Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 3

Model 6000 Wireless Bar Code Decoder, Model 6200 Wireless Host, Model 6300 USB Wireless Host User's Manual, pages 17 to 24

Pages 17 to 24 of 24

The original document is the PDF (187 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the AML M6000 and AML M6300

Page 17

American Microsystems, Ltd. M6000/M6200/M6300 User's Guide 2) SEND MOD 10 CHECK DIGIT ON * Transmit the Mod 10 Check Digit with the bar code entry. OFF

Do not transmit the Mod 10 Check Digit.

CODE 93 0) CODE 93 DECODER ON*

Enable reading Code 93 bar codes.

OFF

Disable reading Code 93 bar codes.

1) CONCATENATE MODE ON Enable Concatenate Mode. The concatenate mode allows the reader to concatenate multiple bar codes in its buffer, and then sends them to the computer just like they were a single bar code. When a Code 93 label with a leading space is read, the reader emits two short beeps and buffers the data without transmission. This process continues until a Code 93 label without a leading space is read or 128 characters are buffered. A Code 93 bar code label that only contains a single or multiple dashes (minus sign) will clear the buffer. OFF*

Disable Concatenate Mode.

MSI/PLESSEY 0) MSI/PLESSEY DECODER ON Enable reading MSI/Plessey bar codes. OFF *

Disable reading MSI/Plessey bar codes.

1) TWO CHECK DIGITS REQUIRED ON Two valid check digits are required for each label. The first check digit is defined by option 2) below. The second check digit is always mod 10. OFF *

One valid check digit is required for each label. The check digit must be mod 10.

2) FIRST CHECK DIGIT MOD 11 ON The First Check Digit must be mod 11. OFF *

The First Check Digit must be mod 10.

3) SEND FIRST CHECK DIGIT ON Transmit the First Check Digit. OFF *

Do not transmit the First Check Digit.

4) SEND SECOND CHECK DIGIT ON Transmit the Second Check Digit. 5) ISBN PLESSEY

OFF *

Do not transmit the Second Check Digit.

ON

Enable reading of Modified Plessey ISBN bar codes. Only eleven digit ISBN bar codes will be read.

OFF*

Do not read Modified Plessey ISBN bar codes.

15

Page 18

American Microsystems, Ltd.

M6000/M6200/M6300 User's Guide

CODE 11 0) CODE 11 DECODER ON

Enable reading Code 11 bar codes.

OFF *

Disable reading Code 11 bar codes.

1) TWO CHECK DIGITS REQUIRED ON Two valid check digits are required for each label. OFF *

One valid check digit is required for each label.

2) SEND FIRST CHECK DIGIT ON Transmit the First Check Digit. OFF *

Do not transmit the First Check Digit.

3) SEND SECOND CHECK DIGIT ON Transmit the Second Check Digit. OFF *

Do not transmit the Second Check Digit.

PREAMBLE

Preamble refers to a user-defined set of characters transmitted at the beginning of each type of bar code data. In addition, a preamble time delay may be set from 0.0 to 9.9 seconds. 0) ENTER PREAMBLE This set of user-defined characters is transmitted at the beginning of bar code data. To define this preamble, scan up to 15 characters from the Full ASCII Chart on the reverse side of the Setup Menu. Scan the “ON” bar code when complete. 1) PREAMBLE SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the bar code preamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 2) ACTIVE TYPES Specifies the types of bar codes that use preambles. Select one of the following: A C E G I K

Code 39 UPC-E EAN-8 Codabar Code 93 Code 11

X* All Bar Codes

B D F H J L

UPC-A EAN-13 Interleaved 2 of 5 Code 128 MSI/Plessey ISBN

POSTAMBLE

Postamble refers to a user-defined set of characters transmitted at the end of each type of bar code data. 0) ENTER POSTAMBLE This set of user-defined characters is transmitted at the end of bar code data. To define this postamble, scan up to 15 characters from the Full ASCII Chart on the reverse side of the Setup Menu. Scan the “ON” bar code when complete. 1) POSTAMBLE SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the bar code postamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds.

16

Page 19

American Microsystems, Ltd.

M6000/M6200/M6300 User's Guide

2) ACTIVE TYPES Specifies the types of bar codes that use postambles. Select one of the following: A C E G I K

Code 39 UPC-E EAN-8 Codabar Code 93 Code 11

X* All Bar Codes

B D F H J L

UPC-A EAN-13 Interleaved 2 of 5 Code 128 MSI/Plessey ISBN

BAR CODE OPTIONS 0) SEND BAR CODE TYPE ID: (ON/OFF) ON:

OFF*:

Sends a letter preceding the data, indicating the symbology type of the bar code. The letter corresponds to the types: A Code 39 B UPC-A C UPC-E D EAN-13 E EAN-8 F Interleaved 2 of 5 G Codabar H Code 128 I Code 93 J MSI/Plessey K Code 11 L ISBN Do not transmit Bar Code Type ID

1) DUPLICATE READS ALLOWED (ON/OFF) ON*:

Enable reading the same bar code multiple times.

OFF:

Disable reading the same bar code twice in a row.

2) BAR CODE FUNCTION KEYS (ON/OFF) ON:

Applies to bar code data, preambles, postambles, and user defined termination characters. Function Keys F1 through F10 will be transmitted in place of the ASCII characters DC1 (11H) through SUB (1AH). The Function Keys values are listed in the Full ASCII Chart on back of the Setup Menu.

OFF*:

Disable Function Keys. (Standard ASCII characters are transmitted.)

3) BAR CODE SPECIAL KEYS This option applies only to bar code data, preambles, postambles, and user defined termination characters. ON*:

Special Key characters will be transmitted in place of a specific set of ASCII characters. The Special Keys are listed in the Full ASCII Chart provided on back of the Setup Menu.

OFF:

Disable Special Keys. (Standard ASCII Characters are transmitted.) Example:

With Special Keys on, the bar code character "STX" will be transmitted as a right arrow, having the affect of pressing the right arrow key on the keyboard.

17

Page 20

American Microsystems, Ltd.

M6000/M6200/M6300 User's Guide

4) BAR CODE TERM CHAR OVERRIDE: (ON/OFF) ON: If any control character or special character (i.e., function key, arrow key, etc.) is embedded in the bar code data, the Termination Character, the Bar Code Preamble, and the Bar Code Postamble will not be transmitted. OFF*:

Special characters do not affect transmission of the Termination Character, the Bar Code Preamble, and the Bar Code Postamble.

5) KEYBOARD AUTO CAPS/NUM LOCK Option is always on for the M6300 USB Wireless Host. For the M6000 and the M6200, with this option on, data is automatically transmitted in the correct upper/lower case, whether the keyboard's settings are turned on or off. ON*: Enable Keyboard Auto Caps/Num Lock. OFF:

Disable Keyboard Auto Caps/Num Lock (data follows keyboard setting) NOTE:

The Keyboard Auto Caps/Num Lock option is not effective on some computers. Indications that this option is not functioning are as follows: Upper/Lower Case is reversed and Special Key characters are not transmitted when Special Keys are on.

6) ALTERNATE NUMERIC KEYS Not used by the M6300 USB Wireless Host. This option is necessary to determine whether you use the numeric keypad or the keyboard for numeric output when scanning a bar code. ON: Send numbers as if entered from the numeric keypad. OFF*:

Sends numbers as if entered from the keyboard.

BAR CODE EDIT

This option allows data editing (modification) before transmission. 0) DATA EDITING Must be on for any of the editing options below to be valid. ON: Enable Data Editing. OFF*: Disable Data Edit ing. 1) ENTER # OF LEADING CHAR TO STRIP (0-9, A-F) Refers to the number (0-15) of characters to be stripped or removed from the beginning of the bar code data. 2) ENTER # OF TRAILING CHAR TO STRIP (0-9, A-F) Refers to the number (0-15) of characters to be stripped or removed from the end of the bar code data. NOTE: If the total number of strip characters (both Leading and Trailing) is greater than the number of characters of the bar code, no characters will be stripped.

18

Page 21

American Microsystems, Ltd.

M6000/M6200/M6300 User's Guide

3) ENTER DATA TYPE TO EDIT Refers to the type of bar codes for which editing can be enabled, allowing editing to be specific to a type of bar code. The choices are listed below: A C E G I K

Code 39 UPC-E EAN-8 Codabar Code 93 Code 11

B D F H J L

UPC-A EAN-13 Interleaved 2 of 5 Code 128 MSI/Plessey ISBN

X* All Bar Codes 4) STRIP LEADING & TRAILING SPACES ON: Any Leading and Trailing Spaces will be stripped from the data. OFF*: No spaces will be stripped.

LASER/CCD OPTIONS

These options are used to configure the laser device behavior and the trigger mode for the M6000 and the M6200/M6300. 0) LASER TRIGGER MODE (0-3) 0) TRIGGER MODE Trigger activates scanning device for one scan only. (Recommended) (M6000/M6200/M6300) 1) PULSE MODE Continuous scanning method for non-reflective backgrounds; for use with MS-941 triggerless scanner only. (M6200/M6300) 2) CONTINUOUS Scans bar codes until the trigger is released or until the laser/CCD time-out is reached. (M6200/M6300) 3) BLINK MODE Continuous scanning with no time-out. Laser/CCD turns on and off allowing safe operation. (M6200/M6300) NOTE: Continuous or Blink mode options not available on the M6000. When enabled on the M6200, wireless communications are disabled. 1) LASER/CCD TIMEOUT: Turns off Laser/CCD after (0 – 9) seconds. 2) READ DELAY: Allows re-reads. Continuous run read delay (0.0 – 9.9) seconds is used to allow a new re-read of a bar code, after the read delay expires. 3) READ VERIFICATION: Performs re-reads the number of times (0 – 9) required for accuracy critical applications.

TERMINATION CHARACTER

The optional Termination Character is transmitted at the end of the data. If a user defined Termination Character is desired, select option 4) below, then scan a single character from the Full ASCII section of the Setup Menu. Note that there are differences between a USB keyboard (M6300) and a traditional keyboard (M6200). 0 None 1 Horizontal Tab (M6200 & M6000: ASCII 09 M6300: Tab Key) 2 * Carriage Return (M6200 & M6000: ASCII 13 M6300: Enter Key) 3 Carriage Return & Line Feed (M6200 & M6000: ASCII 13 & ASCII 10 M6300: not used) 4 User Defined Termination Character

19

Page 22

American Microsystems, Ltd.

M6000/M6200/M6300 User's Guide

HOST KEYBOARD TYPE

The Keyboard Type for the M6200 must be set properly for the data to transmit correctly. The Universal keyboard type can be used for all international keyboards. Choose from the following types: 0 *USA (English) 1 French 2 German 3 Italian 4 Universal

HOST TRANSMIT SPEED

The Transmit Speed option for the M6200/M6300 sets the speed at which data is transmitted to the computer. Some computer systems may require the transmission speed set to a slower speed. The default setting is Fast (3). Choose from the following: 0 Slow 1 Medium slow 2 Medium fast 3 *Fast

SCAN BEEP

Settings (0-3) set the length of the beep. Settings (4-7) set the tone (pitch) of the beep. Setting (8), when selected will override the other beep selections and shut the beep off. Length 0 Short 1 * Medium Short 2 Medium Long 3 Long Tone 4 Low 5 Medium Low 6 * Medium High 7 High Off 8 No Beep NOTE:

In order for the unit to beep only when data has been received and acknowledged by the host, turn this option (8 off.

PORTABLE ACKNOWLEDGE BEEP

Settings (0-2) set the length of the beep for the M6000. Settings (3-5) set the tone (pitch) of the beep. Setting (6) Number of Beeps, selects the number of beeps sent. Length 0 *Short 1 Medium Short 2 Long

20

Page 23

American Microsystems, Ltd.

M6000/M6200/M6300 User's Guide

Tone 3 Low 4 Medium 5 *High Number of Beeps 6 Number of Beeps (0-2*)

DIAGNOSTICS

This option executes a self-test program that performs the following tests on the M6000 and the M6200/M6300:

• Firmware Version Number • Report Host ID # Setting and Portable ID # Setting • Internal Ram Test • EPROM Checksum Test • Character Set Test • Beeper Test The above tests are performed and their status is displayed on the PC. A Wireless Host connected to a PC is required to see the text of the diagnostic status report. If the text is not displayed on the PC window, the Wireless Host is not configured properly. See Setting the Host ID and Setting the Portable ID in this manual. If there are problems related to the test results, please contact American Microsystems' technical support at (800) 648-4452 during the hours 8:30 A.M. to 5:30 P.M. Monday through Thursday and 8:30 A.M. to 5:00 P.M Friday.

PORTABLE SHUTDOWN TIME

This option is used to conserve battery life, and allows the M6000 to be used efficiently with wand devices. The M6000 has an on button, used to turn-on the M6000. There is no off position on the button. Instead, if the M6000 is sitting idle too long, the M6000 will shut-off power automatically. Scanning data or other activity will reset the countdown time, as the M6000 is not sitting idle. This time may be set from 01 to 99 minutes. Note that a 00 setting will set the M6000 for constant run with no power off. The default setting is ten (10) minutes. Example: Scan the “0” for the “tens” digit and the “1” for the “ones” digit. This selects the time “01”, or 1 minute.

21

Page 24

American Microsystems, Ltd.

M6000/M6200/M6300 User's Guide

SIGNAL DEFINITIONS

The following wiring diagram is provided to assist in the construction and/or repair input/output device cables:

LASER/CCD/WAND INTERFACE

Pin 1 2 3 4 5 6 7 8 9

Signal Sync Data Decode LED No Connection Trigger Head Enable Ground Shield Ground Laser/CCD/Wand power

Pin 1 2 3 4 5 6 7 8 9

Signal PC Port Clock No Connection No Connection PC Port Data Ground Keyboard Clock No Connection Keyboard Data +5 volt Power

DB9 Male Connector

M6200 KEYBOARD INTERFACE

DB9 Female Connector

22