The text of a manual · part 1 of 4
Axcent3 and Axcent3 Pro Integrated Axcess Controllers Instruction Manual, pages 1 to 9
Pages 1 to 9 of 34
The original document is the PDF (485 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the AMX Axcent3
Page 1
instruction manual
3 Axcent and 3 Axcent Pro
Integrated Axcess Controllers
A x c e s s C e n t ra l C o n t r o l l e r s
Page 2
AMX Limited Warranty and Disclaimer AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: •
Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year.
•
Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year.
•
AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX Corporation does guarantee the control of dimmable loads that are properly connected to our lighting products. The dimming performance or quality cannot be guaranteed due to the random combinations of dimmers, lamps and ballasts or transformers.
•
Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year.
•
AMX Software is warranted for a period of ninety (90) days.
•
Batteries and incandescent lamps are not covered under the warranty.
This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer. All products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is obtained from the AMX RMA Department. The RMA number must be clearly marked on the outside of each box. The RMA is valid for a 30-day period. After the 30-day period the RMA will be cancelled. Any shipments received not consistent with the RMA, or after the RMA is cancelled, will be refused. AMX is not responsible for products returned without a valid RMA number. AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not liable for any claim made by a third party or by an AMX Dealer for a third party. This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX Corporation or an authorized representative of AMX Corporation has been advised of the possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury. Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full determination of rights. EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX CORPORATION MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX CORPORATION EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY.
Page 3
Table of Contents
Table of Contents Product Information .................................................................................................1 Specifications .................................................................................................................... 1
Installation .................................................................................................................3 Installing Axcess Control Cards (Axcent3 Pro Only) ......................................................... 3 Installing the Axcent3 into an Equipment Rack ................................................................. 3 Installing the AC-RK3 Rack Kit.......................................................................................... 3 Installing the CSB Cable Support Bracket......................................................................... 4 Wiring the Axcent3 ............................................................................................................ 5 Preparing and connecting captive wires .................................................................................. 5 RS-232/RS-422/RS-485 connections ...................................................................................... 6 Using the AXlink connector for data and power ....................................................................... 6 Using the AXlink connector for data with a separate 12 VDC power supply............................ 6 Relay connections.................................................................................................................... 7 IR/SERIAL/DATA connections ................................................................................................. 7 Input/Output connections ......................................................................................................... 7 Program connector (front and rear panels) .............................................................................. 8 Axcess card slot connector (Axcent3 PRO only) ..................................................................... 8
Axcess Programming ...............................................................................................9 Device and Channel Numbers .......................................................................................... 9 Send_Commands for RS-232/422/485 Ports.................................................................... 9 Send_String Escape Sequences for RS-232/422/485 Ports........................................... 11 Send_Commands for IR/Serial/Data Ports...................................................................... 11 Send_Commands for Input/Output Ports ........................................................................ 16 Standard IR Function Order ............................................................................................ 17 Program Port Commands................................................................................................ 18 Xmodem Timing Commands........................................................................................... 21 Setting PC-to-Axcess Program Communications, and a Controller’s Device Number in Terminal Emulator Mode ....................................................................................................... 21 Setting PC to Axcess Program Communications and Setting Device Number in Normal Mode...................................................................... 22 Axcess Master Mode....................................................................................................... 22
Replacing the Lithium Batteries ............................................................................25 Updating Firmware .................................................................................................27 Configuration ................................................................................................................... 27 Downloading Firmware.................................................................................................... 27
Axcent3 and Axcent3 Pro Integrated Axcess Controllers i
Page 4
Table of Contents ii
Axcent3 and Axcent3 Pro Integrated Axcess Controllers
Page 5
Product Information
Product Information The Axcent3 and Axcent3 Pro Integrated Axcess Controllers are multi-port Central Controllers that can be programmed to control RS-232/422/485, relay, IR/serial/data, and input/output devices. The Axcent3 Pro combines the multi-port functionality with 4 card slots that can be populated with Axcess Central Controller cards to accommodate system growth.
Specifications The following table lists the specifications for the Axcent3 and Axcent3 Pro. Specifications Dimensions (HWD): Axcent3
3.47" x 17.0" x 3.0" (88.1 mm x 432 mm x 76.2 mm)
Axcent3 Pro
3.47" x 17.0" x 13.65" (88.1 mm x 432 mm x 356.8 mm)
Weight: Axcent3 3
Axcent Pro
2.5 lbs (1.1 kg) 5.6 lbs (2.6 kg) without Axcess Control Cards
Power Requirement: Axcent3 3
Axcent Pro Memory:
• 500 mA @ 12 VDC (all relays energized) • 550 mA @ 12 VDC (without Axcess control cards) (all relays energized) • Volatile memory: 128Kbx16 (user-modifiable) • Non-volatile memory: 256Kbx16 (user-modifiable)
Enclosure
Metal with black matte finish
Input buffer
128 bytes
Output buffer (AXlink)
128 bytes
Supported baud rates
300, 600, 1200, 2400, 4800, 9600, 19200, 38400
Max. length of SEND_STRING to device
64
Max. Length of data packets from device
64
Front Panel Components: PROGRAM port
DB-9 (male) connector for system programming
Status indicators
32 red LEDs showing port activity: • RS-232/422/485 - 6 receive LEDs and 6 transmit LEDs • Relay - 8 LEDs • IR/Serial/Data - 6 LEDs • I/O - 6 LEDs
AXlink indicator
Green LED shows AXlink data activity. Blink patterns include: • Off - No power, or the controller is not functioning properly • 1 blink per second - Normal operation. Device numbers match the programmed device numbers in the Axcess program. • 2 blinks per second - Device numbers do not match the Axcess program, a device is not present, or a device is not set to the right number. • 3 blinks per second - AXlink bus error. Check all AXlink bus connections. • Full On - Axcess program is not present and there is no AXlink activity
Slots 1 - 4 RS-232 Range:
4 Axcess Control Card slots (Axcent3 Pro only) 50’ (15.24 m) max.
Axcent3 and Axcent3 Pro Integrated Axcess Controllers
1
Page 6
Product Information
Specifications (Cont.) Rear Panel Components: RS-232/RS-422/RS-485 ports
Six 9-pin (male) D-sub, RS-232/422/485 XON/XOFF, CTS/RTS, 300, 200 baud
Status indicators
32 red LEDs that show RS-232/422/485, relay, IR/Serial/Data, and I/O port activity. The LEDs light when data activity occurs on the associated ports.
AXlink indicator
Green LED showing power and AXlink data activity.
AXlink/PWR connector
4-pin connector for AXlink data and power, and 2-pin connector for external 12 VDC power supply
RELAYS connector
Two 8-pin connectors, 750 mA, 28 VAC/24 VDC (normally open)
IR/SERIAL/DATA connectors
12-pin (6 two-pins) male connector that supports IR, IR/Serial or one-way data communication (0 - 5 VDC levels only)
Input/Output connectors
8-pin connector, I/O 1 - 6, Common, +12 VDC power tap 200 mA, contact closure or TTL logic inputs
PROGRAM port
DB-9 (male) connector for system programming and diagnostics
Slots 1 - 4
Four 16-pin connectors for Axcess Control Cards (Axcent3 Pro only)
Included Accessories:
• 4 CC-IRC emitters • Metal tab strip for commoning relays • Rack-mount brackets
Optional Accessories:
• 12 VDC power supply • CSB Cable Support Bracket • AC-RK3 Rack Kit • Axcess Control Cards (Axcent3 Pro only)
2
Axcent3 and Axcent3 Pro Integrated Axcess Controllers
Page 7
Installation
Installation Installing Axcess Control Cards (Axcent3 Pro Only) To install Axcess Control Cards: 1. Discharge the static electricity from your body, by touching a grounded object. 2. Remove the thumbscrews and faceplate from the front panel (FIG. 1). Removable faceplate
RS-232 / 422 / 485
RELAYS
IR / SERIAL DATA
TX 1
2
3
1
2
3
I/O
4
5
6
1
2
3
4
1
2
3
1
2
3
4
5
6
5
6
7
8
4
5
6
4
5
6
RX AXlink
PROGRAM
Thumbscrews FIG. 1 Axcent3 Pro
3. Install up to 4 Axcess Control Cards component-side up into SLOT 1 - SLOT 4. 4. Replace the faceplate and secure with the thumbscrews.
Installing the Axcent3 into an Equipment Rack Use the rack-mounting brackets supplied with each controller for equipment rack installations. Remove the mounting brackets for flat surface installations. 1. Discharge the static electricity from your body by touching a grounded object. 2. Place the controller into the equipment rack, and align the mounting bracket holes with the mounting holes on the equipment rack. Start the mounting screws on both sides of the controller and tighten. 3. Connect the data cables into the controller. 4. Connect the power cable to the AXLINK/PWR connector to power-up the controller.
Installing the AC-RK3 Rack Kit Use the optional AC-RK3 Rack Kit for rear equipment rack rail installations or to place the controller 6 inches from the front/rear of the equipment rack. You need a Phillips-head screwdriver. 1. Discharge the static electricity from your body by touching a grounded object. 2. Remove the rack-mount brackets supplied with the controller. 3. Install the AC-RK3 brackets with the supplied Phillips-head screws. Align the bracket holes with the mounting brackets on the equipment rack. Then, start the mounting screws on both sides of the controller and tighten (see FIG. 2).
Axcent3 and Axcent3 Pro Integrated Axcess Controllers
3
Page 8
Installation
Mounting screw holes
AC-RK3 Rack Kit mounting brackets
Mounting Configurations
Front
Front
FIG. 2 AC-RK3 Rack Kit mounting diagram
4. Connect the data cables into the controller. 5. Connect the power cable to the AXLINK/PWR connector to power-up the controller.
Installing the CSB Cable Support Bracket Install the optional CSB Cable Support Bracket to secure the power and data cables connected to the controller. You can use the CSB with the supplied rack mounting brackets or optional AC-RK3. You need a Phillips-head screwdriver. 1. Discharge the static electricity from you body by touching a grounded object. 2. Disconnect all (if applicable) power and data cables from the controller. 3. Hold the controller in place, and remove the mounting hardware from the equipment rack. Then, carefully remove the controller from the rack and place it onto a flat surface. 4. Install the CSB, as shown in FIG. 3.
4
Axcent3 and Axcent3 Pro Integrated Axcess Controllers
Page 9
Installation
CSB Cable Support Bracket
Mounting screws
2", 4", 6" Mounting Configurations 2"
4"
6"
Mounting screws
FIG. 3 CSB mounting diagram
5. Align the bracket holes with the mounting brackets on the equipment rack. Then, start the mounting screws on both sides of the controller and tighten. 6. Connect the data cables into the controller. Then, secure the data cables to the CSB. 7. Connect the power cable to the AXLINK/PWR connector to power-up the controller. Then, secure the cable to the CSB.
Wiring the Axcent3 Each connector you use to control external devices must be wired according to the information in this subsection. Preparing and connecting captive wires 1. Strip 0.25 inch of wire insulation off all wires. 2. Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types. 3. Turn the flat-head screws clockwise to secure the wire in the connector. Do not over-torque the screw; doing so can bend the seating pin and damage the connector.
Axcent3 and Axcent3 Pro Integrated Axcess Controllers
5