The text of a manual · part 4 of 7
M5900 Portable Data Terminal User's Guide, pages 31 to 40
Pages 31 to 40 of 64
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the AML M5900
Page 31
Allows the user to override a Termination Character embedded in a bar code. If the bar code has a non-printable termination character, it will be truncated and replaced by the selected termination character.
Scanner Settings
These options are used to configure the laser or CCD device behavior, and the trigger mode for the M7100 handheld terminal.
TRIGGER
PULSE
Trigger Mode Trigger activates scanning device for as long as trigger is held up to the Laser Timeout value in seconds. (Recommended) Pulse Mode Continues to keep the scanner active even when the trigger is not held down, up to the Laser Timeout value in seconds. <--> Scan Timeout
24
Page 32
Turns off Laser / CCD after (1 – 9) seconds when the trigger is pushed in Pulse mode, or held down in Trigger mode. The laser / CCD will always turn off immediately after a good read. <--> Read Verify Performs bar code re-reads the number of times (0 – 9) required for applications where accuracy is critical. This is used where the bar code is poorly printed or damaged.
Symbologies
The “Symbology Settings” function allows you to make changes to each individual bar code. CODE 39
Full ASCII ON
Enable the Full ASCII Extension to Code 39. This allows the scanner to read upper and lower case characters as well as extended special characters.
OFF* Disable the Full ASCII Extension to Code 39. This sets the reader to the standard Code 39 mode. Mod 43 Chk Digit 25
Page 33
ON
Enable the Mod 43 Check Digit for Code 39. When this option is enabled, only Code 39 labels that contain a valid check digit will be read.
OFF* Disable the Mod 43 Check Digit. Check digit verification will not be performed. Send Chk Digit ON
Transmit the Mod 43 Check Digit with the bar code data. Requires the “Mod 43 Check Digit” option above to be set on.
OFF* Do not transmit the Mod 43 Check Digit. Concatenate Mode ON
Enable Concatenate Mode. The concatenate mode allows the M7100 handheld terminal to accumulate multiple bar codes in its buffer and then sends them to the computer just like they were a single bar code. When a Code 39 label containing a leading space is read, the M7100 emits two short beeps and buffers the data without transmission. This process continues until a Code 39 label without a leading space is read or 128 characters are buffered. A Code 39 bar code label that only contains a single or multiple dashes (minus sign) will clear the buffer.
OFF* Disable Concatenate Mode. UPC
UPC-E:
Convert to UPC-A ON
Convert all UPC-E labels to their UPC-A equivalents before transmission. After conversion, the reader will follow the UPC-A programming options.
OFF* No conversions will be performed. Send System ON*
Transmit the UPC-E Number System character. 26
Page 34
OFF
Do not transmit the UPC-E Number System character. Send Check Digit
ON*
Transmit the UPC-E Check Digit character.
OFF
Do not transmit the UPC-E Check Digit character.
UPC-A:
Convert to EAN-13 ON
Convert all UPC-A labels to an equivalent EAN-13 format by inserting a leading zero. After conversion, the reader will follow the EAN-13 programming options.
OFF* No conversions will be performed. Send System ON*
Transmit the UPC-A Number System character.
OFF
Do not transmit the UPC-A Number System character. Send Check Digit
ON* Transmit the UPC-E Check Digit character. OFF
Do not transmit the UPC-E Check Digit character.
EAN
0-Fill EAN8 to EAN13 ON*
Add five leading zeros to EAN-8 labels. After conversion, the reader will follow the EAN-13 programming options.
OFF
No conversions will be performed.
27
Page 35
ISBN Conversion ON
Convert 13 DIGIT BOOKLAND/EAN (978) prefix to its corresponding 10-digit ISBN number.
OFF* Do not convert Bookland/EAN to an ISBN number. EAN-8: Send Country Code ON*
Transmit the EAN-8 Country Code.
OFF
Do not transmit the EAN-8 Country Code. Send Check Digit
ON*
Transmit the EAN-8 Check Digit character.
OFF
Do not transmit the EAN-8 Check Digit character. EAN-13 Send Country Code
ON*
Transmit the EAN-13 Check Digit character.
OFF
Do not transmit the EAN-13 Check Digit character.
Send Check Digit ON*
Transmit the EAN-13 Check Digit character.
OFF
Do not transmit the EAN-13 Check Digit character.
SUPPLEMENTS
Allow 2 Digit Sup 28
Page 36
ON*
Enable reading 2 digit supplements. Option 0) above must be set on.
OFF
Disable reading 2 digit supplements. Allow 5 Digit Sup
ON*
Enable reading 5 digit supplements. Option 0) above must be set on.
OFF
Disable reading 5 digit supplements. Require UPC Sup
ON*
Enable reading UPC supplements. Option 0) above must be set on.
OFF
Disable reading UPC supplements. Require EAN Sup
ON*
Enable reading EAN supplements. Option 0) above must be set on.
OFF
Disable reading EAN supplements. Require Bookland Sup
ON*
Enable reading Bookland supplements. Option 0) above must be set on.
OFF
Disable reading Bookland supplements. Send Separator Space
ON
Inserts a space between the bar code data and the supplemental data.
OFF* No separator space is inserted.
INT 2 OF 5
USS Check Digit Specifies if the USS check digit type will be used with Interleaved 2 of 5: 29
Page 37
ON
Uniform Symbology Specification (3-1-3 mod 10)
OFF* None (no check digit required) OPCC Check Digit Specifies if the OPCC check digit type will be used with Interleaved 2 of 5: ON
Optical Product Code Council (2-1-2 mod 10)
OFF* None (no check digit required) Send Check Digit ON
Transmit the Interleaved 2 of 5 check digit with the bar code data.
OFF* The check digit is not transmitted. Enable Fixed Length ON
Read only Fixed Length Interleaved 2 of 5 bar code labels that match the lengths defined in “Set Fixed Length #1 - #3” options below. The check digit can be on or off.
OFF* Disable Fixed Length mode. Read all Interleaved 2 of 5 labels without regard to length.
<--> 1 Sets the first valid Fixed Length for Interleaved 2 of 5. Enter a two-digit value to enter the length. Valid lengths are 02 to 60 characters. By definition, the lengths of Interleaved 2 of 5 labels are an even number of characters. The default Fixed Length is 2 characters. <--> 2 Sets a second valid Fixed Length for Interleaved 2 of 5. Enter a two-digit value to enter the length. The default length is set to 6 characters. <--> 3 Sets a third valid Fixed Length for Interleaved 2 of 5. Enter a two-digit value to enter the length. The default length is set to 6 characters.
30
Page 38
CODABAR
Send Start / Stop ON
Transmit the Codabar start/stop characters.
OFF * Do not transmit the Codabar start/stop characters. CLSI Formatting ON
The reader will insert a blank after the 1st, 5th, and 10th characters of a 14-character Codabar label. The label length does not include the start and stop characters.
OFF * Disable CLSI formatting. CLSI Check Digit ON
Enable the CLSI check digit. When this option is enabled, all fourteen digit numeric bar codes must contain a valid check digit.
OFF* Disable the CLSI check digit. Check digit verification will not be performed.
CODE 128
31
Page 39
UCC-128 Verification ON
A valid Mod 10 Check Digit is required on UCC-MOD 10 bar codes. (Applies to 20-digit serial shipping container bar codes.)
OFF * UCC-MOD 10 bar codes are accepted without valid Mod 10 Check Digits. Send Mod 10 Chk Digi ON * Transmit the Mod 10 Check Digit with the bar code entry. OFF
Do not transmit the Mod 10 Check Digit. Send EAN Type ID
ON * Transmit the EAN Type ID. OFF
Do not transmit the EAN Type ID.
CODE 93
Concatenate Mode ON
Enable Concatenate Mode. The concatenate mode allows the reader to concatenate multiple bar codes in its buffer, and then sends them to the computer just like they were a single bar code. When a Code 93 label with a leading space is read, the reader emits two short beeps and buffers the data without transmission. This process continues until a Code 93 label without a leading space is read or 128 characters are buffered. A Code 93 bar code label that only contains a single or multiple dashes (minus sign) will clear the buffer.
OFF* Disable Concatenate Mode.
32
Page 40
MSI / PLESSY
2 Chk Digits Required ON
Two valid check digits are required for each label. The first check digit is defined by option 2) below. The second check digit is always mod 10.
OFF * One valid check digit is required for each label. The check digit must be mod 10. 1st Chk Digit Mod 11 ON
The First Check Digit must be mod 11.
OFF * The First Check Digit must be mod 10. Send 1st Check Digit ON
Transmit the First Check Digit.
OFF * Do not transmit the First Check Digit. Send 2nd Check Digit ON
Transmit the Second Check Digit.
OFF * Do not transmit the Second Check Digit. ISBN Plessey ON
Enable reading of Modified Plessey ISBN bar codes. Only eleven digit ISBN bar codes will be read.
OFF* Do not read Modified Plessey ISBN bar codes.
33