Page 71
Ping USB Server The Ping USB Server function allows you to detect a USB server connected to the USB port.
Hardware Tests The Hardware Tests function performs tests on the various M7100 hardware.
Note: These hardware tests are for our own internal testing and may, or may not, display as failed for the end user, even though the unit is running fine.
67
Page 72
Local Settings, Laser & CCD Only Note: For instructions on setting the 2D Area Imager see Local Settings, Imager Only. The “Local Settings” function sets much of the M7100 handheld terminal’s internal hardware and software.
Barcode Options The “Barcode Options” function allows you to make changes to the way specific bar codes are scanned by the internal scan engine.
Symbology Settings The “Symbology Settings” function allows you to make changes to each individual bar code.
68
Page 73
Setting the Code 39 Bar Code The individual bar codes can be enabled and disabled by hitting the [Space] key. Only enabled bar code symbologies can be modified. To modify a bar code symbology hit the [ENTER] key while the bar code name is highlighted.
CODE 39 DECODER ON*
Enable reading Code 39 bar codes.
OFF
Disable reading Code 39 bar codes.
FULL ASCII ON
Enable the Full ASCII Extension to Code 39. This allows the scanner to read upper and lower case characters as well as extended special characters.
OFF* Disable the Full ASCII Extension to Code 39. This sets the reader to the standard Code 39 mode. MOD 43 CHECK DIGIT ON
Enable the Mod 43 Check Digit for Code 39. When this option is enabled, only Code 39 labels that contain a valid check digit will be read.
OFF* Disable the Mod 43 Check Digit. Check digit verification will not be performed. SEND CHECK DIGIT ON
Transmit the Mod 43 Check Digit with the bar code data. Requires the “Mod 43 Check Digit” option above to be set on.
OFF* Do not transmit the Mod 43 Check Digit. CONCATENATE MODE
69
Page 74
ON
Enable Concatenate Mode. The concatenate mode allows the M7100 handheld terminal to accumulate multiple bar codes in its buffer and then sends them to the computer just like they were a single bar code. When a Code 39 label containing a leading space is read, the M7100 emits two short beeps and buffers the data without transmission. This process continues until a Code 39 label without a leading space is read or 128 characters are buffered. A Code 39 bar code label that only contains a single or multiple dashes (minus sign) will clear the buffer.
OFF* Disable Concatenate Mode.
Setting the UPC Bar Code
UPC DECODER ON*
Enable reading UPC-A and UPC-E bar codes.
OFF
Disable reading UPC-A and UPC-E bar codes.
CONVERT UPC-E TO UPC-A ON
Convert all UPC-E labels to their UPC-A equivalents before transmission. After conversion, the reader will follow the UPC-A programming options.
OFF* No conversions will be performed. CONVERT UPC-A TO EAN-13 ON
Convert all UPC-A labels to an equivalent EAN-13 format by inserting a leading zero. After conversion, the reader will follow the EAN-13 programming options.
OFF* No conversions will be performed. SEND UPC-A NUMBER SYSTEM 70
Page 75
ON*
Transmit the UPC-A Number System character.
OFF
Do not transmit the UPC-A Number System character.
SEND UPC-E NUMBER SYSTEM ON*
Transmit the UPC-E Number System character.
OFF
Do not transmit the UPC-E Number System character.
SEND UPC-A CHECK DIGIT ON*
Transmit the UPC-A Check Digit character.
OFF
Do not transmit the UPC-A Check Digit character.
SEND UPC-E CHECK DIGIT ON*
Transmit the UPC-E Check Digit character.
OFF
Do not transmit the UPC-E Check Digit character.
Setting the EAN Bar Code
EAN DECODER ON*
Enable reading EAN-8 and EAN-13 bar codes.
OFF
Disable reading EAN-8 and EAN-13 bar codes.
ZERO FILL EAN-8 TO EAN-13 ON*
Add five leading zeros to EAN-8 labels. After conversion, the reader will follow the EAN-13 programming options.
OFF
No conversions will be performed. 71
Page 76
SEND EAN-13 COUNTRY CODE ON*
Transmit the EAN-13 Country Code.
OFF
Do not transmit the EAN-13 Country Code.
SEND EAN-8 COUNTRY CODE ON*
Transmit the EAN-8 Country Code.
OFF
Do not transmit the EAN-8 Country Code.
SEND EAN-13 CHECK DIGIT ON*
Transmit the EAN-13 Check Digit character.
OFF
Do not transmit the EAN-13 Check Digit character.
SEND EAN-8 CHECK DIGIT ON*
Transmit the EAN-8 Check Digit character.
OFF
Do not transmit the EAN-8 Check Digit character.
ISBN CONVERSION ON
Convert 13 DIGIT BOOKLAND/EAN (978) prefix to its corresponding 10-digit ISBN number.
OFF* Do not convert Bookland/EAN to an ISBN number.
UPC/EAN Supplements Settings
SUPPLEMENTS DECODER ON
Enable reading UPC, EAN & Bookland supplements. 72
Page 77
OFF* Disable reading UPC, EAN & Bookland supplements. ALLOW 2 DIGIT ON*
Enable reading 2 digit supplements. Option 0) above must be set on.
OFF
Disable reading 2 digit supplements.
ALLOW 5 DIGIT ON*
Enable reading 5 digit supplements. Option 0) above must be set on.
OFF
Disable reading 5 digit supplements.
REQUIRE UPC SUPPLEMENTS ON*
Enable reading UPC supplements. Option 0) above must be set on.
OFF
Disable reading UPC supplements.
REQUIRE EAN SUPPLEMENTS ON*
Enable reading EAN supplements. Option 0) above must be set on.
OFF
Disable reading EAN supplements.
REQUIRE BOOKLAND SUPPLEMENTS ON*
Enable reading Bookland supplements. Option 0) above must be set on.
OFF
Disable reading Bookland supplements.
SEND SEPARATOR SPACE ON
Inserts a space between the standard bar code data and the supplemental data. OFF* No separator space is inserted.
73
Page 78
Setting the I - 2 of 5 Bar Code
INT 2 OF 5 DECODER ON*
Enable reading Interleaved 2 of 5 bar codes.
OFF
Disable reading Interleaved 2 of 5 bar codes.
USS CHECK DIGIT Specifies if the USS check digit type will be used with Interleaved 2 of 5: ON
Uniform Symbology Specification (3-1-3 mod 10)
OFF* None (no check digit required) OPCC CHECK DIGIT Specifies if the OPCC check digit type will be used with Interleaved 2 of 5: ON
Optical Product Code Council (2-1-2 mod 10)
OFF* None (no check digit required) SEND CHECK DIGIT ON
Transmit the Interleaved 2 of 5 check digit with the bar code data.
OFF* The check digit is not transmitted. FIXED LENGTH ON
Read only Fixed Length Interleaved 2 of 5 bar code labels that match the lengths defined in “Set Fixed Length #1 - #3” options below. The check digit can be on or off.
74
Page 79
OFF* Disable Fixed Length mode. Read all Interleaved 2 of 5 labels without regard to length. SET FIXED LENGTH #1 (02-60) Sets the first valid Fixed Length for Interleaved 2 of 5. Enter a two-digit value to enter the length. Valid lengths are 02 to 60 characters. By definition, the lengths of Interleaved 2 of 5 labels are an even number of characters. The default Fixed Length is 2 characters. SET FIXED LENGTH #2 (02-60) Sets a second valid Fixed Length for Interleaved 2 of 5. Enter a two-digit value to enter the length. The default length is set to 6 characters. SET FIXED LENGTH #3 (02-60) Sets a third valid Fixed Length for Interleaved 2 of 5. Enter a two-digit value to enter the length. The default length is set to 6 characters.
Setting the Codabar Bar Code
CODABAR DECODER ON * Enable reading Codabar bar codes. OFF
Disable reading Codabar bar codes.
SEND START/STOP ON
Transmit the Codabar start/stop characters.
OFF * Do not transmit the Codabar start/stop characters. CLSI FORMATTING
75
Page 80
ON
The reader will insert a blank after the 1st, 5th, and 10th characters of a 14-character Codabar label. The label length does not include the start and stop characters.
OFF * Disable CLSI formatting. CLSI CHECK DIGIT ON
Enable the CLSI check digit. When this option is enabled, all fourteen digit numeric bar codes must contain a valid check digit.
OFF* Disable the CLSI check digit. Check digit verification will not be performed.
Setting the Code 128 Bar Code
CODE 128 DECODER ON * Enable reading Code 128 bar codes. OFF
Disable reading Code 128 bar codes.
UCC-128 VERIFICATION ON
A valid Mod 10 Check Digit is required on UCC-MOD 10 bar codes. (Applies to 20-digit serial shipping container bar codes.)
OFF * UCC-MOD 10 bar codes are accepted without valid Mod 10 Check Digits. SEND MOD 10 CHECK DIGIT ON * Transmit the Mod 10 Check Digit with the bar code entry. OFF
Do not transmit the Mod 10 Check Digit.