Page 129

12Maintenance Introduction With proper care the M3000 should provide years of trouble-free operation. The following provides general information on the care and upkeep of the unit.

Battery Replacement Depending on operating conditions, the 9V Alkaline battery should provide from 10 to 70 hours of operation. When the battery power drops below an acceptable level the M3000 prompts:

Battery Low Press Any Key To replace the battery: 1.

Place the M3000 face down as shown in the following illustration.

2.

Press down on the battery compartment cover, and slide the cover away from the case of the M3000.

3.

Carefully lift the battery from the case.

4.

Un-snap the old battery and replace with a new, 9-Volt Alkaline battery.

5.

Replace the battery cover.

12-1

Page 130

M3000 Portable Bar Code Reader User's Guide

EPROM Replacement 1.

Disconnect any cables, scanning devices and power supplies from the M3000 portable.

2.

Turn on the M3000. Press the EXIT key until the display shows:

Portable Mode Select Function and then shut the M3000 off. NOTE: This is a very important step and will prevent loss of any data or programs 3.

Turn the M3000 upside down and remove the four screws from the bottom of the case. Return the M3000 back to the upright position.

4.

Lift the top half of the M3000 case straight up until the four plastic posts have cleared the circuit board. Next, fold the top of the case back until the keyboard is facing downward. NOTE: Do not disconnect the keyboard.

5.

Carefully lift the circuit board up out of the M3000 lower case and fold it over on the top part of the case that you removed earlier. NOTE: The battery wires still connect the circuit board to the lower case - do not disconnect the battery wires.

6.

Locate the EPROM chip that has the white label on top. Using a small slot head screwdriver - carefully pry the chip from the socket.

Dimple on This End of EPROM

M3000 EPROM Alignment 7.

Take the new version EPROM chip and insert it into the socket with the dimple in the end of the chip facing the outer edge of the circuit board. If the pins of the chip do not line up with the socket, you may need to bend the chip's pins slightly to align them with the the socket. Press the EPROM chip firmly into place. NOTE: Sometimes if the pins are not aligned correctly, the pins will bend out or in, and will not make proper contact with the socket.

12-2

8.

Verify that all EPROM pins are inserted into the socket

9.

Carefully re-assemble the M3000 portable unit making sure that the battery cables do not get pinched between the circuit board and the battery compartment.

Page 131

12Maintenance

Avoiding Damage The M3000 can be damaged by any of the following conditions:

Electrical The electronic components of the M3000 can be damaged by exposure to intense electrical fields. If possible, avoid exposing the unit to the following conditions: •

Electrostatic discharge produced by friction. For example, heavily carpeted areas during periods of low humidity.

•

Avoid using the M3000 with a Modem during electrical storms.

•

Avoid exposure to any source of intense arcing.

•

Exposure to powerful electromagnetic fields. For example, large motors, induction coils, transformers, etc.

•

Exposure to sources of ionizing radiation. For example, x-rays, etc.

Mechanical Avoid the following: •

Direct exposure to water. Do not immerse.

•

Severe drops or physical impact.

•

Extreme heat or open flame. For example, do not leave on the dash board or inclosed in a vehicle.

•

Highly corrosive environments

•

Strong industrial cleaning solvents

Cleaning When the unit needs cleaning, use only a soft cloth, dampened in clean warm water. Do not use petroleum based solvents, or powerful detergents.

.

12-3

Page 132

Appendixes

A-1

Page 133

M3000 Portable Bar Code Reader User's Guide

APPENDIX A - BAR CODE FUNCTION & SPECIAL KEYS With FUNCTION KEYS enabled, the decoder can accept a given ASCII character and transmit a corresponding FUNCTION KEY to the computer. The ASCII characters and values are listed in the table below.

FUNCTION KEYS ASCII CHARACTERS DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB

FUNCTION KEYS F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

ASCII VALUES 17 18 19 20 21 22 23 24 25 26

SPECIAL KEYS With SPECIAL KEYS enabled, the decoder can accept a given ASCII character and transmit a corresponding SPECIAL KEY to the computer. The ASCII characters and values are listed in the table below.

ASCII CHARACTERS SOH STX ETX EOT

A-2

SPECIAL KEYS

← (Left Arrow) → (Right Arrow) ↑ (Up Arrow) ↓ (Down Arrow)

ASCII VALUES 1 2 3 4

ENQ

HOME

5

ACK

END

6

BEL

DELETE

7

VT

PAGE UP

11

FF

PAGE DOWN

12

SO

SHIFT ON

14

SI

SHIFT OFF

15

DLE

INS

16

FS

CTRL ON

28

GS

CTRL OFF

29

RS

ALT ON

30

US

ALT OFF

31

Page 134

Appendixes

APPENDIX B - CODE 39 SPECIFICATIONS Code 39 is a variable length alphanumeric code. Each character is made up of nine elements, five bars and four spaces. Three of the elements are wide and six are narrow. Code 39 is a popular choice for applications because: • • • it is easy to print with low cost dot matrix printers large character set (A-Z, 0-9, 7 special characters) code can be extended to include the entire 128 ASCII character set variable length

CHARACTERISTICS: Character Set:

26 uppercase letters (A - Z) 10 digits (0 - 9) 7 special characters (SPACE -.$/+%) Symbol Length: Variable Check Digit: Optional Bi-directional Decoding: Yes Maximum Density: 9.8 char./inch (using .0075 inch narrow element)

An optional check character can be used for applications requiring higher levels of data security. When used, the check character immediately follows the last data character. The check digit is calculated as follows:

A-3

Page 135

M3000 Portable Bar Code Reader User's Guide 1.

Each data character is assigned a numerical value as shown in the following table: CHAR

VALUE

CHAR

VALUE

CHAR

VALUE

0 1 2 3 4 5 6 7 8 9 A B C D E

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

F G H I J K L M N O P Q R S T

15 16 17 18 19 20 21 22 23 24 25 26 27 28 29

U V W X Y Z . SPACE $ / + %

30 31 32 33 34 35 36 37 38 39 40 41 42

2.

Sum all of the numerical values for each data character in the bar code.

3.

Divide this sum by 43.

4.

The remainder is the numerical value for the check digit. Use the table in step 1 to lookup the corresponding character.

EXAMPLE: Sample Code 39 data = A394T 1. 2. 3. 4.

A-4

Use the table to lookup the numerical value for each character. 10 + 3 + 9 + 4 + 29 = 55 55 / 43 = 1 remainder 12 Check digit numerical value = 12 The check digit = C. Bar code with check digit = A394TC

Page 136

Appendixes

APPENDIX C - FULL ASCII EXTENSION TO CODE 39 The FULL ASCII EXTENSION expands standard CODE 39 to include the entire 128 ASCII character set. This is accomplished by pairing standard CODE 39 characters. The $, +, /, and % characters are paired as shown in the following table:

ASCII

CODE

ASCII

CODE

ASCII

CODE

ASCII

CODE

NUL

%U

!

/A

A

A a

+A

SOH

$A

"

/B

B

B b

+B

STX

$B

#

/C

C

C c

+C

ETX

$C

$

/D

D

D d

+D

EOT

$D

%

/E

E

E e

+E

TB

$E

&

/F

F

F f

+F

ACK

$F

'

/G

G

G g

+G

BEL

$G

(

/H

H

H h

+H +I

BS

$H

)

/I

I

I i

HT

$I

*

/J

J

J j

+J

LF

$J

+

/K

K

K k

+K

VT

$K

,

/L

L

L l

+L

FF

$L

-

-

M

M m

+M

CR

$M

.

.

N

N n

+N

SO

$N

/

/O

O

O o

+O

SI

$O

0

0 or /P

P

P p

+P

DLE

$P

1

1 or /Q

Q

Q q

+Q

DC1

$Q

2

2 or /R

R

R r

+R

DC2

$R

3

3 or /S

S

S s

+S

DC3

$S

4

4 or /T

T

T t

+T

DC4

$T

5

5 or /U

U

U u

+U

NAK

$U

6

6 or /V

V

V v

+V

SYN

$V

7

7 or W

W

W w

+W

ETB

$W

8

8 or X

X

X x

+X

CAN

$X

9

9 or Y

Y

Y y

+Y

EM

$Y

:

/Z

Z

Z z

+Z

SUB

$Z

;

%F

[

%K

{

%P

ESC

%A

<

%G

\

%L

¦

%Q

FS

%B

=

%H

]

%M

}

%R

GS

%C

>

%I

^

%N

~

%S

RS

%D

?

%J

_

%O

DEL

%T, %X,

US

%E

@

%V

`

%W

SP

SPACE

%Y or %Z

EXAMPLE: When Full ASCII Extension to CODE 39 is enabled by M3000 Setup , "$M" is read as a Carriage Return. A-5

Page 137

M3000 Portable Bar Code Reader User's Guide

APPENDIX D - UPC SPECIFICATIONS The Universal Product Code (UPC) symbols can be found on almost all retail products today. The UPC coding system was designed to uniquely identify a product and its manufacturer.

UPC VERSION A UPC-A is a fixed length (12 digits) numeric only code with the following features:

UPC-A BAR CODE The NUMBER SYSTEM CHARACTER indicates the type of product the symbol is identifying: 0,7 2 3 4 5 1,6,8,9

Regular UPC codes with numbers assigned by the Uniform Code Council Random-weight items such as meat and produce. National Drug Code and National Health Related Items Code. For in-store marking of non-food items. Reserved for coupons. Reserved for future use.

The last digit in UPC bar codes is a MODULO 10 CHECK DIGIT. It is calculated in the following manner: 1.

From right to left, sum the digits in the odd positions.

2.

Multiply this sum by 3.

3.

From right to left, sum the digits in the even positions.

4.

Add this sum to the product of step 2.

5.

The modulo-10 check digit is the smallest number, which when added to the sum of Step 4 produces a multiple of 10.

EXAMPLE: UPC bar code = 01234567890C where C is the CHECK DIGIT. 1. 2. 3. 4. 5.

Sum 0 + 8 + 6 + 4 + 2 + 0 = 20 Multiply 20 x 3 = 60 Sum 9 + 7 + 5 + 3 + 1 = 25 Sum 60 + 25 = 85 85 + 5 = 90 (check digit = 5)

Therefore: UPC bar code - 012345678905

A-6

Page 138

Appendixes

UPC VERSION E UPC Version E is a six digit variation of the UPC symbology. The last digit indicates the type of compression used. Because of this data compression process, the version E symbol is often referred to as a zero-suppressed symbol. The following table illustrates the expansion process for converting UPC-E to its UPC-A equivalent: Version E Number

Insertion Digits

Insertion Location

Resultant Version A

XXXXX0 XXXXX1 XXXXX2 XXXXX3 XXXXX4 XXXXX5 XXXXX6 XXXXX7 XXXXX8 XXXXX9

00000 10000 20000 00000 00000 0000 0000 0000 0000 0000

Position 3 Position 3 Position 3 Position 4 Position 5 Position 6 Position 6 Position 6 Position 6 Position 6

XX00000XXX XX10000XXX XX20000XXX XXX00000XX XXXX00000X XXXXX00005 XXXXX00006 XXXXX00007 XXXXX00008 XXXXX00009

VERSION E

VERSION A EQUIVALENT

UPC/EAN SUPPLEMENTS UPC and EAN bar codes can contain supplements that provide two or five digits of additional information. The supplements are located to the right of standard UPC/EAN labels. The reader can be programmed to either read or ignore the supplements.

APPENDIX E - EAN SPECIFICATIONS The European Article Numbering system (EAN) is a superset of UPC. EAN has two versions: EAN-13 (13 digits) and EAN-8 (8 digits).

Country codes 00, 01, 03, 04, and 06 - 09 are assigned to the U.S. for compatibility with UPC.

A-7