Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 13

Using the ArgoxScan 8110/8120/8150/8250/8310/8312: All Scanner Manual PN 49-81101-008.pdf, pages 25 to 34

Pages 25 to 34 of 123, from Using the ArgoxScan 8110/8120/8150/8250/8310/8312

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Argox AS-8150

Page 25

Program Option Bar Code

Option

Alphanumeric Entry

Baud rate

Parity

300 BPS

00

600 BPS

01

1200 BPS

02

2400 BPS

03

4800 BPS

04

9600 BPS

05

19200 BPS

06

38400 BPS

07

None

00

Odd

01

Even

02

8 bits

00

7 bits

01

One bit

00

Two bits

01

Data bit

Stop bit

Exit

20

Page 26

Wand Emulation (for 8110/8150/8250) Bar/space polarity: High/low- Black will be transmitted as a high voltage level (+5) and space as low level (0V). Low/high- Black will be transmitted as a low voltage level (0V) and space as high level (+5). Initial polarity: You must make sure what is Initial polarity of your wand decode device in stand-by (idle). So, initial signal state as a High voltage level (+5) or Low voltage level (0V).

Program Option Bar Code

Option

Alphanumeric Entry

High/low

00

Low/high

01

Low

00

High

01

Bar/space polarity

Initial polarity

Exit

21

Page 27

Wand Emulation (for 8110/8150/8250) Output speed: This setting is same as serial transmission baud rate, and it must be approbated your wand decode resolution. The unit of speed is a width of minimum narrow bar. Margin delay: It is a timer of zone like space zone of barcode label margin. The width of margin time will be added before and after in each barcode data automatically when it is transmitted. Transmit delay: It is a delay time between barcode data output. It is the same as Block transmission delay of keyboard wedge.

22

Page 28

Program Option Bar Code

Option

Alphanumeric Entry

Output speed

620 pps

00

1250 pps

01

2500 pps

02

5000 pps

03

10000 pps

04

20000 pps

05

*pps: pixel per second 00

00

Reserved

Reserved 00-99 (10 pixel)

00-99 15

Margin delay 00-99 (10 msec)

00-99 30

Transmit delay

23

Exit

Page 29

Pin Assignments AS Series 8-pin RJ-45 Connector Pin

RS-232

Keyboard

1

VCC (+5V)

VCC (+5V)

2

TXD

NC

3

NC

CLK / PC

4

NA

DATA / PC

5

CTS

DATA / KB

6

RXD

NC

7

RTS

CLK / KB

8

GND

GND

1 2 3 54 6 7 8 9 10

1 2 3 5 46 7 8 8-pin

10-pin

AS Series 10-pin RJ-45 Connector Pin

RS-232

Keyboard

1

I/F

I/F

2

VCC (+5V)

VCC (+5V)

3

TXD

NC

4

NC

CLK / PC

5

GND

DATA / PC

6

CTS

DATA / KB

7

RXD

NC

8

RTS

CLK / KB

9

GND

GND

10

NC

GND

24

Page 30

Keyboard Wedge Combo Connector (To Host Side):

4

Pin

Mini-DIN 6P Male

DIN 5P Female

1

DATA / PC

DATA / KB

2

NC

NC

3

GND

GND

4

VCC (+5V)

VCC (+5V)

5

CLK / PC

CLK / KB

6

NC

NC

5

DIN 5P Female Connector

3 2

1

Mini-DIN 6P Male Connector

6

4

5

3

2

1

RS-232 DB-9F Connector (To Host Side): Pin

Definition

1

NC

2

TXD

3

RXD

4

NC

5

GND

6

NC

7

CTS

8

RTS

9

VCC (+5V)

25

5 4 3 2 1

9 8 7 6

Page 31

Keyboard Wedge PS/2 Connector (To Host Side): Pin

Mini-DIN 6P Male

Mini-DIN 6P Female

1

DATA / PC

DATA / KB

2

NC

NC

3

GND

GND

4

VCC (+5V)

VCC (+5V)

5

CLK / PC

CLK / KB

6

NC

NC

4

6

3

5

2 1

Mini-DIN 6P Female Connector

Mini-DIN 6P Male Connector

26

6

4

5

3

2 1

Page 32

27

Page 33

Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning. Alternate-The trigger button acts as a toggle switch. Press button to activate or stop scanning. Timeout off-The trigger button must be pressed to activate scanning, and scanner stops scanning when no code is decoded after the Stand-by duration elapsed. Continue-Scanner always keeps reading, and it does not matter when trigger button is pressed or duration is elapsed. Test only-For test of scan performance only. It is improper to be utilized to check the accuracy of transmitted data. Double read timeout: The scanner will require a several times successful decoding to confirm the data when enabled. The more confirming times required, the more inhibitive miss-reading code will be shown. The Multi field scan Enable function won’t be able to work if set Double confirm. Double confirm: If the barcode has been scanned twice, then only the first barcode will be accepted. Supplement Check Counter: It will be more reliable to read the barcode with extension (supplement) like UPCE/A or EAN-8/13, but slow down the decoding speed when this counter is set more.

28

Page 34

Program Option Bar Code

Option

Alphanumeric Entry

Scanning mode

Good-read off

00

Momentary

01

Alternate

02

Timeout off

03

Continue

04

Test only

05

01-99 (second)

00-99

06 Stand-by duration 01-99 (10 msec)

01-99

50 Double read timeout

Double confirm

00-99

00-09

(00: no double

00 confirm) 00-64

00-64

(verifications)

30

Supplement Check Counter

29

Exit