For the AMX Axcent3

Page 10

Installation

RS-232/RS-422/RS-485 connections FIG. 4 shows the RS-232/RS-422/RS-485 DB-9 (male) connector pinouts. The table below lists the connector pins, signal types, and signal functions. Pin 1

Pin 9 FIG. 4 RS-232/422/485 DB-9 (male) connector pinouts

DB-9 Pinouts

Wiring and Baud Configurations

Pin

RS-232

Signal

Function

1

RX-

Receive data

2

RXD

Receive data

X

3

TXD

Transmit data

X

4

TX+

Transmit data

5

GND

Signal ground

6

RX+

Receive data

RS-422

X

7

RTS

Request to send

X

8

CTS

Clear to send

X

9

TX-

Transmit data

RS-485

X

X (strap to pin 9)

X

X (strap to pin 6)

X X

X (strap to pin 4)

X

X (strap to pin 1)

The X’s show where to terminate the wires on the DB-9 connector.

Using the AXlink connector for data and power Connect the 4-pin AXlink connector to an external AXlink device, as shown in FIG. 5. PWR+

PWR+ AXP

AXP/TX AXM/RX

AXM GND-

GND-

External AXlink device

AXlink/PWR connector FIG. 5 AXlink/PWR data and power wiring diagram

Using the AXlink connector for data with a separate 12 VDC power supply Connect the 4-pin AXlink connector to an external AXlink device; connect the 2-pin PWR connector to the separate 12 VDC power supply as shown in FIG. 6. Make sure to connect only the PWR+ GNDPWR+ AXP/TX AXM/RX GND-

PWR+ AXP AXM GND-

Local 12 VDC power supply for ext. AXlink device

External AXlink device

Axcent3 FIG. 6 AXlink/PWR and optional 12 VDC power supply wiring diagram

6

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

Page 11

Installation

GND wire on the AXlink/PWR connector when using a separate 12 VDC power supply. Do not connect the PWR wire to the AXlink connector’s PWR (+) opening. Relay connections Connect up to eight independent external relay devices to the 16-pin RELAYS connector. Use A for common and B for output. Each relay is isolated and normally open. A metal connector strip is also provided to common multiple relays. 7

8 A

B

6 A

B

5 A

B

3

4 A

B

B

A

B

2 A

B

1 A

B

A

RELAYS

FIG. 7 RELAY 16-pin connector

IR/SERIAL/DATA connections Connect up to six IR, IR/Serial, and/or DATA (transmit only, 0 - 5 VDC levels only) devices to the 12-pin IR/SERIAL/DATA connector shown in FIG. 8. You can connect a CC-IRC Infrared Emitter, external serial device with a 2-pin captive-wire. You can also connect a data 0 - 5 VDC device. 6

5

4

3

2

1

IR / SERIAL / DATA

FIG. 8 IR/SERIAL/DATA 12-pin connector

Input/Output connections

GND

I/O1

I/O2

I/O3

I/O4

I/O5

12V

I/O6

Connect up to six Input/Output (I/O) devices to the INPUT/OUTPUT 8-pin connector, as shown in INPUT/OUTPUT 8-pin (male) connector section on page 7. A contact closure between GND and an I/O port is detected as a PUSH. When used for a voltage input, the I/O port detects a low (0 - 1.5 VDC) as a PUSH, and a high signal (3.5 - 5 VDC) as a RELEASE. When used for an output, each I/O port acts as a switch to GND and is rated at 200 mA @ 12 VDC.

INPUT / OUTPUT

FIG. 9 INPUT/OUTPUT 8-pin (male) connector

+12V - 12 VDC power output for PCS Power Current Sensors, VSS2 Video Sync Sensors, or similar I/O-type equipment I/O 1 - 6 - Six I/O ports GND - Common ground shared with I/O ports 1 - 6

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

7

Page 12

Installation

Program connector (front and rear panels) Connect a programming cable to the PROGRAM connector on the controller. The table below shows the DB-9 connector pins and signals for the PROGRAM connector. Use the PROGRAM connector to download Axcess programs, and to set up control communication options using the OpenAxcess software program. Program Connector and Pinouts Pin 1

Pin 9

Pin

Signal

2

RXD

3

TXD

4

+12 VDC

5

GND

7

+12 VDC

PROGRAM pins 1, 6, 8, and 9 are not used. Pins 4, 5, and 7 are for an ALF Programming Unit.

Axcess card slot connector (Axcent3 PRO only) FIG. 10 shows the 16-pin (male) connector that provides connection to the Axcess Control Cards. After installing control cards, refer to the literature provided with the control card for wiring and Axcess programming information.

SLOT 4

FIG. 10 Axcess Control Card 16-pin connector

8

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

Page 13

Axcess Programming

Axcess Programming Device and Channel Numbers The following table lists the port type, device numbers, channels, with a brief description. Device and Channel Number Parameters Port Type

Device Numbers

Channels

Description

RS-232/422/485

1-6

1 - 255

6 Rs-232/422/485 control ports with XON/XOFF(transmit on/ transmit off), and CTS/RTS (clear to send/ready to send), 300, 200 baud.

Relay

7

1-8

8-channel relay ports

IR/Serial/Data

8 - 13

1 - 254

6 IR/Serial/Data control ports that support high-frequency carriers up to 1.14 MHz, and one-way data, 300 - 38,400 baud (0 - 5 VDC)

Input/Output

14

1-6

6-channel I/O port for contact closure, 0 - 5 VDC voltage sensing, or interactive power sensing for IR ports

Axcess Control Cards

15 - 18

Card dependent

Card slots 1 - 4 (Axcent3 Pro only)

Send_Commands for RS-232/422/485 Ports The table below lists the Send_Commands for the internal RS-232/422/485 ports. Send_Commands for RS-232/422/485 Mode B9MOFF Sets the port’s communication parameters.

Sets the parameters for stop and data bits according to the software settings on the RS232 port (default). Syntax:

’B9MOFF’ Example:

SEND_COMMAND RS232_1,’B9MOFF’ Sets the RS-232 port settings to match the port’s configuration settings. B9MON Overrides the communication settings on the RS-232 port.

Overrides settings to 9 data bits and 1 stop bit, and use the port’s active baud rate settings. Example:

SEND_COMMAND RS232_1,’B9MON’ Resets the RS-232 port’s communication parameters to 9 data bits, 1 stop bit, and locks-in the baud rate set with the OpenAxcess software program.

CHARD Sets the delay time between transmitted characters.

Syntax:

’CHARD-<0-255>’ Variables: <0 - 255> = time in 100 microsecond increments Example:

SEND_COMMAND RS232_1,’CHARD-100’ Sets 10 millisecond delay between all transmitted characters.

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

9

Page 14

Axcess Programming

Send_Commands for RS-232/422/485 Mode (Cont.) CTSPSH Enables Pushes, Releases, and status information to send to the Program via channel 255.

Syntax:

’CTSPSH’ Example:

SEND_COMMAND RS232_1,’CTSPSH’ Sets the RS232_1 port to detect changes on the CTS input.

DE

A contact closure is sometimes called a debouncing circuit.

Sets the minimum delay time before controller detects/ responds to a contact closure and performs a programmed operation.

Syntax:

"’DE’,<Delay>" Variables: <Delay> = 0 - 255 in tenths of a second Example:

SEND_COMMAND IR_1,"’DE’, 20" Sets the IR_1 port’s minimum linked input stabilization time to 2 seconds.

Set Baud Set the RS-232/422/ 485 port’s communication parameters.

Syntax:

’SET BAUD (Baud),(Parity),(Data),(Stop),[485(DISABLE/ ENABLE)]’ Variables: Baud = 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 or AUTO Parity = N (none), O (odd), E (even), M (mark), S (space) Data = 7 or 8 data bits Stop = 1 or 2 stop bits Disable = disables RS-485 mode, and enables RS-422 Enable = enables RS-485 mode, and disables RS-422 Example:

SEND_COMMAND RS232_1,’SET BAUD 9600,N,8,1,485 ENABLE’ Sets the RS232_1 port’s communication parameters to 9,600 baud, no parity, 8 data bits, 1 stop bit, and enables RS-485 mode. Get Baud

The port sends the data through the master’s PROGRAM port.

Gets the RS-232/ 422/485 port’s current communication parameters.

Syntax:

’GET BAUD’ Example:

SEND_COMMAND RS232_1,’GET BAUD’ System response example:

Device 1, 38400,N,8,1 485 DISABLED ’HSOFF’

Disables hardware handshaking (default).

’HSON’

Enables hardware handshaking.

’RXCLR’

Clears all characters in the receive buffer waiting to be sent to the master.

’RXOFF’

Stops transmitting received characters to the master.

’RXON’

Transmits received characters to the master. The CREATE_BUFFER Axcess keyword automatically sends the RXON command to the device.

10

’TXCLR’

Clears and stops all characters waiting in the transmit buffer.

’XOFF’

Disables software handshaking (default).

’XON’

Enables software handshaking.

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

Page 15

Axcess Programming

Send_String Escape Sequences for RS-232/422/485 Ports The table below lists the Send_String escape sequences for the RS-232/422/485 ports. Send_String Escape Sequences for RS-232/422/485 Ports "27,17,<1-255>"

Sends a break character for the specified length of time. Variables: 1 - 255 = time in 100 microsecond increments

"27,18,1"

Sets the ninth data bit to 1 for all subsequent characters transmitted. Use this escape sequence with the ’B9MON’ command.

"27,18,0"

Clears the ninth data bit to 0 for all subsequent characters transmitted. Use this escape sequence with the ’B9MON’ command.

"27,19,<1-255>"

Inserts delay time before the next character transmits. Variables: 1 - 255 = time in 1 microsecond increments.

"27,20,0"

Sets RTS hardware handshake’s output high.

"27,20,1"

Sets RTS hardware handshake’s output low.

Send_Commands for IR/Serial/Data Ports The IR/Serial/Data Send_Commands listed in the table below generate control data for external device, and also configure the IR/Serial/Data ports. Send_Commands for the IR/Serial/Data Ports CAROFF

This command overrides active software settings.

Disables carrier from responding until a CARON command is received.

Syntax:

’CAROFF’ Example:

SEND_COMMAND IR_1,'CAROFF' Stops transmitting the IR carrier signal.

CARON

Syntax:

Enables the carrier to respond according to active software settings.

Example:

’CARON’ SEND_COMMAND IR_1,'CARON' Starts transmitting the IR carrier signal.

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

11

Page 16

Axcess Programming

Send_Commands for the IR/Serial/Data Ports (Cont.) CH Generates IR digit pulses to select a television channel number.

Channels 1-99 pulse as two digits. Channels 100 and greater, the one-hundredth digit pulses as 127. If IR function 21 (enter) exists, it follows the IR digit pulses. CTON sets the pulse length for each digit and CTOF sets the time between each digit or any other pulse. Syntax:

"’CH’,<channel>" Variables: <channel> = 0 - 199 Example:

SEND_COMMAND IR_1,"'CH',18" The controller performs the following: • Transmits IR pulses for 1 (IR code 11) for the time set by CTON. • Waits for the time set by CTOF. • Transmits IR pulses for the IR code for 8 (IR code 18) for the time set by CTON. • Waits for the time set by CTOF. If the IR code for ENTER (IR code 21) is programmed, steps 5 and 6 are performed. • Transmits IR pulses for ENTER (IR code 21) for the time set by CTON. • Waits for the time set by CTOF. CP Transmits IR code pulses and clear all commands in the buffer.

This command pulses the actual IR code. Pulse time is set by the CTON and CTOF commands. Syntax:

"’CP’,<channel>" Variables: <channel> = 0 - 252 Example:

SEND_COMMAND IR_1,"’CP’,2" Clears pending commands and pulses command number 2. CTOF Sets the single IR pulses off time between channel digits and IR functions.

CTOF sets the time between digits or any other pulse and CTON sets the pulse length for each digit. This is the time between digits, or pulses, that is associated with an SP command. Syntax:

"’CTOF’,<time>" Variables: <time> = 0 - 255 in tenths of a second; Time is stored in permanent memory. System default is 5 (.5 second). Example:

SEND_COMMAND IR_1, "'CTOF',10" Sets the channel's off-time pulse in tenths of a second. Default time is 5 (0.5 second). Time is stored in non-volatile RAM.

12

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

Page 17

Axcess Programming

Send_Commands for the IR/Serial/Data Ports (Cont.) CTON Sets the IR pulse (single) on time for each channel digit and IR functions.

CTON sets the pulse length for each digit and CTOF sets the time between digits or any other pulse. Syntax:

"’CTON’,<time>" Variables: <time> = 0 - 255 in tenths of a second; Time is stored in permanent memory. System default is 5 (.5 second). Example:

SEND_COMMAND IR_1, "'CTON',20" Sets the pulse length to 2 seconds. GET BAUD

The port sends the data through the master's PROGRAM port.

Gets the IR/Serial/ Data port's current communication parameters.

Syntax:

’GET BAUD’ Example:

SEND_COMMAND IR_1,'GET BAUD' System response example:

Device 1,38400,N,8,1 GET MODE Gets the IR/Serial/ Data port's current mode setting.

Syntax:

’GET MODE’ Example:

SEND_COMMAND IR_1,'GET MODE' System response example:

Device 8 IR,CARRIER,IO LINK 0 IROFF Stops IR output on the designated device.

Syntax:

’IROFF’ Example:

SEND_COMMAND IR_1,'IROFF' Stops transmitting IR signals. POD

Syntax:

’POD’ Disables current PON (power on) or POF (power off) command settings. Channel 255 changes are enabled. POF

Syntax:

’POF’ Sends IR function 28 (if available) or 9 to turn device power off. After three attempts, if the linked I/O channel still detects a power-on status, the controller starts processing stored buffer commands. Then, if another IR function 28 or 9 fails to turn the external device's power off, the controller sends a PUSH and RELEASE of channel 248 and generates a power failure error. If the device is turned on manually, this command turns the external device's power off unless a PON (power on) or POD (disable POF) command is received. Refer to the SET IO LINK command. PON

Syntax:

’PON’ Sends IR function 27 (if available) or 9 to turn device power on. After three attempts, if the linked I/O channel still detects a power-off status, the controller starts processing stored buffer commands. Then, if another IR function 27 or 9 fails to turn the external device's power on, the controller sends a PUSH and RELEASE of channel 248 and generates a power failure error. If the device is turned off manually, this command turns external device power on unless a POF (power off) or POD (disable 'PON' command) command is received.

Axcent3 and Axcent3 Pro Integrated Axcess Controllers

13

Page 18

Axcess Programming

Send_Commands for the IR/Serial/Data Ports (Cont.) PTOF Sets IR power-off pulse time after a power-on pulse in increments of .10 seconds.

Syntax:

"’PTOF’,<time>" Variables: <time> = 0 - 255; Time is stored in permanent memory. System default is 15 (1.5 seconds). Example:

SEND_COMMAND 55,"'PTOF',15" Sets the power-off pulse time after a power-on pulse to 1.5 seconds for device 55. PTON

Syntax:

Sets the IR power"’PTON’,<time>" on pulse time after Variables: a power-off pulse in <time> = 0 - 255; Time is stored in permanent memory. System default is 15 (1.5 increments of .10 seconds). seconds. Example:

SEND_COMMAND 55,"'PTON',15" Sets the power-off pulse time after a power-on pulse to 1.5 seconds for device 55. SET BAUD

Syntax:

Sets the IR/Serial/ Data port's communication parameters.

Variables:

’SET BAUD (Baud),(Parity),(Data),(Stop)’ Baud = 300 - 38,400 Parity = N (none), O (odd), E (even) Data = 7 or 8 data bits Stop = 1 stop bit Example:

SEND_COMMAND IR_1,'SET BAUD 9600,N,8,1' Sets the IR_1 port's communication parameters to 9,600 baud, no parity, 8 data bits, and 1 stop bit. SET MODE Sets the IR/Serial/ Data port for IR-, Serial-, or Datacontrolled devices that connect to the port.

Syntax:

’SET MODE (MODE)’ Variables: Mode = IR, SERIAL, or DATA Example:

SEND_COMMAND IR_1,'SET MODE IR' Sets the IR_1 port to IR mode so that an IR-controlled device can be connected to the port.

SET IO LINK

The I/O channel can sense 0-5 VDC using a PCS or PCS2 Power Current Sensor. Set the I/O channel to 0 to disable the link function.

Links an IR/Serial/ Syntax: Data port to an input/output (I/O) ’SET MODE (MODE)’ channel for use with Example: PON and POF commands. SEND_COMMAND IR_1,'SET IO LINK 1'

Sets the IR_1 port link to I/O port 1. The IR port uses the specified I/O input as power status for processing PON and POF commands.

14

Axcent3 and Axcent3 Pro Integrated Axcess Controllers