The text of a manual · part 12 of 14
M7100 Wireless Handheld Terminal User's Guide, pages 111 to 120
Pages 111 to 120 of 131
The original document is the PDF (4.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the AML M7100
Page 111
The purpose of the laser aim is to be able to tell where the laser beam is pointing when scanning bar codes that are a long way away from the unit. The laser point helps to locate the beam before the laser starts rastering. Once the laser starts rastering, the bar code will be scanned. Laser Timeout
Turns off Laser / CCD after (1 – 9) seconds when the trigger is pushed in Pulse mode, or held down in Trigger mode. The laser / CCD will always turn off immediately after a good read.
Read Verify
Performs bar code re-reads the number of times (0 – 9) required for applications where accuracy is critical. This is used where the bar code is poorly printed or damaged.
Imager Options (2D Imager Only)
These options are used to configure the 2D Imager device behavior, and the trigger mode for the M7100 handheld terminal. Trigger Mode Trigger
Trigger activates scanning device for as long as trigger is held up to the Laser Timeout value in seconds. (Recommended)
Pulse
Continues to keep the scanner active even when the trigger is not held down, up to Laser Timeout value in seconds.
Laser Timeout
Turns off Laser / CCD after (1 – 9) seconds when the trigger is pushed in Pulse mode, or held down in Trigger mode. The laser / CCD will always turn off immediately after a good read.
Aim Time (mS)
The amount of time the green LED aiming beam is on. The purpose of the LED aiming beam is to be able to locate where the center of the LED beam is pointing when scanning bar codes 107
Page 112
that are a long way away from the unit. The Green LED box helps to locate the center of the Red LED beam when the Centering box below is checked. Once the Green LED beam turns off, the bar code will be scanned. LED Power
Adjust the intensity of the LED light (in percent, 100 = 100%). In brightly lit areas the LED light may not be necessary. Reducing the amount of LED light can increase battery life.
Red LED Light Checked* Unchecked
Enable the Red LED illumination light. Disable the Red LED illumination light.
Centering Checked Unchecked* Image Contrast
Allows the unit to look for the bar code to be scanned in the middle of the Red LED illumination beam only. Disable the Red LED illumination light.
Determines the normal contrast for the Matrix bar code image that is being scanned. If the bar code image is typically light, a setting of 2 would be best. If the bar code image is typically dark, then a setting of 6 would be best.
Bar Code Edit Options The “Barcode Edit Options” allows data editing (modification) before transmission.
Enable Bar Code Edit Check-box must be checked for any of the editing options below to be valid. ON:
Enable Data Editing.
OFF*: Disable Data Editing.
108
Page 113
Code Type Refers to the type of bar codes for which editing can be enabled, allowing editing to be specific to a type of bar code. The choices are listed below: All Barcodes* Code 39 EAN-13 Codabar MSI/Plessey
UPC-A EAN-8 Code 128 Code 11
UPC-E Int 2 of 5 Code 93 ISBN
Strip Leading Characters (0-9, A-F) Refers to the number (0-15) of characters to be stripped or removed from the beginning of the bar code data. Strip Trailing Characters (0-9, A-F) Refers to the number (0-15) of characters to be stripped or removed from the end of the bar code data. NOTE: If the total number of strip characters (both Leading and Trailing) is greater than the number of characters of the bar code, no characters will be stripped. Strip Lead/Trail Spaces ON:
Any Leading and Trailing Spaces will be stripped from the data.
OFF*: No spaces will be stripped. Preamble This function will allow you to add a fixed string to the beginning of the bar code. Postamble This function will allow you to add a fixed string to the ending of the bar code. Code Type Refers to the type of bar codes for which the preamble or Postamble will be applied. The choices are listed below: All Barcodes* Code 39 EAN-13 Codabar MSI/Plessey
UPC-A EAN-8 Code 128 Code 11 109
UPC-E Int 2 of 5 Code 93 ISBN
Page 114
Beep Options The following settings determine what tone and duration the M7100 beeper will perform after a good bar code scan. You must save the settings for them to take effect.
Saving Bar Code Settings You must either save your setting or you can restore the default settings for all bar code options.
The 2D Imager settings are quite extensive and complex. Usually the default settings are satisfactory for most applications. If the bar code settings have been dramatically changed, the operator can use the <Restore Defaults> function to return the settings to factory defaults. Refer to the “HHP® IMAGETEAM™ OEM Engine User’s Guide” for a more technical description of the 2D Imager settings. 110
Page 115
Date/Time The “Date/Time” function sets the M7100 handheld terminal’s internal clock. These setting are saved even if the unit is powered off.
You can hit the [ENTER] key to pop-up a calendar to make setting the date easier. You must “Save” the settings for them to take effect.
Port Configuration The “Port Configuration” function allows the operator to configure the local serial port.
111
Page 116
Port: IrDA Printer Only
All printer data will be sent out the Infrared port only. No data will be sent out the RS-232 port.
RS232 Printer Only
All printer data will be sent out the RJ-45 wired RS-232 port. No data will be sent out the IrDA port.
IrDA w/ RS232 Scanner
The printer data will be sent out the IrDA port while the RJ-45 wired RS-232 port will be used for a tethered (corded) scanner.
Whenever the RS-232 port is selected, you must set up the port parameters. Baud:
115200 – 57600 – 38400 – 19200 – 9600 – 4800 – 2400 – 1200 - 300
Parity:
None – Even – Odd - Mark
Data Type:
None,8,1 – Even,8,1 – Odd,8,1 – None,7,1 – Even7,1 - Odd,7,1 None,7,2 – Even,7,2 – Odd,7,2 – None,8,2 – Even,8,2 – Odd,8,2
Flow Control: <Save>
None - RTS/CTS – Xon/Xoff You must save the settings for them to take effect.
112
Page 117
Startup Options The “Startup Options” function allows the operator to setup various options used when the M7100 is first powered on.
Start Dir:
This is the directory that the M7100 terminal will use for any autostart programs.
Start Prog:
This is the program the M7100 will automatically start when the unit is powered on. When a startup program is specified, the M7100 will not start the internal telnet program.
Start Param:
These are any optional settings that the auto-start program will use when started.
Network Delay:
This is the delay in milliseconds the M7100 will wait before starting the auto-start program. This gives the network time to setup routers and RF data paths to the M7100.
Enable Servers This allows you to disable network connectivity to the M7100. This is usually used to keep the M7100 more secure over a network. Disabling these functions can prevent terminal emulation functionality as well as file transfers and operating system updates. FTP Server:
The FTP server allows files to be transferred to and from the terminal over the RF link. Do not disable the FTP server function if you are using a CommandLink™ RF host server.
Telnet Server:
The Telnet server allows RF telnet traffic to move back and forth to the terminal. Do not disable the Telnet server if you are using any type of terminal emulation application.
HTTP Server:
Allows firmware updates over the RF link.
113
Page 118
Enable Barcode Daemon:
Allows scanned data to be routed to the keyboard input buffer. Do not disable this function if bar code scanning is required.
Enable User Menu: With "Enable User Menu" set, the M7100 will show a simplified Main Menu while requiring a password to enter an "Administrative Mode". This User Menu gives the end user direct access to the "Reconnect", "Battery Status", "Network Status", "Serial Number", "Host Server Name", and "Contrast". No other tools or settings will be accessible or viewable without entering the password. NOTE: This method of security is much more secure than only enabling password protection on the normal Main Menu, however, if the administrative password is lost, depending on the settings configuration, it may not be possible to retrieve or reset the password in the field.
Keyboard Options The “Keyboard Options” function enables or disables the Key Lock functions.
When the “Enable Func Lock” mode is enabled (checked), the user will be able to “lock” the numeric keypad to select a function when only one key is pressed. This allows quick, single key access to the function keys (when locked into this mode, the numeric keys will require 2 keystrokes). When the “CAPS Lock on Boot” mode is enabled (checked), the M7100 will boot (power on) with the keys set to create CAPITAL characters. The keyboard can be toggled into lower case mode by hitting the [Func] then [Shift] keys.
114
Page 119
Linux Prompt The “Linux Prompt” function puts the M7100 handheld terminal into its native Linux Operating System. Most of the Linux commands are available on the M7100.
115
Page 120
Journaling File System The M7100 Handheld terminal includes the capability to save programs and data. There is a special, non-volatile sub-directory to store user information. This sub-directory is jffs2 (lower case only) and can be accessed from the Linux prompt by typing “cd jffs2”. You can list the contents of this directory by typing “ls” (list).
The jffs2 subdirectory contains all the customer supplied setup files. It is possible to completely reset the terminal back to factory defaults by issuing this command while in the jffs2 subdirectory:
rm –rf * This command will clear all of the user’s settings, do not use this command unless a complete reset is required. You can quickly setup multiple units to have exactly the same settings by copying (FTP’ing) the settings.xxxxxx files to other units. Remember that the RF settings are included in these files and it is possible to get duplicate IP addresses on the network by copying these files. These files also include the WEP settings, which may, or may not, be correct for your network.
FTP You can easily upload and download to the M7100 Handheld terminal over the RF link, by using a File Transfer Program (FTP). These programs are readily available over the Internet. In order to communicate with the M7100, it must be turned on, and you must know its current IP address. Most FTP programs require you to supply a User Name and Password for the connecting device. The default user name is “aml” and the default password is “turk182” (case sensitive).
116