Page 119

M3000 Portable Bar Code Reader User's Guide

Function Search Errors Message

Definition

Solution

Complete Input Before Searching

You attempted a FUNC SEARCH before completing minimum input requirements for the current field. You attempted a FUNC SEARCH before completing all inputs of an inserted record.

Continue to enter data until minimum input requirements are satisfied.

Complete Record Before Searching

Complete all remaining inputs before attempting FUNC SEARCH

Lookup/Data File Errors During FUNCTION TRANSMIT Message

Definition

Solution

Field Length

The data field contains more than 250 characters The file does not have a valid ID in the file header definition. Received file does not have a valid name. The received data file does not have a valid program name, or the program does not reside in memory. The received data file does not have the correct number of header inputs.

Reduce the size of the data string.

File ID Error File Name Error Pgm Name Error

File Format ERR

Use a valid ID. Valid ID's are: L, l, D, d File names must be 1 to 8 characters in length. File names must be 1 to 8 characters in length. Create or load the program into M3000 memory. Ensure that data file structure matches program input file structure.

Serial Input Error Messages Message

Solution

Serial Data Too Short For Input Serial Data Too Long For Input Serial Data Not Valid For Input

Ensure serial device is scanning , measuring, or otherwise outputting valid information. Ensure serial device is scanning , measuring, or otherwise outputting valid information. Take action necessary to ensure serial device is scanning, measuring, or otherwise outputting valid information.

9-4

Page 120

9Troubleshooting

Input Error Message while Using Lookup Tables Message

Solution

Input Not Found In Lookup Table Lookup File Is Not In Memory Input Not Found In Lookup File Input Not Found Accept Anyway?

Ensure input data matches one of the lookup table entries. Download the lookup file using, FUNCT + XMIT, Receive ASCII Files. Enter or scan only valid data. Enter or scan valid data, or answer 'Yes' to accept the data.

Troubleshooting Guide Problem PC Keyboard does not operate after disconnecting the M3000 from the Keyboard Wedge Cable

Definition Shunt is not connected to M3000 Y-Cable connector.

The 25-pin serial connector does not fit my PC's 9-pin input.

Connector mismatch.

No data from M3000 Keypad. Difficulty scanning bar codes while using Laser/CCD scanner.

M3000 in non portable mode. Laser too close to bar code. Scanner too far from bar code. Scanner pointing angle incorrect.

M3000 does not accept special character or function key codes. Short battery life.

Formatting error while programming. Continous operation in RS232 Serial or Serial Wedge modes on battery power alone. Baud rate too fast. Protocol incorrect. No problem.

Losing data during serial communications. How do I select the proper XMODEM mode? 2 beeps at Power On and nothing is displayed M3000 locks up and will not shut off. NOTE: While in keyboard wedge mode the M3000 cannot be shut off.

LCD display error detected. M3000 Lock Up

Solution Connect M3000 shunt to Keyboard Wedge Y-Cable connector, or unplug Y-Cable and connect keyboard connector directly to PC. Connect 25-pin to 9-pin adapter to end of M3000 Serial or Serial Y-Cable. Normal condition. Scan within the guidelines specified for the scanner you are using. Adjust Laser/CCD Opts/Timeout Precede HEX valure by a "/". Use "//" to output a slash. Use External Power Supply. Automatic shut-off is disabled during non portable modes. Use slower baud rate. Select appropriate protocol. M3000 auto detects proper XMODEM mode, ie. Checksum, CRC. Call for service. 1. Turn off computer. 2. Disconnect M3000 from the computer. 3. Disconnect any external power supply and remove the 9V battery. 4. Reconnect 9V battery. 5. Press and hold down the N key and R key. Then press the ON key. The M3000 will power up showing the main display.

9-5

Page 121

10Specifications General Specifications Input Devices: Wand, CCD, 5V Laser, RS-232 Serial Keyboard:

54 key embossed tactile membrane keyboard with separate alpha and numeric keys.

Special Keys:

Function Keys F1-F10, Ctrl, Alt, Shift, Home, End, PgUp, PgDn, Ins, Del, Arrow Keys.

Display:

2x16 Super-Twist LCD (wide viewing angle)

Memory:

64K EPROM, 64K RAM with data compression and variable length fields

Date/Time:

Real-time clock supports date and time stamps

Bar Codes:

Code 39, Extended Code 39 (Full ASCII), Interleaved 2 of 5, UPC-A, UPC-E, EAN-8, EAN-13, UPC & EAN supplements, Code 128, Code 93, Code 11, CODABAR, MSI/Plessey

Serial

Baud rates: 300 - 38,400 Data bits: 7 or 8 Stop Bits: 1 or 2 Parity: ODD, EVEN, MARK, NONE Inter-character delay: 0 - 99 msec

Protocols:

RS-232: XON/XOFF, XMODEM, ASCII, HAYES Modem Serial Wedge: ASCII or PC-TERMINAL scan codes Keyboard Wedge: IBM PC/XT/AT or PS/2

Power:

Operating: 9V Alkaline battery or external power supply. Backup: Lithium battery for memory backup

Physical:

4.0"W x 7.5"L x 1.3"H, 14 oz.

Environmental:

Operating Temperature: 0°C to +50°C (+32°F to +120°F) Relative Humidity: 5% to 95% (non-condensing)

Warranty:

One year, 30-Day Money-Back Guarantee

External Power Supply Interface Connector, Female:

2.1mm X 5.5mm (9-12 VDC center negative)

+

_

10-1

Page 122

M3000 Portable Bar Code Reader User's Guide

Battery Performance INPUT DEVICE

RUN TIME

NO. OF DECODES

Hewlett-Packard HBCS-A300 Wand

65 Hours

More than 37,000

Opticon 2.3 Inch CCD

74 Hours

More than 44,000

Metrologic Instruments 941 Laser

13 Hours

More than 7,000

Symbol LS-2000 Laser

71 Hours

More than 42,000

Photographic Sciences PSC 5310 Laser

56 Hours

More than 33,000

NOTES: 1.

The M3000 ran continuously for the duration of each test using a standard EVEREADY ENERGIZER , 9V Alkaline battery.

2.

Test label was a standard 100% UPC-A bar code, read approximately once every six seconds.

3.

Above test results are not a guaranteed minimum, only typical results. Your results may vary due to battery condition, input device, ambient temperature, etc.

Input/Output Specifications Laser Interface:

Wand Interface:

10-2

PIN

SIGNAL

1 2 3 4 5 6 7 8 9

Sync Data Decode LED No Connection Trigger Head Enable Ground Shield Ground Power, +5V

PIN

SIGNAL

2 7 8 9

Data Ground Shield Ground Power

1

2 3 4 6

7

1

2 3 4 6

7

8

8

5 9

5 9

Page 123 read from a scan by OCR; it may hold reading errors

Keyboard Wedge "Y" Cable Wiring Diagram

10Specifications

26 Pin 5 Pin Din 5 Pin Din Connector Male Male Connector (End View) Computer Clock #26 AWG 1 Clock Computer Gnd e #24 AWG 2 Gnd 1 5 Computer Data #26 AWG 3 Data Computer +5V #24 AWG 4 | +5V 2 4 #26 AWG 5 | Spare 3 Wedge Detect Shield Shell 5 Pin Din 5 Pin Din Female Female Connector (End View) Keyboard Clock #26 AWG 1 Clock Keyboard Gnd #24 AWG 2 Gnd 5 1 Keyboard Data #26 AWG 3 Data Keyboard +5V #24 AWG 4 | +5V 4 2 #26 AWG 5 Spare 3 e Shield Shell RS232 Serial Cable Wiring Diagram M3000 IBM PC

26 Pin Connector

25 Pin Female

TXD (Transmit Data

TXD (Transmit Data) RXD

RTS (Request to Send CTS (Clear to Send DSR (Data Set Ready)

) RXD (Receive Data) ) )

ao ao w nN

Receive Data) RTS CTS (Clear to Send)

DSR (Data Set Ready)

( ( (Request to Send) (

Signal GND

CD (Carrier Detect)

DTR (Data Terminal Ready) re) Shell

Yt

Signal GND CD (Carrier Detect) DTR (Data Terminal Ready)

an oa RN W

TT

Shell

10-3

Page 124 read from a scan by OCR; it may hold reading errors

M3000 Portable Bar Code Reader User's Guide

Serial Wedge "Y" Cable Wiring Diagram

M3000 26 Pin Connector

Terminal RXD 11

Term 25 Pin inal Male

Terminal TXD 19

25

17

16

Signal Gnd 2%

20 an Oo on KR WD

18

20

Shell

Host 25 Pin Female

Host TXD 2 Host RXD

24

Signal Gnd | 43

21 ant nao BR WwW DY

Shell ®

Modem Cable Wiring Diagram

Shell

TXD

RTS CTS

Sign

Modem

TXD (Transmit Data)

RXD (ReceiveData)

RTS (Request to Send) CTS (Clear to Send)

DSR (Data Set Ready) Signal Gnd

CD (Carrier Detect)

DTR (Data Terminal Ready)

(Transmit Data)

RXD (Receive Data)

(Request to Send) (Clear to Send)

DSR (Data Set Ready)

al Gnd

CD (Carrier Detect) DTR (Data Terminal Ready)

25 Pin Male oanr noah WN

M3000 26 Pin Connector TXD (Transmit Data) 2 RXD (Receive Data) 3 RTS (Request to Send) 8 CTS (Clear to Send) 5 DSR (Data Set Ready) 6 Signal GND | 13 CD (Carrier Detect) 7 DTR (Data Terminal Ready) 9 Shell

Shell

TXD (Transmit Data)

RXD (Receive Data)

RTS (Request to Send) CTS (Clear to Send)

DSR (Data Set Ready) Signal GND

CD (Carrier Detect)

DTR (Data Terminal Ready}

10-4

Page 125 read from a scan by OCR; it may hold reading errors

Keyboard Wedge Shunt Wiring Diagram

26 Pin Connector nN DO OO BR WD = nn 12. - - 13

15 16 17

18 19

20 21 |

22 e

23

24

25 |

26 Shell

10Specifications

26 Pin Connector (Solder View)

1 9 eeeeeeee¢e 10 ee eee @ @ ee @ f18 eeee#e8e¢8 @ 19 26

10-5

Page 126

11Maintenance Introduction With proper care the M3000 should provide years of trouble-free operation. The following provides general information on the care and upkeep of the unit.

Battery Replacement Depending on operating conditions, the 9V Alkaline battery should provide from 10 to 70 hours of operation. When the battery power drops below an acceptable level the M3000 prompts:

Battery Low Press Any Key To replace the battery: 1.

Place the M3000 face down as shown in the following illustration.

2.

Press down on the battery compartment cover, and slide the cover away from the case of the M3000.

3.

Carefully lift the battery from the case.

4.

Un-snap the old battery and replace with a new, 9-Volt Alkaline battery.

5.

Replace the battery cover.

11-1

Page 127

M3000 Portable Bar Code Reader User's Guide

EPROM Replacement 1.

Disconnect any cables, scanning devices and power supplies from the M3000 portable.

2.

Turn on the M3000. Press the EXIT key until the display shows:

Portable Mode Select Function and then shut the M3000 off. NOTE: This is a very important step and will prevent loss of any data or programs 3.

Turn the M3000 upside down and remove the four screws from the bottom of the case. Return the M3000 back to the upright position.

4.

Lift the top half of the M3000 case straight up until the four plastic posts have cleared the circuit board. Next, fold the top of the case back until the keyboard is facing downward. NOTE: Do not disconnect the keyboard.

5.

Carefully lift the circuit board up out of the M3000 lower case and fold it over on the top part of the case that you removed earlier. NOTE: The battery wires still connect the circuit board to the lower case - do not disconnect the battery wires.

6.

Locate the EPROM chip that has the white label on top. Using a small slot head screwdriver - carefully pry the chip from the socket.

Dimple on This End of EPROM

M3000 EPROM Alignment 7.

Take the new version EPROM chip and insert it into the socket with the dimple in the end of the chip facing the outer edge of the circuit board. If the pins of the chip do not line up with the socket, you may need to bend the chip's pins slightly to align them with the the socket. Press the EPROM chip firmly into place. NOTE: Sometimes if the pins are not aligned correctly, the pins will bend out or in, and will not make proper contact with the socket.

11-2

8.

Verify that all EPROM pins are inserted into the socket

9.

Carefully re-assemble the M3000 portable unit making sure that the battery cables do not get pinched between the circuit board and the battery compartment.

Page 128

11Maintenance

Avoiding Damage The M3000 can be damaged by any of the following conditions:

Electrical The electronic components of the M3000 can be damaged by exposure to intense electrical fields. If possible, avoid exposing the unit to the following conditions: •

Electrostatic discharge produced by friction. For example, heavily carpeted areas during periods of low humidity.

•

Avoid using the M3000 with a Modem during electrical storms.

•

Avoid exposure to any source of intense arcing.

•

Exposure to powerful electromagnetic fields. For example, large motors, induction coils, transformers, etc.

•

Exposure to sources of ionizing radiation. For example, nuclear reactors, x-rays, etc.

Mechanical Avoid the following: •

Direct exposure to water. Do not immerse.

•

Severe drops or physical impact.

•

Extreme heat or open flame. For example, do not leave on the dash board or inclosed in a vehicle.

•

Highly corrosive environments

•

Strong industrial cleaning solvents

Cleaning When the unit needs cleaning, use only a soft cloth, dampened in clean warm water. Do not use petroleum based solvents, or powerful detergents.

.

11-3