Page 15

Programming the ArgoScan 8110/8120/8150/8250/8310/8312 To program the 8110/8120/8150/8250/8310/8312, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented.

To program each option, you must: 1. Scan the Program barcode on the parameter setting part. 2. Enter the option mode by scanning the Option Bar Code (also on the Parameter setting part). 3. To the right of the option barcode, the necessary alphanumeric inputs are listed. Scan these alphanumeric entries from the back fold out page. To confirm above steps, you must scan the Finish barcode on the back fold out page. 4. Once you have finished programming. Scan the Exit barcode, listed on the lower right hand corner of each parameter setting part.

10

Page 16

Program Barcode Program

Option Bar Code

Option

Alphanumeric Entry

Keyboard Wedge

00

Interface

RS-232

01 selection

Wand emulation

02

USB

03

Keyboard/RS-232

04

Auto detection Reserved

05

Exit Option Barcode

Back Fold Out Exit Barcode

Finish barcode

11

Page 17

Interface Selection This decoder built-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, wand emulation, and the latest USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. Interface selection: You can change factory interface default for other type interface. By plugging different cables, setting right interface, then the scanner will be changed to another interface. However, you must make sure which cable you need. Keyboard/RS232/UBS Auto detection: By setting this function, it will automatically select the Keyboard wedge or RS-232 or UBS interface for user.

Program Option Bar Code

Option

Alphanumeric Entry

Interface selection

Keyboard Wedge

00

RS-232

01

Wand emulation

02 (8110/8150/8250)

USB

03

Keyboard /RS232/USB

04

Auto detection Note:

-Default 12

Exit

Page 18

Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard Type: Select keyboard type connector of your host computer. Scanner must be selected to the appropriate host interface cable converter.

Program Option Bar Code

Option

Alphanumeric Entry

Keyboard type

IBM AT, PS/2

00

Reserved

01

Reserved

02

Reserved

03

Reserved

04

Reserved

05

Reserved

06

Exit

13

Page 19

Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard” to select country at “language” item. For details, please refer to your DOS or WINDOWS user’s manual. Keyboard Speed: By selecting, you can change output speed of scanner to match with host computer. Generally, set 00 or 01 in working high speed. If some output characters of barcode have been lost, you may need to set 05 or 06 to match your host keyboard speed. Function Key: Set Enable, scanner can output code as pressing function-key in your application program while the barcode datas contain ASCII value between 0116 to 1F16. Refer to ASCII table. Numeric Key: The Keypad has to be selected if your application program is only keypad numeric code acceptable. So, scanner will output code as press numeric keypad when it read numeric digit. (The keypad is in the right side of keyboard, and Num Lock control key is also on.) If Alt+Keypad is selected, the data characters will be transmitted as “Alt” + numbers. For example, when sending character “A”, the actual sending will be “Alt”+65. It is also useful when using non-English OS and keyboard layout.

Program Option Bar Code

Option

Alphanumeric Entry

14

Page 20

Keyboard layout

Keyboard speed

USA

00

Belgium

01

Danish

02

France

03

Germany

04

Italian

05

Portuguese

06

Spanish

07

Swedish

08

Switzerland

09

UK

10

Latin American

11

Japanese

12

0-8

00-08

0 : high clock rate

01 * (8150/8250)

8 : low clock rate

03 *(83XX/8120)

Disable

00

Enable

01

Alphabetic key

00

Numeric keypad

01

Function key

Numeric key

(Num lock state only) Alt+Keypad

15

02

Exit

Page 21

Keyboard wedge Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”, scanner can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on. Inter-character delay: This delay is inserted after each data characters transmitted. If the transmission speed is too high, the system may not be able to receive all characters. Adjust it and try out suited delay to make system work properly. Block transmission delay: It is a delay timer between barcode data output. The feature is used to transfer continually with shorter barcode data or multi-field scanning.

16

Page 22

Program Option Bar Code

Option

Alphanumeric Entry

Caps lock”ON”

00

Caps lock”OFF”

01

Disable

00

Enable

01

00-99 msec

00-99

Caps lock

Power-on simulation

02 Inter-character delay 00-99 10 msec

00-99 10

Block transmission delay

Exit

17

Page 23

RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII Code13 16) Flow control: None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol. RTS/CTS-If the scanner wants to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication. If there is no replied CTS signal from the host computer after the timeout (Response Delay) duration, the scanner will issue a 5 warning beeps. Xon/Xoff- When the host computer is unable to accept data, it sends a Xoff code to inform the scanner to suspend data transmission, and Xon to continue. ACK/NAK- When the ACK/NAK protocol is used, the scanner waits for an ACK (acknowledge) or (not acknowledge) from the host computer after data transmission, and will resend in response to a NAK. Inter-character delay: It is delay time between data character’s data output. It is also same as Inter-char. delay of keyboard wedge. Block transmission delay: It is a delay time between barcode data output. It is also same as Block transmission delay of keyboard wedge. Response delay: This delay is used for serial communication of the scanner to waiting for handshaking acknowledgment from the host computer.

18

Page 24

Program Option Bar Code

Option

Alphanumeric Entry

Flow control

None

00

RTS/CTS

01

Xon/Xoff

02

ACK/NAK

03

00-99 (msec)

00-99

00 Inter-character delay 00-99 (10 msec)

00-99

00 Block transmission delay 00-99 (100 msec)

00-99 20

Response delay

Exit

19