Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 14

M7100 Wireless Handheld Terminal User's Guide, pages 1 to 10

Pages 1 to 10 of 131

The original document is the PDF (4.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the AML M7100

Page 1

M7100 Wireless Handheld Terminal

User’s Guide

© 2007 American Microsystems LTD. Effective Date: May 2007 AML Website: www.amltd.com

Page 2

M7100 HANDHELD TERMINAL

User’s Guide Disclaimer American Microsystems, Ltd. reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult American Microsystems, Ltd. to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of American Microsystems, Ltd. American Microsystems, Ltd. shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of American Microsystems, Ltd.

FCC Declaration of Conformity Product Name: Model 7100 Wireless Handheld Terminal Model Number: M7100 Radio Frequency Interference Requirements

This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This equipment may not cause harmful interference, and (2) this equipment must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If you determine the equipment does cause harmful interference to radio or television reception (this may be determined by monitoring the interference while turning the equipment off and on), you are encouraged to try to correct the interference by one of the following measures: • • • •

Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio or TV technician for help.

Changes or modifications not expressly approved by American Microsystems, Ltd. could void the user's authority to operate the equipment.

Normalización y Certificación Electronica (NYCE) Safety

NOM / NYCE-NOM-019-SCFI-1998 Safety of data processing equipment.

© 2007 American Microsystems, Ltd. All rights reserved. 2190 Regal Parkway • Euless, TX 76040 Phone 817.571.9015 • Fax 817.571.6176 Web Address: www.amltd.com

Page 3

TABLE OF CONTENTS INTRODUCING THE M7100

1

What to Expect

1

Radio Settings (WEP)

33

Warranty

2

Radio Settings (WPA-PSK)

37

General Conventions

2

Radio Settings (WPA-EAP)

38

Simultaneous Hosts Connection

40

M7100 TERMINAL OVERVIEW

3

Multiple Hosts

41

Using the M7100 Keyboard

3

Hosts Log-in Options

42

Key Values

4

Terminal Options

43

The M7100 Display Screen

6

Terminal Emulation - amlterm

43

TheM7100Scanner

6

Terminal Emulation – vt100 / vt220

44

The M7100 Scanner LED

11

Terminal Emulation – tn5250

53

Scanner information and Labeling

12

Power Management

57

The M7100 Internal Radio

14

Diagnostics

59

802.11b Fallback Mode

14

Network Status

59

Interference and Coexistence

14

Resource Information

61

Security Issues

14

Resource Information

62

Ad-Hoc Mode

15

Ping Server

62

GSM/GPRS Network Card Support

17

Print Test Label

64

Installing the GPRS SIM Card

17

Firmware Version

65

Installing the Optional M7100 Handle

21

Serial Number

65

The M7100 Communications Ports

22

Battery Status

65

The M7100 Cradle

23

Barcode Data Viewer

66

Ping USB Server

67

Hardware Tests

67

THE M7100 RF SERVER LOGIN 25 The CommandLink™ Software

25

Network Setup

Local Settings, Laser & CCD Only

32

68

Wait WLAN

25

Barcode Options

68

Connecting

26

Symbology Settings

68

Login

26

Setting the Code 39 Bar Code

69

Applications

27

Setting the UPC Bar Code

70

Telnet

27

Setting the EAN Bar Code

71

Switching Virtual Consoles

27

UPC/EAN Supplements Settings

72

Terminal Emulation

28

Setting the I - 2 of 5 Bar Code

74

Updating Firmware

29

Setting the Codabar Bar Code

75

Setting the Code 128 Bar Code

76

THE M7100 MENU SYSTEM

30

Setting the Code 93 Bar Code

77

Main Menu

30

Setting the MSI/Plessey Bar Code

77

Reconnect

30

Setting the Code 11 Bar Code

79

Contrast

31

Setting the RSS Bar Code

79

Page 4

Decoder Options

81

Setting the Code 32 Bar Code

103

83

Setting the Trioptic Bar Code

104

Barcode Options

83

Decoder Options

104

Symbology Settings

83

Laser / CCD Setting

106

Setting the Code 39 Bar Code

84

Imager Options (2D Imager Only)

107

Setting the PDF417 Bar Code

85

Bar Code Edit Options

108

Setting the MicroPDF417 Bar Code

86

Beep Options

110

Setting the RSS Bar Code

86

Saving Bar Code Settings

110

Setting the Composite Bar Code

87

Date/Time

111

Setting the UPC-A Bar Code

88

Port Configuration

111

Setting the UPC-E Bar Code

89

Startup Options

113

Setting the EAN/JAN-13 Bar Code

90

Keyboard Options

114

Setting the EAN/JAN-8 Bar Code

91

Linux Prompt

115

Setting the 2 of 5(s) Bar Codes

92

Journaling File System

116

Setting the Codabar Bar Code

93

FTP

116

Setting the Code 128 Bar Code

94

Tools/Utilities

117

Setting the Code 93 Bar Code

95

Setting the MSI/Plessey Bar Codes

95

Setting the Code 11 Bar Code

96

Setting the Telepen Bar Code

97

Setting the PosiCode Bar Code

97

THE M7100 EXPANDED MEMORY HANDHELD TERMINAL 119

Setting the Codablock F Bar Code

98

The M7100 Memory Allocation

120

Setting the Code 16K Bar Code

99

File Transfer Protocol (FTP)

121

Setting the Code 49 Bar Code

99

The M7100 Web Server Application

121

Setting the Aztec Bar Code

100

The Links Web Browser Application

121

Setting the QR Code Bar Code

100

Connect 3270 and 5250 TE Clients

124

Setting the Data Matrix Bar Code

101

Stay-Linked 3270 and 5250 TE Clients

124

Setting the MaxiCode Bar Code

101

RFGen Application Development Software125

Setting the Postal Bar Codes

102

The M7100 Tool Chain

Local Settings, 2D Imager Only

Calculator

Force Sleep Now

117

118

125

Page 5

G E T T I N G

S T A R T E D

1

Chapter

Introducing the M7100 This chapter describes how to get started using your M7100 handheld terminal and get you up and running fast.

T he M7100 handheld terminal is an ultra-versatile, high-performance, designed-to-fityour-budget terminal. The ergonomic design easily fits in even the smallest of hands. It is rugged, lightweight, compact and easy-to-use. The high resolution graphical display is capable of presenting a multitude of fonts and images. The M7100 utilizes a true, fully functional, Linux operating system. The Linux operating system is well known for its stability, speed and conservative memory usage. The Linux operating system coupled with the M7100’s high speed processor makes the M7100 one of the fastest handheld terminals on the market today. In test after test the Linux operating system has out-performed DOS based and Windows based operating systems when compared on similar hardware platforms. The M7100 is easy to use and program. Our specifically designed CommandLink™ RF (Radio Frequency) software makes it easy to create custom applications for any requirement. Our terminal emulation software makes it easy to integrate the M7100 into legacy applications as well. You can even utilize standard BASIC software on the M7100 handheld terminal. Power saving features of the M7100 includes auto-off and power save modes, which reduce power consumption until an operator provides input. These features conserve battery power and lengthen the time between charges or battery replacement. The M7100 was designed to operate for a full 8 hour shift without requiring the battery to be recharged or replaced.

What to Expect This user’s guide provides you with an overall physical description, keypad values, technical specifications and performance capabilities of the M7100 handheld terminal. In addition you will learn how to: 1

Page 6

G E T T I N G

S T A R T E D

•

Connect to your host computer

•

Customize your M7100 Terminal

•

Create and execute programs

•

Collect and upload data

•

Send and receive data

•

Connect and use the M7100 serial interface

Warranty A one-year warranty against material defects and workmanship from the date of shipment is guaranteed by American Microsystems, Ltd. Products are sold on the basis of specifications applicable at the time of manufacture. American Microsystems, Ltd. shall have no obligation to modify or update products once sold. At our option, we will repair or replace, at no charge, any unit that proves to be defective providing the appropriate steps are taken to procure an RMA (Return Materials Authorization) number and shipping instructions from American Microsystems, Ltd.

General Conventions Before you begin to use the M7100 terminal, it’s important that you understand key conventions and terms used in this manual. Keys

Description

SMALL CAPS

Refers to a specific menu selection contained in the M7100 in order to continue or complete a task.

[KEY]

The square brackets indicate a specific key on the M7100 handheld terminal’s key pad.

Bold

Words you type – for example when you are instructed to type A:\setup. Bold also refers to existing filenames.

Italic

¤Notes

Italic/Bold

Warning! And section references.

Click/Select

After selecting a procedure or menu, “Click” means to press and release the left mouse button. “Select” means that after you select the menu item or action, you should press ENTER.

2

Page 7

2

Chapter

M7100 Terminal Overview This chapter describes the features of the M7100 terminal.

T o save time in the future, print a copy of this document. Choose Print from the File menu, and press Enter to receive all the pages of examples and instructions.

Using the M7100 Keyboard The M7100 Terminal is equipped with fifty-five keys that are divided into white, grey, blue, red, yellow and black keys. When pressed, each key emits an audible beep to indicate that the M7100 terminal has detected the key press. The red power key turns the M7100 on/off. You must press and hold this key down to power off the unit. This prevents accidentally powering off the unit if this key is momentarily pressed. Note: The Power Key Wake-up feature is only available on units with Decoder version 2.0 or later. On earlier versions the power key will immediately shut off the unit. The Decoder can only be programmed at the factory. The white/black “light bulb” key turns on/off the display backlight. The backlight will automatically shut off after a predetermined time has expired. This predetermined time can be programmed by the user. The yellow [SCAN] button activates the M7100 scan engine. The button is conveniently located for right or left hand use. The seven blue keys consist of [Func], four arrow keys and two [ENTER] keys (for right or left hand use). The [Func] key activates

3

Page 8

the blue Function menu or the blue special characters. Function keys (F1 – F20) can be programmed by many host systems, to be “hot keys” and select specific program items without navigating the entire program. The black [Shift] key toggles between upper and lower case mode and selects special characters on the numeric keypad. There are ten white numeric keys and one white period key. These keys are larger than the less used alpha keys to enable easy inputting of numbers with the right or left thumb. Thirty-three grey keys represent letters, special functions, Space and Menu keys. The [Alt], [Ctl], [Ins], [? ¦ ] (backspace) and [Esc] keys are also grey keys near the bottom of the keyboard.

Key Values Yellow Key SCAN

Activates the built in scan engine. The red LED above the power key indicates when the scan engine is active.

Blue Keys Func

Selects special functions determined by the host system. Hitting Func then a number selects a special function. Functions 1 - 9 are selected by hitting the <Func> then <1> through <9> keys. Functions 11 – 19 are selected by hitting the <Alt> then <1> through <9> keys. Function 10 is selected using the <Func> then <0> key and Function 20 is selected by using the <Alt> then <0> key. Depending on the FUNC LOCK setting, hitting a number key will select a number or a special function. Shift then Func toggles FUNC LOCK on and off.

Enter

Performs the Enter function.

5 (Up arrow)

Moves the display screen up one line at a time or moves the display screen up one menu level. In terminal emulation, the <Shift> then <5> will move the screen up one whole page.

3 (Left arrow)

Moves the cursor left one character at a time and toggles between menu selection options. In terminal emulation, the <Func> then <3> is Back TAB. In terminal emulation, the <Shift> then <3> will move the screen up one whole page.

4

Page 9

6 (Down arrow)

Moves the display screen down one line at a time or moves the display screen down one menu level. In terminal emulation, the <Shift> then <6> will move the screen up one whole page.

4 (Right arrow)

Moves the cursor right one character at a time and toggles between menu selection options. In terminal emulation, the <Func> then <4> is TAB (Forward Tab function). In terminal emulation, the <Shift> then <4> will move the screen up one whole page.

Grey Keys Alpha

Letters A-Z and special characters when Func key is pressed prior to letter key.

Ins

Inserts data at the cursor position and moves all existing data to the right

? ¦

Deletes characters at the cursor position or if cursor follows a string of characters, it deletes the characters to the left of the cursor

Esc

Exits operation being performed

Space

Enters the space character

Red Keys power

Powers unit off/on

Black Key Shift

Selects upper and lower case characters, depending on the CAPS LOCK setting. Func then Shift toggles CAPS LOCK on and off. Shift also selects the special characters on the numeric keypad.

White Keys Numeric

0, 1, 2, 3, 4, 5, 6, 7, 8, 9, . (period) and Backlight Lamp.

To toggle Caps Lock mode on or off, hit [Func] then [Shift]. If Function Lock mode is enabled, to toggle Function Lock mode on or off, hit [Shift] then [Func]. 5

Page 10

The M7100 Display Screen The M7100 handheld terminal includes a 160 pixel by 160 pixel grayscale graphical Liquid Crystal Display (LCD). Programs can be written which mix text and graphics together on the display.

Warning: This display is NOT a touch screen display and the operator should not use sharp objects on the plastic window protecting the LCD display.

The M7100 Scanner The M7100 handheld terminal normally comes equipped with a scan engine that is capable of scanning single dimensional bar codes. An optional Area Imager is available for 2 dimensional bar codes. The M7100 can be ordered with one of the following scan engines installed: Linear Imager Uses LED light and a CCD detector to “image” the bar code. The linear imager has a much shorter scanning distance and is slightly harder to aim. The linear imager is less expensive than the laser scan engines. Scan Rate: 26 Scans / Second Scan Angle: 48º Nominal Min. Print Contrast: Minimum 20% absolute dark/light reflectance measured at 645 nm Standard Range Laser The Standard laser engine uses a moving laser and a standard laser detector. The standard laser is suitable for most applications. The laser is easy to aim and reads most barcodes very quickly. Scan Rate: 35 (± 5) Scans / Second Scan Angle: 42º ± 2º Min. Print Contrast: Minimum 20% absolute dark/light reflectance measured at 650 nm Long Range Laser (LR)

6