration 01-99 (10 msec)
01-99
50 Double read timeout
Double confirm
00-99
00-09
(00: no double
00 confirm) 00-64
00-64
(verifications)
30
Supplement Check Counter
29
Exit