2) KEYBOARD AUTO CAPS/NUM LOCK With this option ON, data is automatically transmitted in the correct upper/lower case, whether the keyboard's settings are turned ON or OFF. ON *
Enable KEYBOARD AUTO CAPS/NUM LOCK.
OFF
Disable KEYBOARD AUTO CAPS
NOTE: The KEYBOARD AUTO CAPS/NUM LOCK option is NOT effective on some computers, such as XT's. Indications that this option is NOT functioning are as follows: Upper/Lower Case are reversed. SPECIAL KEY characters are not transmitted when SPECIAL KEYS are ON. If KEYBOARD AUTO CAPS/NUM LOCK is NOT operating properly on your system, take the following steps: Set KEYBOARD AUTO CAPS/NUM LOCK to OFF. Set KEYBOARD NUM LOCK STATUS. (See "Options #1", (7) ). Set KEYBOARD CAPS LOCK STATUS. (See (1), the preceding option.)
3) ALTERNATE KEYBOARD SCAN CODES This option is necessary ONLY for computers that use SCAN CODE Set 3. Note that it might be necessary to disable KEYBOARD AUTO CAPS/NUM LOCK. See (2), the preceding option, for further information. ON
Enable ALTERNATE KEYBOARD SCAN CODES.
OFF *
Disable ALTERNATE KEYBOARD SCAN CODES.
47
Page 52
4) MAG STRIPE SPECIAL / FUNCTION KEYS This option applies to MAG STRIPE data, preambles, postambles, and user-defined termination characters. ON
SPECIAL KEYS and FUNCTION KEYS will be transmitted in place of a specific set of ASCII characters. The SPECIAL and FUNCTION KEY values are listed in the Full ASCII Chart provided on back of the SETUP MENU and in Appendix A.
OFF *
Disable SPECIAL / FUNCTION KEYS. (Standard ASCII characters are transmitted.)
5) SERIAL DATA SPECIAL / FUNCTION KEYS This option applies to SERIAL data, preambles, postambles and user-defined termination characters. ON
SPECIAL KEYS and FUNCTION KEYS will be transmitted in place of a special set of ASCII Characters. The SPECIAL and FUNCTION KEY values are listed in the Full Ascii Chart provided on the back of the SETUP MENU and in Appendix A.
OFF *
Disable SPECIAL / FUNCTION KEYS. (Standard ASCII characters are transmitted.)
6) BAR CODE TERM CHAR OVERRIDE ON If any control character or special character (ie., function key, arrow key, etc...) is embedded in the bar code data, the TERMINATION CHARACTER, the BAR CODE PREAMBLE, and the BAR CODE POSTAMBLE will not be transmitted. OFF *
DIAGNOSTICS
The TERMINATION CHARACTER, the BAR CODE PREAMBLE, and the BAR CODE POSTAMBLE will be transmitted with all bar code data.
This option executes a self-test program which performs the following tests on the reader: * EPROM Version Number * Internal and External Ram Test * EPROM Checksum Test * Character Set Test * Buzzer Test The above tests are performed and their status is displayed on the PC monitor. NOTE: Exit your application program and return to DOS before enabling this test.
48
Page 53
CLONING SETUP INFORMATION When multiple readers are to be setup in the same configuration, it is advantageous to setup the first reader, and clone (copy) that setup to all the other units. The setup information can be (1), stored on a computer for cloning from computer to reader, or (2), cloned directly from one reader to another. These methods are described below:
CLONING FROM COMPUTER TO READER BEFORE YOU START, HAVE THE FOLLOWING EQUIPMENT READY: -
-
A PC CLONE CABLE (with a 9 pin plug (male) and a 25 pin socket (female)). A communication software package must be installed on your computer, and it must have the following configuration settings: BAUD RATE: must match the reader's setting DATA BITS: 8 bits The configured reader, which is to send the clone information, must have the following configuration setting: DATA BITS: 8 bits (the default setting)
NOTE: If the clone information has already been sent to your computer, start at step 10.
Step 1:
Start with the configured reader (denoted as the "SOURCE" reader) connected to the computer as a keyboard wedge.
Step 2:
Plug the 9 pin end of the PC CLONE CABLE into the SOURCE reader's connector labeled "RS-232 SERIAL PORT", located on the rear panel of the reader.
Step 3:
Scan the START bar code on the READER SETUP MENU.
Step 4:
Plug the other end of the PC CLONE CABLE (the 25 pin female) into the computer's RS-232 serial port.
Step 5:
At the computer, run your communications program and put it into RECEIVE mode.
49
Page 54
Step 6:
Scan the following "CLONE" bar code:
CLONE Step 7:
Once the clone information has been transmitted, take any steps required to save the information on the computer.
Step 8:
From the SOURCE reader, scan EXIT (saving OR ignoring changes) on the READER SETUP MENU.
Step 9:
Disconnect the SOURCE reader from all cables leading to the computer (the PC CLONE CABLE, the keyboard cable, and the computer keyboard port cable).
Step 10:
Plug the 9 pin end of the PC CLONE CABLE into the reader which is to receive the clone information (denoted as the "TARGET" reader). The TARGET reader's connector, located on the rear panel, is labeled "RS-232 SERIAL PORT".
Step 11:
Connect the TARGET reader as a keyboard wedge.
Step 12:
At the computer, run the communications program. Note that the communications BAUD RATE must be set to match the TARGET reader's BAUD RATE (the default setting is 9600).
Step 13:
Set the communications program to TRANSMIT. The reader will beep twice, pause, and beep three times more, indicating the following: 2 beeps: indicate the clone information was received 3 beeps: indicate the reader is now configured
Step 14:
Now you are ready to disconnect the newly configured reader from all cables leading to the computer. (The PC CLONE CABLE, the keyboard cable, and the computer keyboard port cable.)
Step 15:
Repeat steps 10 -14 for each additional reader to be cloned.
50
Page 55
CLONING FROM READER TO READER BEFORE YOU START, HAVE THE FOLLOWING EQUIPMENT READY: -
A READER CLONE CABLE (with two 9 pin male plugs). The two readers involved must each be connected as a keyboard wedge to a separate PC, and the power must be ON. The reader which is to receive the clone information must have the following configuration settings: BAUD RATE: must match the configured reader's setting DATA BITS: 8 bits (the default setting)
Step 1:
Plug one end of the READER CLONE CABLE into the configured reader (denoted as the "SOURCE" reader). The SOURCE's connector, located on the rear panel of the reader, is labeled "RS232 SERIAL PORT".
Step 2:
Plug the other end of the READER CLONE CABLE into the reader which is to receive the clone information; this reader is denoted as the "TARGET".
Step 3:
From the "SOURCE" reader, scan the START bar code on the READER SETUP MENU.
Step 4:
Still at the "SOURCE" reader, scan the following "CLONE" bar code:
CLONE Step 5:
The "TARGET" reader will beep twice, pause, and beep three times more, indicating it has received the clone information and is now configured.
Step 6:
Disconnect the CLONE CABLE from the newly configured TARGET reader.
Step 7:
For each additional reader to be cloned, connect a TARGET reader to a computer and repeat steps 2-6.
Step 8:
When cloning is complete, go to the SOURCE reader and scan EXIT (saving OR ignoring changes) on the READER SETUP MENU.
Step 9:
Next, disconnect the CLONE CABLE from the SOURCE reader. 51
Page 56
RS-232C SERIAL PORT The RS-232C serial port located on the rear panel of the reader accepts serial ASCII data and re-transmits it to the computer through the keyboard interface. The serial input data appears as though it was typed in from the computer keyboard. The connector pin assignments for the serial port interface are listed below: PIN 1 2 3 4 5,6 7 8,9
SIGNAL Signal Ground Transmit Data Receive Data Data Terminal Ready No Connection Signal Ground No Connection
DIRECTION N/A Output Input Output N/A
The serial input port will accept almost any type of RS-232C serial device such as: -
Electronic scales Table top laser scanners Side scan laser scanners Portable & fixed terminals
CONNECTING AN ELECTRONIC SCALE TO THE BAR CODE READER The M2000/2002 reader will interface with almost any electronic scale that has an RS-232C serial interface port. To connect an electronic scale to the bar code reader, perform the following steps: -
Connect a serial cable between the scale and the bar code reader's serial input port. Verify that the wiring of the serial cable is correct.
-
Program the bar code reader’s SERIAL PORT setting for PASS THROUGH MODE (see PROGRAMMING GUIDE section in this manual).
-
Program the bar code reader’s serial port parameters (BAUD RATE, PARITY, DATA BITS) to match the configuration of the scale.
52
Page 57
There are two basic types of scale interfaces: INTERFACE TYPE #1: With this type of scale interface the user presses a button (usually located on the scale's front panel) to transmit the scale data through the serial port. The bar code reader will receive this data from its serial input port, and then transmit the data to the computer through the keyboard interface. To the computer, the data appears to have come from the keyboard. INTERFACE TYPE #2: With this type of scale interface, a command must be sent to the scale to initiate data transfer. The bar code reader must be programmed with a SERIAL COMMAND STRING, as defined under "Serial Port", in the "Programming Guide" section. Once a command is received by the scale, data is transmitted out in the same manner as for "Interface Type #1".
EXAMPLE: Toledo 8213 BENCH SCALE (Interface Type #2) PROBLEM: To obtain weight data from the 8213 scale's serial port, which is to be sent to the computer appearing as keyboard input. SOLUTION: The 8213 will send the current weight reading if it receives an ASCII "W" through its serial port. First, program the bar code reader to recognize a "unique" SERIAL COMMAND STRING, i.e., "%A5A%" (5 characters maximum). Next, print a bar code that contains this SERIAL COMMAND STRING followed by a "W". Scan this bar code by the usual means (wand, CCD, or LASER). The bar code reader will beep, indicating a successful read. It will recognize the SERIAL COMMAND STRING at the beginning of the bar code data. Instead of transmitting the bar code data through the keyboard interface, as the reader would normally do, it will strip off the SERIAL COMMAND STRING and transmit only the "W", which will be directed through the serial port to the scale. The scale will receive the "W", recognize it as a request, and transmit its weight data through its serial port. The reader will receive the scale data and transmit it on to the computer through the keyboard interface. To the computer, the data appears to have come from the keyboard. (This entire process takes only a fraction of a second.) SCALE COMMAND TO TRANSMIT WEIGHT= W (UNIQUE) SERIAL COMMAND STRING = %A5A% Here is the example bar code:
%A5A%W
53
Page 58
SPECIFICATIONS BAR CODES SUPPORTED Auto-discriminates between all of the following codes: • Code 39 • • Extended Code 39 (Full ASCII) • • Interleaved 2 of 5 (Variable and Fixed Length, Check Digit) • • UPC-A (Including 2 and 5 Character Supplements) • • UPC-E(0), UPC-E(1) • • EAN (Including 2 and 5 Character Supplements)
Codabar Code 128 Code 93 Code 11 MSI/Plessey
INPUT DEVICES SUPPORTED Laser (Helium-Neon, Visible Laser Diode, Infrared) CCD Scanners Wands (Visible and Infrared) Slot Readers (Or Badge Readers) Magnetic Stripe Readers (Single or Dual Track) RS-232 Input Port (Electronic Scales, Portable Terminals) USER PROGRAMMABLE FEATURES All features are easily programmed with a bar code menu: Bar Code Selection: Preambles/Postambles: Laser Configuration: • Enable/Disable • Bar Code (15 Chars Max) • Laser Time-Out • Length • Mag Stripe (15 Chars Max) • Trigger Function • Check Digit • Serial Port (15 Chars Max) • Continuous Mode • Start/Stop Transmit • Transmit Delay Computer Type Beep Tone and Length Mag Stripe Data Format Transmit Speed RS-232 SERIAL PORT Baud Rates: 150, 300, 600, 1200, 2400, 4800, 9600, 19.2K Parity: NONE, ODD, EVEN, MARK Data Bits: 7 or 8 Signals: Transmit Data, Receive Data, Signal Ground, DTR Protocol: NONE, XON/XOFF Features: Programmable Termination Character and Timeout INDICATORS Audio "BEEP" Indicates Successful Read A Red/Green LED Indicates Status of Reader POWER REQUIREMENTS Reader Receives its Power from the Personal Computer Keyboard Interface. Power Consumption = 0.5 Watts. (12V Laser Requires External 12V Supply) ENVIRONMENTAL CONNECTORS Operating Temperature: 0o to +50o C Laser Input: 9 Pin "D" Style Storage Temperature: -30o to +70 o C Wand Input: 5 Pin DIN Style Relative Humidity: 5% to 95% Mag Stripe Input: 8 Pin DIN Style (Non-Condensing) Keyboard Interface: M2000 = 5 Pin DIN Style M2002 = 6 Pin MINI-DIN Style RS-232 Input: 9 Pin "D" Style External Power Input: 2.5 mm Barrel Connector PHYSICAL SPECIFICATIONS Weight: 14 Ounces Width: 5 1/8 Inches Length: 5 1/4 Inches Height: 1 1/2 Inches
54
Page 59
SIGNAL DEFINITIONS WAND/MAG STRIPE INTERFACE PIN 1 2 3 4 5
SIGNAL +5V DATA (DATA - MAG STRIPE) GROUND _____ CLOCK (MAG STRIPE) ___________ CARD PRESENT (MAG STRIPE)
5
1
4
2 3
DUAL MAG STRIPE INTERFACE PIN 1 2 3 4 5 6 7 8
SIGNAL +5V ____ DATA, _____TRACK 2 CLOCK, TRACK 2 GROUND ____ DATA, _____TRACK 1 CLOCK, TRACK 1 ___________ CARD PRESENT GROUND
8
7
1
6
2 5
3
4
LASER INTERFACE PIN 1 2 3 4 5 6 7 8 9
SIGNAL SYNC DATA DECODE LED NO CONNECTION TRIGGER HEAD ENABLE GROUND SHIELD GROUND LASER POWER
1
2
6
3
7
4
8
5
9
RS-232C SERIAL INPUT PORT PIN 1 2 3 4 5,6 7 8,9
SIGNAL SIGNAL GROUND TRANSMIT DATA RECEIVE DATA DATA TERMINAL READY NO CONNECTION SIGNAL GROUND NO CONNECTION
55
5
3
4
9
8
2
7
1
6
Page 60
SIGNAL DEFINITIONS (Cont) M2000 KEYBOARD/COMPUTER INTERFACE PIN 1 2 3 4 5
SIGNAL KEYBOARD CLOCK GROUND KEYBOARD DATA +5V SPARE
5
1
4
2
M2002 KEYBOARD/COMPUTER INTERFACE PIN 1 2 3 4 5 6
SIGNAL KEYBOARD DATA RESERVED GROUND +5V KEYBOARD CLOCK RESERVED
6 4
3
2
1
EXTERNAL POWER SUPPLY INTERFACE CONNECTOR: FEMALE BARREL 2.5mm x 5.5mm (9 - 12 VDC center positive)
+
-
NOTE: THE EXTERNAL POWER SUPPLY PROVIDES POWER TO THE LASER INTERFACE ONLY.