Page 21

GSM/GPRS Network Card Support The AML M7100 now supports GSM/GPRS network cards. When a GPRS network card comes installed in the M7100, the menus will be slightly different from the standard menus. To determine if the unit has the correct firmware installed. Use the M7100 Menu System and select “Diagnostic Menu > Firmware Versions” and see under RAM DISK IMAGE the version 1.3.0-32 firmware.

Installing the GPRS SIM Card The M7100 GSM/GPRS card requires a customer supplied SIM (Subscriber Identity Module) card issued by the cellular network Access Provider (e.g. T-Mobile, Cingular or Verizon). This card must be installed prior to using the M7100 GSM/GPRS system. 4. Push metal door up to release then rotate the SIM door open.

3. Carefully pull GSM/GPRS card straight out of terminal. Note the orientation of card when replacing it back into unit.

2. Pull RF cap down slightly, and then out from body of terminal.

5. Note the location of the beveled corner on SIM card with metal contacts pointing out.

6. Close SIM cover and push down to lock SIM card into place.

1. Remove the 2 screws holding on RF end cap.

17

Page 22

To review the GSM/GPRS settings, use the M7100 Menu System and select “Network Setup > Net I/F Settings” and see the settings main screen.

The settings are selected by highlighting the proper item and hitting the [ENTER] key. The information below is an example of how the unit might be set, your settings may be different. Contact your local GSM/GPRS cellular service provider for information on these settings.

18

Page 23

Typical Values for the “GSM/GPRS Settings”: APN – Access Provider Name The character string specifying the cellular service provider (e.g. internet2.voicestream.com). Port – Linux port name This is a character string specifying the port name (usually “/dev/ttyS0”). Baud Rate – Transmission Baud Rate This is a character string specifying the baud rate (usually 115200). Init String – Initialization String The character string sent to the internal GPRS modem card prior to initiating a call. Hangup String – Disconnection String The character string sent to the internal GPRS modem card when it disconnects from a call. Dial String – Dialing string The character string sent to the internal GPRS modem card to initialize dialing of the call. Timeout – Connection Timeout value This is a numeric string that determines the amount of time (in seconds) to wait for the call to connect. Extra Settings – Extra settings string This is a character string that is sent to the internal GPRS modem card prior to initiating a call that may be used in special circumstances. One example is sending manufacturer specific startup strings.

19

Page 24

To determine if the GSM/GPRS card is functioning properly, use the M7100 Menu System and select “Network Setup” and one of the following screens should appear:

Connection Failed!

If the screen does not say “STAT: Connected” then you are out of range of a GSM/GPRS Cellular Network, or you have the GSM/GPRS modem settings wrong. To determine the amount of data being sent by the GSM/GPRS card, use the M7100 Menu System and select “Diagnostics > RF Link Status” and see the “Network Status GSM/GPRS”.

GSM/GPRS Error Messages There are numerous error messages that may appear. These error messages are logged on the M7100 by the “syslog” system and stored in the volatile file named “var/log/messages”.

20

Page 25

The Optional M7100 Handle The M7100 has an optional “pistol grip” style handle for users who prefer the point and shoot style. The M7100 handle is secured to the M7100 handheld terminal by 4 screws. The battery is then relocated in the handle for easy change-out.

Installing the Optional M7100 Handle To install the M7100 handle, remove the M7100 battery cover and store in a safe place. Remove the M7100 battery and set it aside. Remove only the 2 screws in the bottom of the battery compartment. The M7100 Handle comes with the necessary 4 screws to secure it to the M7100 unit. Do not over-tighten the 4 screws. Once the handle is securely fastened, insert the battery into the bottom of the handle with the contacts towards the M7100 handle. The battery is held into place by the spring latch. Install the battery handle door on the bottom of the handle. Never use the M7100 handle without the battery door in place.

21

Page 26

The M7100 Communications Ports The M7100 has three types of communications ports on the bottom of the unit. The three ports are shown here.

1

2

4

3

1

2

10 9 8 7 6 5 4 3 2 1

Description of the Infra-Red Detector Array Port (IrDA) 1. IrDA in (right side of window) 2. IrDA out (left side of window)

Description of the RJ-45 10 Pin Connector (RS-232) 1. 5 VDC (out to handheld tethered scanner) 2. RxD (in to terminal) 3. TxD (out from terminal) 4. RTS (out from terminal) 5. GND 6. Battery Charge (in to terminal) 7. CTS (in to terminal) 8. UDC+ (USB data +) 9. UDC – (USB data -) 10. Battery Out (from terminal) Note: the Battery Out is only active when the unit is set to IrDA w/RS232 Scanner or IrDA w/RS232 Comms

Note: A standard 8-pin Ethernet connector can be used to connect the M7100 to an RS-232 serial port printer. In this case the 2 outside pins (1 and 10) are not connected. Use the chart and example on the right to determine the pin-out.

Description of the USB Type II Connector (Slave only) 1. 5 VDC 2. Data 3. Data + 4. GND

22

1. 2. 3. 4.

RxD (in to terminal) TxD (out from terminal) RTS (out from terminal) GND

Page 27

The M7100 Cradle The M7100 Handheld Terminal has available, an optional charging and communications cradle. The cradle automatically charges the M7100 battery while it is resting in the cradle. The cradle also includes an extra slot to charge a spare battery. The M7100 cradle can accommodate the M7100 with or without the optional M7100 handle.

The M7100 Cradle has three indicator lights: POWER - Indicates that the M7100 Cradle is plugged in. MAIN - Indicates the M7100 main battery is charging. SPARE - Indicates the spare battery is charging. When the battery charging LED is red, the battery is charging. When the battery charge LED is green the battery is fully charged. A fully discharged battery takes about 6 hours to completely recharge.

23

Page 28

The M7100 Cradle’s Communication Ports The M7100 handheld terminal has 2 different styles of communications ports, RS-232 (RJ-45) and USB (Type II). The M7100 Cradle also has 2 communications ports, RS-232 (DB-9) and USB (Type II). The M7100 Communications Cradle uses a standard RS-232 (DB-9 Male – DB-9 Female) cable.

Both communication connectors on the back of the M7100 cradle are wired “straight through”. This means that the communications settings on the M7100 handheld terminal will determine the settings on the communication cradle. The M7100 Cradle has no internal or external settings that can be changed. The slower RS-232 communication port is primarily used for uploading and downloading of data files to the M7100 Batch handheld terminal. File transfers for the M7100 RF handheld terminal can be done using FTP. For more information on FTP see the “FTP” section of this manual. The high speed USB data port is used to load a new or updated operating system into the M7100 handheld terminal only. Use the AML USB Flash utility software to load the operating system. DB-9 Pin out (RS-232) 1 – DCD (Data Carrier Detect)

6 – DSR (Data Set Ready)

2 – RXD (Receive Data)

7 – RTS (Request To Send)

3 – TXD (Transmit Data)

8 –CTS (Clear To Send)

4 – DTR (Data Terminal Ready)

9 – NC (No Connection)

5 - GND (Signal Ground)

24

Page 29

3

Chapter

The M7100 RF Server Login This chapter describes the login functions of the M7100 terminal. It also describes using Telnet and Terminal Emulation support.

W arning: If the M7100 Handheld Terminal has improper security and/or network settings, the terminal will fail to connect to any network devices. For help see the Network Settings section of this manual.

The CommandLink™ Software The CommandLink™ software allows a Windows based PC to become an RF server. An RF server is a master control PC that tells the M7100 handheld terminal what to display and what to do with collected data. If your network already has an RF server then you may choose to login into that server. Many servers use a Telnet session to connect them to their client devices. By default, the M7100 starts a telnet session when it is first turned on. For more information about telnet, see the Telnet section of this chapter.

Wait WLAN The following screen shows the M7100 handheld terminal waiting to find a Wireless Local Area Network (WLAN).

25

Page 30

If there is not a wireless Access Point (AP) for the handheld terminal to connect to, then the terminal will not proceed past this point. For help in determining the presence and strength of an Access Point’s transmission see the Network Diagnostics section of this manual.

Connecting The following screen shows the M7100 handheld terminal connected to an Access Point. The MAC address number for the access point is displayed at the bottom of the screen. After the M7100 handheld terminal connects (associates) with an access point, it attempts to connect to an active CommandLink™ Server.

Note: If there is not an RF Server active for the M7100 handheld terminal to connect to, then the terminal will not proceed past this point!

Login The following graphic shows a typical login screen for the CommandLink™ RF server. If you are using your own server, the login screen will be different. For help in determining the presence of a CommandLink™ Server see the CommandLink™ documentation.

If the User ID or Password is not listed on the CommandLink™ database a Login Error screen will appear.

26