The text of a manual · part 2 of 3
Model 6000 Wireless Bar Code Decoder, Model 6200 Wireless Host, Model 6300 USB Wireless Host User's Manual, pages 9 to 16
Pages 9 to 16 of 24
The original document is the PDF (187 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Page 9
American Microsystems, Ltd. M6000/M6200/M6300 User's Guide Step 4: Set the Portable ID by scanning PORTABLE ID ADDRESS and then select the number (0 to 9) to identify each M6000, at the right side of the Setup Menu. Step 5: Step 6:
Step 7:
If you wish to keep and store these changes, scan EXIT (SAVE CHANGES). If you wish to discard these changes, and revert to your previous settings, select EXIT (IGNORE CHANGES). Open a text editor, such as Microsoft Notepad on your PC. Scan the START bar code from the Setup Menu again. Then scan DIAGNOSTICS. Scan the EXIT (IGNORE CHANGES) bar code. Note that the current Host ID and the Portable ID settings are displayed along with other M6000 diagnostic information in the PC window. If the M6000 diagnostic data from Step 7 was displayed on the PC, the system is configured correctly; however, if no data is displayed, make sure the Wireless Host unit is connected and that the Host ID setting is correct and unique. Verify the Host ID setting by connecting a scanning device to the Wireless Host and scanning START, DIAGNOSTICS, and EXIT (IGNORE CHANGES).
DEFAULT SETTINGS
The M6000 and the M6200/M6300 default settings can be restored, aborting all user changes, using the Model 6000/6200/6300 Setup Menu by scanning START, RESET ALL DEFAULTS, and EXIT (SAVE CHANGES). Using the Setup Menu, the individual settings of the M6000 and the M6200/M6300 can be changed by the user, see Changing the Default Settings. The M6000 and the M6200/M6300 are shipped from the factory with the following default settings:
Code 39
Code 39 Decoder Full ASCII Mod 43 Check Digit Send Check Digit Concatenate Mode
ON OFF OFF OFF OFF
EAN EAN Decoder Zero Fill EAN-8 to EAN-13 Send EAN-13 Country Code Send EAN-8 Country Code Send EAN-13 Check Digit Send EAN-8 Check Digit ISBN Conversion
INTERLEAVED 2 of 5 I 2 of 5 Decoder Check Digit Send Check Digit Fixed Length Set Fixed Length #1 Set Fixed Length #2
ON OFF ON ON ON ON OFF ON None OFF OFF 02 06
UPC
UPC Decoder Convert UPC-E to UPC-A Convert UPC-A to EAN-13 Send UPC-A Number System Send UPC-E Number System Send UPC-A Check Digit Send UPC-E Check Digit
UPC/EAN SUPPLEMENTS Supplements Decoder Allow 2 Digit Supplements Allow 5 Digit Supplements Require Supplements Send Separator Space
CODABAR
Codabar Decoder Send Start/Stop CLSI Formatting CLSI Check Digit
7
ON OFF OFF ON ON ON ON OFF ON ON OFF OFF
ON OFF OFF OFF
Page 10
American Microsystems, Ltd.
CODE 128
Code 128 Decoder UCC-128 Verification Send Mod 10 Check Digit
MSI/PLESSEY
MSI/Plessey Decoder Two Check Digits Required First Check Digit Mod 11 Send 1st Check Digit Send 2nd Check Digit ISBN Plessey
PREAMBLE
Enter Preamble Preamble Send Delay Active Types
M6000/M6200/M6300 User's Guide
ON OFF ON OFF OFF OFF OFF OFF OFF OFF 0.0 sec ALL
BAR CODE OPTIONS
Send Bar Code Type ID OFF Duplicate Reads Allowed ON Bar Code Function Keys OFF Bar Code Special Keys ON Bar Code Term Char Override OFF Keyboard Auto Caps/ Num Lock ON Alternate Numeric Keys OFF
LASER/CCD OPTIONS Laser Trigger Mode Laser/CCD Timeout Read Delay Read Verification
CODE 93
Code 93 Decoder Concatenate Mode
ON OFF
CODE 11
Code 11 Decoder Two Check Digits Required Send 1st Check Digit Send 2nd Check Digit
OFF OFF OFF OFF
POSTAMBLE
Enter Preamble Postamble Send Delay Active Types
OFF 0.0 sec ALL
BAR CODE EDIT
Bar Code Editing Enter # of Leading Chars to Strip Enter # of Trailing Chars to Strip Enter Bar Code Type to Edit Strip Leading&Trailing Spaces
OFF 0 0 ALL OFF
TERMINATION CHARACTER
0 2) Carriage Return (USB, Enter Key) 3 sec 0.0 sec HOST TRANSMIT SPEED 0 3) Fast
HOST KEYBOARD TYPE
PORTABLE ID ADDRESS
HOST ID ADDRESS
PORTABLE SHUTDOWN TIME
0) USA (English) Host Unit ID
SCAN BEEP
Length: 1) Medium Short Tone: 6) Medium High
Portable Unit 1
1
10 minutes
PORTABLE ACKNOWLEDGE BEEP 0) Short 5) High 6) Number of beeps: 2
8
Page 11
American Microsystems, Ltd.
M6000/M6200/M6300 User's Guide
CHANGING THE DEFAULT SETTINGS
You can easily change the settings by simply scanning the bar code options located on the M6000/M6200/M6300 Setup Menu. The Setup Menu is a sheet of bar codes supplied with this manual and will be available for download from the American Microsystems’ website: www.barcodepower.com. The basic programming sequence is similar to the process used in Setting the Host ID and follows the form: START ..CATEGORY …OPTION (0 to 9) ….ON/OFF or NUMBER DATA …..EXIT (SAVE CHANGES) or EXIT (IGNORE CHANGES) Follow these instructions to change any setting: Step 1:
Scan the START bar code at the top left corner of the M6000/M6200/M6300 Setup Menu. This puts the M6000 and the M6200/M6300 into the program mode.
Step 2:
Scan one of the Category labels (i.e. Code 39, UPC, and Beep)
Step 3:
Select the desired numbered option by scanning one of the numeric labels (0 – 9). If an invalid choice is made the M6000 and the M6200/M6300 will emit an error beep. If there is only one option under the label, go to Step 4.
Step 4:
If there is a (ON/OFF) next to the description, scan ON to enable or OFF to disable the option. Example: To disable the UPC-A Check Digit perform the following: 1) Scan the UPC category label. 2) Scan the option 5) label to select the Send UPC-A Check Digit option. 3) Scan the OFF label to disable the option. If there is a range of numbers next to the option, scan numeric labels located on the right side of the Setup Menu Sheet. Some options require only one (1) digit, these appear as (0-9). Others require two digits, for example (0.0-9.9), and both digits must be entered. Example: To set the Preamble Send Delay to one (1.0) second, perform the following: 1) Scan the PREAMBLE category label. 2) Scan the (1) digit for Preamble Send Delay. 3) Scan 1 for the one digit and scan 0 for the tenths digit. This selects the time 1.0, or 1 second. NOTE: The default setting is 0.0 seconds.
Step 5:
If you want to make another change within the same Category, you can scan another option number (i.e. return to Step 3 above). If you want to change an option in a different Category, you must first scan the new category (i.e. return to Step 2 above and repeat the steps).
Step 6:
When you have finished making all the changes, you can either:
9
Page 12
American Microsystems, Ltd.
M6000/M6200/M6300 User's Guide
1)
Scan the EXIT (SAVE CHANGES) label on the Setup Menu to save all the changes and then exit the menu to return to normal bar code reader operation.
2)
Scan the EXIT (IGNORE CHANGES) label on the Setup Menu to discard, without saving, all the changes and then exit the menu to return to normal bar code reader operation.
PROGRAMMING GUIDE START
The START bar code places the reader into the program mode. After scanning this label, the reader will emit three short beeps to indicate that it is in the program mode.
EXIT (SAVE CHANGES) Scan this bar code to exit the program mode and save all of the changes. After scanning this label, the reader will beep twice then delay approximately one second and emit three short beeps to indicate that it accepted the changes. EXIT (IGNORE CHANGES) Scan this bar code to exit the program mode and discard all of the current changes. The reader will use the settings that were in effect before entering the program mode. RESET ALL DEFAULTS Scan this bar code to reset all options to their default settings. NOTE: Defaults are marked with “*”. 0-9 BAR CODES These bar codes are scanned to select various options and enter programmable data into the reader.
ON OFF
NOTE: Scan option 9) to reset all of the options within the current Category back to default. If the option has an (ON/OFF) beside the description, scan the ON bar code to turn on the current option.
If the option has an (ON/OFF) beside the description, scan the OFF bar code to turn off the current option. FULL ASCII CHART The Full ASCII Chart is located on the back of the Setup Menu. This chart contains the entire ASCII character set (128 characters). Use this chart to enter Preamble and Postamble character strings as well as the Termination Character and Bar Code Type to Edit options. ADDITIONAL NOTES: If the description beside the option contains: (ON/OFF) Then scan either an ON or OFF label to set the option. (CHART) Then scan one or more characters from the Full ASCII Chart. (0-9) Scan the desired character from the 0-9 labels. (00-99) Scan two desired characters from the 0-9 labels. (0.0-9.9) Scan two characters from the 0-9 labels to set the time from 0.0 to 9.9 seconds.
10
Page 13
American Microsystems, Ltd.
M6000/M6200/M6300 User's Guide
CODE 39 0) CODE 39 DECODER ON*
Enable reading Code 39 bar codes.
OFF
Disable reading Code 39 bar codes.
ON
Enable the Full ASCII Extension to Code 39. Option 0) above must be set on.
OFF*
Disable the Full ASCII Extension to Code 39. This sets the reader to the standard Code 39 mode.
1) FULL ASCII
2) MOD 43 CHECK DIGIT ON Enable the Mod 43 Check Digit for Code 39. When this option is enabled, only Code 39 labels that contain a valid check digit will be read. OFF* 3) SEND CHECK DIGIT ON OFF*
Disable the Mod 43 Check Digit. Check digit verification will not be performed. Transmit the Mod 43 Check Digit with the bar code data. Requires option 2) above to be set on. Do not transmit the Mod 43 Check Digit.
4) CONCATENATE MODE ON Enable Concatenate Mode. The concatenate mode allows the reader to accumulate multiple bar codes in its buffer, then sends them to the computer just like they were a single bar code. When a Code 39 label containing a leading space is read, the reader emits two short beeps and buffers the data without transmission. This process continues until a Code 39 label without a leading space is read or 128 characters are buffered. A Code 39 bar code label that only contains a single or multiple dashes (minus sign) will clear the buffer. OFF*
Disable Concatenate Mode.
UPC 0) UPC DECODER ON*
Enable reading UPC-A and UPC-E bar codes.
OFF
Disable reading UPC-A and UPC-E bar codes.
1) CONVERT UPC-E TO UPC-A ON Convert all UPC-E labels to their UPC-A equivalents before transmission. After conversion, the reader will follow the UPC-A programming options. OFF*
No conversions will be performed.
11
Page 14
American Microsystems, Ltd.
M6000/M6200/M6300 User's Guide
2) CONVERT UPC-A TO EAN-13 ON Convert all UPC-A labels to an equivalent EAN-13 format by inserting a leading zero. After conversion, the reader will follow the EAN-13 programming options. OFF*
No conversions will be performed.
3) SEND UPC-A NUMBER SYSTEM ON* Transmit the UPC-A Number System character. OFF
Do not transmit the UPC-A Number System character.
4) SEND UPC-E NUMBER SYSTEM ON* Transmit the UPC-E Number System character. OFF
Do not transmit the UPC-E Number System character.
5) SEND UPC-A CHECK DIGIT ON* Transmit the UPC-A Check Digit character. OFF
Do not transmit the UPC-A Check Digit character.
6) SEND UPC-E CHECK DIGIT ON* Transmit the UPC-E Check Digit character. OFF
Do not transmit the UPC-E Check Digit character.
EAN 0) EAN DECODER ON*
Enable reading EAN-8 and EAN-13 bar codes.
OFF
Disable reading EAN-8 and EAN-13 bar codes.
1) ZERO FILL EAN-8 TO EAN-13 ON* Add five leading zeros to EAN-8 labels. After conversion, the reader will follow the EAN-13 programming options. OFF
No conversions will be performed.
2) SEND EAN-13 COUNTRY CODE ON* Transmit the EAN-13 Country Code. OFF
Do not transmit the EAN-13 Country Code.
3) SEND EAN-8 COUNTRY CODE ON* Transmit the EAN-8 Country Code. OFF
Do not transmit the EAN-8 Country Code.
4) SEND EAN-13 CHECK DIGIT ON* Transmit the EAN-13 Check Digit character. OFF
Do not transmit the EAN-13 Check Digit character.
5) SEND EAN-8 CHECK DIGIT ON* Transmit the EAN-8 Check Digit character. OFF 6) ISBN CONVERSION ON OFF*
Do not transmit the EAN-8 Check Digit character. Convert 13 DIGIT BOOKLAND/EAN (978) prefix to its corresponding 10-digit ISBN number. Do not convert Bookland/EAN to an ISBN number.
12
Page 15
American Microsystems, Ltd.
M6000/M6200/M6300 User's Guide
UPC/EAN SUPPLEMENTS 0) SUPPLEMENTS DECODER ON Enable reading UPC, EAN & Bookland supplements. OFF* Disable reading UPC, EAN & Bookland supplements. 1) ALLOW 2 DIGIT ON* OFF 2) ALLOW 5 DIGIT ON* OFF 3) REQUIRE UPC SUPPLEMENTS
ON* OFF
4) REQUIRE EAN SUPPLEMENTS
ON* OFF
5) REQUIRE BOOKLAND SUPPLEMENTS ON* OFF
Enable reading 2 digit supplements. Option 0) above must be set on. Disable reading 2 digit supplements. Enable reading 5 digit supplements. Option 0) above must be set on. Disable reading 5 digit supplements.
Enable reading UPC supplements. Option 0) above must be set on. Disable reading UPC supplements.
Enable reading EAN supplements. Option 0) above must be set on. Disable reading EAN supplements.
Enable reading Bookland supplements. Option 0) above must be set on. Disable reading Bookland supplements.
6) SEND SEPARATOR SPACE ON Inserts a space between the standard bar code data and the supplemental data. OFF* No separator space is inserted.
INTERLEAVED 2 OF 5 0) I 2 OF 5 DECODER ON* OFF
Enable reading Interleaved 2 of 5 bar codes. Disable reading Interleaved 2 of 5 bar codes.
1) CHECK DIGIT: 0=NONE, 1=USS, 2=OPCC Specifies which check digit type will be used with Interleaved 2 of 5: 0* = None (no check digit required) 1 = Uniform Symbology Specification (3-1-3 mod 10) 2 = Optical Product Code Council (2-1-2 mod 10) 2) SEND CHECK DIGIT ON OFF*
Transmit the Interleaved 2 of 5 check digit with the bar code data. The check digit is not transmitted.
13
Page 16
American Microsystems, Ltd. 3) FIXED LENGTH
M6000/M6200/M6300 User's Guide
ON
Read only Fixed Length Interleaved 2 of 5 bar code labels that match the lengths defined in options 4) & 5) below. The check digit can be on or off.
OFF*
Disable Fixed Length mode. Read all Interleaved 2 of 5 labels without regard to length.
4) SET FIXED LENGTH #1 (02-60) Sets the first valid Fixed Length for Interleaved 2 of 5. Scan a two-digit value to enter the length. Valid lengths are 02 to 60 characters. By definition, the lengths of Interleaved 2 of 5 labels are an even number of characters. The default Fixed Length is 2 characters. 5) SET FIXED LENGTH #2 (02-60) Sets a second valid Fixed Length for Interleaved 2 of 5. Scan a twodigit value to enter the length. The default length is set to 6 characters.
CODABAR 0) CODABAR DECODER ON * OFF 1) SEND START/STOP ON OFF * 2) CLSI FORMATTING ON
OFF * 3) CLSI CHECK DIGIT ON
OFF*
Enable reading Codabar bar codes. Disable reading Codabar bar codes. Transmit the Codabar start/stop characters. Do not transmit the Codabar start/stop characters. The reader will insert a blank after the 1st, 5th, and 10th characters of a 14-character Codabar label. The label length does not include the start and stop characters. Disable CLSI formatting. Enable the CLSI check digit. When this option is enabled, all fourteen digit numeric bar codes must contain a valid check digit. Disable the CLSI check digit. Check digit verification will not be performed.
CODE 128 0) CODE 128 DECODER ON * OFF
Enable reading Code 128 bar codes. Disable reading Code 128 bar codes.
1) UCC-128 VERIFICATION ON A valid Mod 10 Check Digit is required on UCC-MOD 10 bar codes. (Applies to 20-digit serial shipping container bar codes.) OFF *
UCC-MOD 10 bar codes are accepted without valid Mod 10 Check Digits.
14