Page 11

EAN 0) EAN DECODER ON* Enable reading EAN-8 and EAN-13 labels. OFF Disable reading EAN-8 and EAN-13 labels. 1) ZERO FILL EAN-8 TO EAN-13 ON Add five leading zeroes to EAN-8 labels. After conversion, the M2800 will follow the EAN-13 programming options. OFF* No conversion is performed. 2) SEND EAN-13 COUNTRY CODE ON* Transmit the EAN-13 Country Code. OFF Do not transmit the EAN-13 Country Code. 3) SEND EAN-8 COUNTRY CODE ON* Transmit the EAN-8 Country Code. OFF Do not transmit the EAN-8 Country Code. 4) SEND EAN-13 CHECK DIGIT ON* Transmit the EAN-13 Check Digit character. OFF Do not transmit the EAN-13 Check Digit character. 5) SEND EAN-8 CHECK DIGIT ON* Transmit the EAN-8 Check Digit character. OFF Do not transmit the EAN-8 Check Digit character. 6) ISBN CONVERSION ON Convert 13 digit Bookland/EAN (978 prefix) to its corresponding 10 digit ISBN number. EXAMPLE: BAR CODE DATA = 9780806957906 ISBN OUTPUT DATA = 0806957905 OFF* Do not convert Bookland/EAN to an ISBN number. UPC/EAN SUPPLEMENTS 0) SUPPLEMENTS DECODER ON Enable reading UPC & EAN supplements. OFF* Disable reading UPC & EAN supplements. 1) ALLOW 2 DIGIT ON* Enable reading 2 digit supplements. Option 0 above must be set on. OFF Disable reading 2 digit supplements. 2) ALLOW 5 DIGIT ON* Enable reading 5 digit supplements. Option 0 above must be set on. OFF Disable reading 5 digit supplements. 3) REQUIRE SUPPLEMENTS Specifies how the M2800 will handle various supplements. 0)* None: UPC/EAN bar codes will be read with or without valid supplements. 1) UPC bar codes will not be read unless they are accompanied by a valid supplement. 2) EAN bar codes will not be read unless they are accompanied by a valid supplement. 3) Bookland EAN bar codes will not be read unless they are accompanied by a valid supplement. 4) All UPC/EAN bar codes will not be read unless they are accompanied by a valid supplement. 4) SEND SEPARATOR SPACE ON Insert a space between the standard bar code data and the supplemental data. OFF* No separator space is inserted. INTERLEAVED 2 OF 5 0) I 2 OF 5 DECODER ON* Enable reading Interleaved 2 of 5 labels. OFF Disable reading Interleaved 2 of 5 labels. 1) Check Digit: 0=None, 1=USS, 2=OPCC Specifies which type of check digit will be used with Interleaved 2 of 5: 0)* None (no check digit required) 1) Uniform Symbology Specification (USS) (3-1-3 Mod 10) 2) Optical Product Code Council (OPCC) (2-1-2 Mod 10) Model M2800 USB Bar Code and Magnetic Card Reader 2005 American Microsystems, Ltd. All Rights Reserved 2190 Regal Parkway • Euless, TX 76040 Phone 817.571.9015 • Fax 817.571.6176 Web Address: www.amltd.com

Page: 11

Page 12

2) SEND CHECK DIGIT ON Transmit the Interleaved 2 of 5 check digit with the bar code data. OFF* The check digit is not transmitted. 3) FIXED LENGTH ON Read only fixed length Interleaved 2 of 5 bar code labels that match the lengths defined in options 4 & 5 below. The check digit can be on or off. OFF* Disable Fixed Length mode. Read all Interleaved 2 of 5 labels without regard to length. 4) SET FIXED LENGTH #1 (02-60) Sets the first valid fixed length for Interleaved 2 of 5. Scan a two digit value to enter the length. Valid lengths are 02 to 60 characters. By definition, the length of Interleaved 2 of 5 labels are an even number of characters. The default fixed length is 6 characters. 5) SET FIXED LENGTH #2 (02-60) Sets a second valid fixed length for Interleaved 2 of 5. Scan a two digit value to enter the length. The default length is set to 0 characters (i.e. the second fixed length is disabled). CODABAR 0) CODABAR DECODER ON * Enable reading Codabar labels. OFF Disable reading Codabar labels. 1) SEND START/STOP ON Transmit the Codabar start/stop characters. OFF * Do not transmit the Codabar start/stop characters. 2) CLSI FORMATTING ON The M2800 will insert a blank after the 1st, 5th, and 10th characters of a 14-character Codabar label. The label length does not include the start and stop characters. OFF* Disable CLSI formatting. 3) CLSI CHECK DIGIT ON Enable the CLSI check digit. When this option is enabled, all fourteen digit numeric bar codes must contain a valid check digit. OFF* Disable the CLSI check digit. Check digit verification will not be performed. CODE 128 / EAN-128 0) CODE 128 DECODER ON * Enable reading Code 128 labels. OFF Disable reading Code 128 labels. 1) UCC-128 VERIFICATION ON A valid mod 10 check digit is required on UCC-MOD 10 bar codes. (Applies to 20-digit serial shipping container bar codes.) OFF * UCC-MOD 10 bar codes are accepted without valid mod check digit. 2) SEND MOD 10 CHECK DIGIT ON * Transmit the mod 10 check digit with the bar code entry. OFF Do not transmit the mod 10 check digit. 4) SEND EAN-128 ID ON Send EAN-128 EAN type identifier ]C1 OFF * Do not send EAN-128 EAN type identifier 5) EAN-128 GS CHARACTER (CHART) The group separator (<GS>, ASCII 29) is used by EAN-128 to separate sub-strings within a larger bar code, and is most commonly used on postal shipping labels. This character can be mapped to any ASCII character using the chart. (Default = GS)

Model M2800 USB Bar Code and Magnetic Card Reader 2005 American Microsystems, Ltd. All Rights Reserved 2190 Regal Parkway • Euless, TX 76040 Phone 817.571.9015 • Fax 817.571.6176 Web Address: www.amltd.com

Page: 12

Page 13

CODE 93 0) CODE 93 DECODER ON* Enable reading Code 93 labels. OFF Disable reading Code 93 labels. 1) CONCATENATE MODE ON Enable Concatenate Mode. The concatenate mode allows the M2800 to concatenate multiple bar codes in its buffer, then send them to the computer just like they were a single bar code. When a Code 93 label with a leading space is read, the M2800 emits two short beeps and buffers the data without transmission. This process continues until a Code 93 label without a leading space is read or 128 characters are buffered. A Code 93 bar code label that only contains a single or multiple dashes (minus sign) will clear the buffer. OFF* Disable Concatenate Mode. CODE 11 0) CODE 11 DECODER ON Enable reading Code 11 labels. OFF * Disable reading Code 11 labels. 1) TWO CHECK DIGITS REQUIRED ON Two valid check digits are required for each label. OFF * One valid check digit is required for each label. 2) SEND FIRST CHECK DIGIT ON Transmit the first check digit. OFF * Do not transmit the first check digit. 3) SEND SECOND CHECK DIGIT ON Transmit the second check digit. OFF * Do not transmit the second check digit. MSI/PLESSEY 0) MSI/PLESSEY DECODER ON Enable reading MSI/Plessey labels. OFF * Disable reading MSI/Plessey labels. 1) TWO CHECK DIGITS REQUIRED ON Two valid check digits are required for each label. The first check digit is defined by option 2 below. The second check digit is always mod 10. OFF * One valid check digit is required for each label. The check digit must be mod 10. 2) FIRST CHECK DIGIT MOD 11 ON The first check digit must be mod 11. OFF * The first check digit must be mod 10. 3) SEND FIRST CHECK DIGIT ON Transmit the first check digit. OFF * Do not transmit the first check digit. 4) SEND SECOND CHECK DIGIT ON Transmit the second check digit. OFF * Do not transmit the second check digit. 5) ISBN PLESSEY ON Enable reading of Modified Plessey ISBN bar codes. Only eleven digit ISBN bar codes will be read. OFF* Do not read Modified Plessey ISBN bar codes.

Model M2800 USB Bar Code and Magnetic Card Reader 2005 American Microsystems, Ltd. All Rights Reserved 2190 Regal Parkway • Euless, TX 76040 Phone 817.571.9015 • Fax 817.571.6176 Web Address: www.amltd.com

Page: 13

Page 14

RSS SYMBOLOGIES 0) RSS14 Decoder (both Linear and Stackable types) ON* Enable reading RSS14 labels. OFF Disable reading RSS14 labels. 1) RSS Limited Decoder ON Enable reading RSS Limited labels. OFF* Disable reading RSS Limited labels. 2) RSS Expanded Decoder (both Linear and Stackable types) ON Enable reading RSS Expanded labels. OFF* Disable reading RSS Expanded labels. 3) Send EAN Type Identifier (applies to all: RSS14, RSS Limited, RSS Expanded) ON Send EAN type identifier ([e0) before barcode OFF* Do not send EAN type identifier 4) Send Application Id (AI) (applies to all: RSS14, RSS Limited, RSS Expanded) ON* Send Application ID (01) before barcode OFF Do not send Application ID 5) Send Linkage Digit (applies to all: RSS14, RSS Limited, RSS Expanded) Note: This feature is not officially part of the RSS spec. It allows a flag (yes=1 or no=0) to be sent if the RSS bar code is part of a composite 2D bar code. Does not decode the 2D composite portion of the bar code. ON Send the Linkage Digit OFF* Do not send the Linkage Digit 6) Send Check Digit (applies to all: RSS14, RSS Limited, RSS Expanded) ON* Send the Check Digit OFF Do not send the Check Digit

SERIAL PORT #1 The M2800's RS-232 serial port accepts serial input data and re-transmits it to the computer through the keyboard interface. 0) MODE: 0=BATCH, 1=PASS THROUGH This option selects the mode of operation for serial input port. 0)* Selects the Batch Mode of operation. The M2800 buffers the data until it finds a valid record terminator character or a timeout occurs. The serial buffer can contain a maximum of 256 characters. The serial Preamble and Postamble can be used. (See options 2, 3, 4, and 5 for more information on Record Terminator and Timeout Delay.) 1)

Selects the Pass Through Mode of operation. The M2800 simply transmits each character that it receives from the serial port to the computer. Note that with MODE 1, the Preamble, Postamble, record terminator character, and timeout delay are not used.

1) PROTOCOL: 0=NONE, 1=XON/XOFF 0)* No flow control protocol is used. The serial buffer can contain a maximum of 256 characters. 1) XON/XOFF Protocol is selected. In this mode, the M2800 will transmit an XOFF (control S) character to stop incoming serial data. This prevents the serial buffer from overflowing. Once the M2800 has finished typing and is ready to accept more data, an XON (control Q) character will be transmitted to enable reception of more serial data. The XOFF will be transmitted when the buffer fills to 128 characters.

Model M2800 USB Bar Code and Magnetic Card Reader 2005 American Microsystems, Ltd. All Rights Reserved 2190 Regal Parkway • Euless, TX 76040 Phone 817.571.9015 • Fax 817.571.6176 Web Address: www.amltd.com

Page: 14

Page 15

2) RECORD TERMINATOR CHAR ON Valid only if option 0 is set for Batch Mode. The M2800 will search for the record terminator character, defined with option 4, which indicates the end of the data. There are two ways to trigger the transmission of the serial data buffer: (1) the M2800 detects the record terminator character or, (2) a timeout occurs. OFF* The M2800 will wait for a timeout before sending the serial data buffer out the keyboard interface. No check will be made for a record terminator character. 3) SEND RECORD TERMINATOR CHAR ON Transmit the record terminator character along with the serial data buffer. OFF* Do not transmit the record terminator character. Send only the serial data buffer. 4) ENTER RECORD TERMINATOR CHAR This option valid only if option 0 is set to Batch Mode and option 2 is enabled. The record terminator character can be scanned from the Full ASCII Chart on the back of the menu. This character is used to identify the end of the serial data stream. Once the M2800 detects this character, the buffered data is transmitted in a block to the computer through the keyboard interface. The default is a Carriage Return. 5) TIMEOUT DELAY (0.0 - 9.9 SEC) This parameter defines the maximum period allowed to elapse before the M2800 assumes the transmission has ended. The timer is activated on receipt of the first character from the serial input port. Any incoming character that arrives before the timeout occurs will reset the timer. The timeout delay can be programmed from 0.0 to 9.9 seconds in increments of 0.1 seconds. The default setting is 0.0 seconds. (To select a value, for example, 2.0, scan the 2 label, then the "0" label.) NOTE: Timeout Delay is used as a host response timeout delay when host response mode is enabled, at which point, the delay is from 0-99 seconds. 6) ENTER SERIAL COMMAND STRING This option allows bar code data to be redirected out the serial port instead of the keyboard interface. When the start of the bar code data matches the Command String, the M2800 will strip the Command String from the bar code data and then transmit the remaining data out the serial port instead of the keyboard interface. This feature is especially useful for interrogating electronic scales with RS-232C serial interfaces. To define this Command String, scan up to 5 characters from the Full ASCII Chart on the M2800 Setup Menu and then scan the ON bar code when finished, or scan OFF to erase or disable the string. 7) Serial Data Special/Function Keys ON* This option allows some non-printable ASCII data to be sent as PC keyboard keys. See Special/Function keys for a description of implementation. For example: converts ASCII 13 (CR) to USB Enter Key. OFF No conversion, key sent as CTRL-Shift-ASCII (i.e. Ctrl-Shift-M for CR)

SERIAL PORT #2 BAUD RATE The baud rate sets the data transmission speed for the serial input port on the M2800. The M2800’s baud rate must match the serial input device (electronic scale, portable terminal, etc.). Select one of the following: 0) 1200 1) 2400 2) 4800 3)* 9600 4) 19,200

Model M2800 USB Bar Code and Magnetic Card Reader 2005 American Microsystems, Ltd. All Rights Reserved 2190 Regal Parkway • Euless, TX 76040 Phone 817.571.9015 • Fax 817.571.6176 Web Address: www.amltd.com

Page: 15

Page 16

PARITY Sets the parity for the incoming serial data. This setting must match the serial input device (electronic scale, portable terminal, etc.). Select one of the following: 5)* N,8,1: None, 8 data bits, 1 Stop bit 6) E,7,1: Even, 7 data bits, 1 Stop bit 7) O,7,1: Odd, 7 data bits, 1 Stop bit 8) M,7,1: Mark, 7 data bits, 1 Stop bit MAG STRIPE OPTIONS #1 0) Send Account Number (valid only if option 3 is OFF) ON* Transmit the Account Number data from the magnetic card. On major credit cards, the account number is available on tracks 1 and 2. OFF Do not send the account information 1) Send name (valid only if option 3 is OFF) ON* Transmit the Name data on the magnetic card. The name is available only on Track 1. OFF Do not transmit name 2) Send Expiration Date (valid only if option 3 is OFF) ON* Send expiration date OFF Do not send expiration date. 3) Send All Track Data ON* Transmit ALL the data from each enabled track. The data is transmitted as it appears on the card with NO formatting; however, separator characters will be inserted between the fields. See options 4 and 6 for information on separator characters. OFF Disables this option 4) Enter the Track 1 Separator Character (valid only with option 3 ON) Chart Send the Separator Character. This separates the fields found when decoding a track in the Track 1 format. It is selectable from the full-ASCII menu chart. The default is “^”. 5) Format Expiration Date MMYY (valid only with option 3 OFF) ON Expiration date sent as MMYY OFF* Expiration date sent as YYMM 6) Enter Tracks 2 and 3 Separator Characters Chart Send the Separator Character. This separates the fields found when decoding a track in the Track 2 or 3 formats. It is selectable from the full-ASCII menu chart. The default is “=”.

MAG STRIPE OPTIONS #2 0) Output This option designates which track(s) will be output, and in what order. You may use a dual-track decoder in a single-track application by selecting FIRST TRACK (only) or SECOND TRACK (only). Select one of the following: 0) 1) 2)* 3)

First Track (only) Second Track (only) Both Tracks (output in order) Both Tracks (reverse order)

Note: The M2800 can auto-discriminate track data formats. It can read Track 1, Track 2, or Track 3 formats on the FIRST TRACK. It can also read Track 2 and Track 3 formats on the SECOND TRACK. Model M2800 USB Bar Code and Magnetic Card Reader 2005 American Microsystems, Ltd. All Rights Reserved 2190 Regal Parkway • Euless, TX 76040 Phone 817.571.9015 • Fax 817.571.6176 Web Address: www.amltd.com

Page: 16

Page 17

This would mean, for example, that a track 2 and 3 card would be read by the FIRST TRACK and SECOND TRACK, respectively. 1) Require Two Tracks ON Both tracks must decode successfully for a “good read” to occur. (Only valid for dual track readers) OFF* M2800 will accept one or more valid tracks as a “good read”. If OFF in a dual track application, it may allow a decode, even if only one track is successfully decoded. Use this setting for singletrack applications. 2) Send Start and End Sentinels (valid only if SEND ALL TRACK DATA is ON) ON* The Start/End sentinel characters for each enabled track will be transmitted. The characters for each enabled track will be transmitted. The characters for each type of sentinel are listed below: 1.) Track 1 start: “%” 2.) Track 2 and 3 start: “;” 3.) Track 1, 2, and 3 stop: “?” OFF

Do not transmit the Start/End Sentinel characters.

3) Between Track/Fields Termination Character The Character to be output is defined from the Terminator Character option. The default is a carriage return (USB Enter Key). ON

Transmit the Termination Character between each track/field that is read. The insertion location is according to the following: a) If the Send All Track Data option is ON, the character will be inserted between Tracks. b) If the Send All Track Data option is OFF, the character will be inserted between Fields. OFF * Do not transmit the Between Tracks/Fields Termination Character. 4) SEND ENDING TERMINATION CHARACTER The character to be output is defined from the Termination Character option. The default is a carriage return (ENTER). ON * Transmit the Termination Character after all data has been sent. OFF Do not transmit the Ending Termination Character. 5) STRIP SPACES (This option valid only if Send All Track Data is off.) ON * All spaces will be stripped from the Account Number Field, and any leading or trailing spaces will be stripped from the Name Field. OFF Do not strip any spaces from the mag stripe data. 6) Mag Stripe Data Special/Function Keys ON* This option allows some non-printable ASCII data to be sent as PC keyboard keys. See Special/Function keys for a description of implementation. For example: converts ASCII 13 (CR) to USB Enter Key. OFF No conversion, key sent as CTRL-Shift-ASCII (i.e. Ctrl-Shift-M for CR)

PREAMBLE Preamble refers to a user-defined set of characters transmitted at the beginning of each type of input data. There are three different preambles with one set each for bar code data, magnetic stripe data, and serial input port data. 0) ENTER BAR CODE PREAMBLE This set of user-defined characters is transmitted at the beginning of bar code data. To define this preamble, scan up to 15 characters from the Full ASCII Chart on the reverse side of the M2800 Setup Menu. Scan the ON bar code when complete. Scan OFF to completely erase or disable the preamble. Model M2800 USB Bar Code and Magnetic Card Reader 2005 American Microsystems, Ltd. All Rights Reserved 2190 Regal Parkway • Euless, TX 76040 Phone 817.571.9015 • Fax 817.571.6176 Web Address: www.amltd.com

Page: 17

Page 18

1) ENTER MAG STRIPE PREAMBLE This set of user-defined characters is transmitted at the beginning of mag stripe data. To define this preamble, scan up to 15 characters from the Full ASCII Chart on the reverse side of the M2800 Setup Menu. Scan the ON bar code when complete. Scan OFF to completely erase or disable the preamble. 2) ENTER SERIAL PORT PREAMBLE This set of user-defined characters is transmitted at the beginning of serial port data. To define this preamble, scan up to 15 characters from the Full ASCII Chart on the reverse side of the M2800 Setup Menu. Scan the ON bar code when complete. Scan OFF to completely erase or disable the preamble. 3) BAR CODE SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the bar code preamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 4) MAG SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the mag stripe preamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 5) SERIAL SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the serial port preamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 6) ACTIVE TYPES Specifies the types of bar codes that use preambles. Select one of the following: A Code 39 E EAN-8 I Code 93 M RSS14 B UPC-A F I 2 of 5 J MSI/Plessey N RSS Limited C UPC-E G Codabar K Code 11 O RSS Expanded D EAN-13 H Code 128 L ISBN X* All Bar Codes

POSTAMBLE Postamble refers to a user-defined set of characters transmitted at the end of each type of input data. There are three different postambles with one set each for bar code data, magnetic stripe data, and serial input port data. 0) ENTER BAR CODE POSTAMBLE This set of user-defined characters is transmitted at the end of bar code data. To define this postamble, scan up to 15 characters from the Full ASCII Chart on the reverse side of the M2800 Setup Menu. Scan the ON bar code when complete. Scan OFF to completely erase or disable the postamble. 1) ENTER MAG STRIPE POSTAMBLE This set of user-defined characters is transmitted at the end of magnetic stripe code data. To define this postamble, scan up to 15 characters from the Full ASCII Chart on the reverse side of the M2800 Setup Menu. Scan the ON bar code when complete. Scan OFF to completely erase or disable the postamble. 2) ENTER SERIAL PORT POSTAMBLE This set of user-defined characters is transmitted at the end of serial port data. To define this postamble, scan up to 15 characters from the Full ASCII Chart on the reverse side of the M2800 Setup Menu. Scan the ON bar code when complete. Scan OFF to completely erase or disable the postamble. 3) BAR CODE SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the bar code postamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds.

Model M2800 USB Bar Code and Magnetic Card Reader 2005 American Microsystems, Ltd. All Rights Reserved 2190 Regal Parkway • Euless, TX 76040 Phone 817.571.9015 • Fax 817.571.6176 Web Address: www.amltd.com

Page: 18

Page 19

4) MAG SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the mag stripe postamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 5) SERIAL SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the serial port postamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 6) ACTIVE TYPES Specifies the types of bar codes that use postambles. Select one of the following: A Code 39 E EAN-8 I Code 93 M RSS14 B UPC-A F I 2 of 5 J MSI/Plessey N RSS Limited C UPC-E G Codabar K Code 11 O RSS Expanded D EAN-13 H Code 128 L ISBN X* All Bar Codes

Model M2800 USB Bar Code and Magnetic Card Reader 2005 American Microsystems, Ltd. All Rights Reserved 2190 Regal Parkway • Euless, TX 76040 Phone 817.571.9015 • Fax 817.571.6176 Web Address: www.amltd.com

Page: 19

Page 20

TERMINATION CHARACTER The optional Termination Character is transmitted at the end of the data. If a user defined Termination Character is desired select option 4 below, then scan a single character from the Full ASCII section of the Setup Menu. 0) None 1) Horizontal Tab (ASCII 09) or (Special Keys On: USB Tab Key) 2)* Carriage Return (ASCII 13) or (Special Keys On: USB Enter Key) 3) USB Numeric Keypad Enter 4) User Defined Termination Character (from ASCII chart) SCAN BEEP Settings (0-3) set the length of the beep. Settings (4-7) set the tone (pitch) of the beep. Setting (8), when selected will override the other beep selections and shut the beep off. Length Tone 0) Short 4) Low 1) * Medium Short 5) Medium Low 2) Medium Long 6)* Medium High 3) Long 7) High 8) No Beep BAR CODE EDIT This option allows data editing (modification) before transmission. 0) DATA EDITING Must be on for any of the editing options below to be valid. ON: Enable Data Editing. OFF*: Disable Data Editing. 1) ENTER # OF LEADING CHAR TO STRIP (0-9, A-F) Refers to the number (0-15) of characters to be stripped or removed from the beginning of the bar code data. 2) ENTER # OF TRAILING CHAR TO STRIP (0-9, A-F) Refers to the number (0-15) of characters to be stripped or removed from the end of the bar code data. NOTE: If the total number of strip characters (both Leading and Trailing) is greater than the number of characters of the bar code, no characters will be stripped. 3) ENTER DATA TYPE TO EDIT Refers to the type of bar codes for which editing can be enabled, allowing editing to be specific to a type of bar code. The choices are listed below: A Code 39 E EAN-8 I Code 93 M RSS14 B UPC-A F I 2 of 5 J MSI/Plessey N RSS Limited C UPC-E G Codabar K Code 11 O RSS Expanded D EAN-13 H Code 128 L ISBN X* All Bar Codes 4) STRIP LEADING & TRAILING SPACES ON: Any Leading and Trailing Spaces will be stripped from the data. OFF*: No spaces will be stripped.

Model M2800 USB Bar Code and Magnetic Card Reader 2005 American Microsystems, Ltd. All Rights Reserved 2190 Regal Parkway • Euless, TX 76040 Phone 817.571.9015 • Fax 817.571.6176 Web Address: www.amltd.com

Page: 20