The text of a manual · part 4 of 9
Bar Code and Magnetic Stripe Reader Models 2000/2002 User's Manual, pages 31 to 40
Pages 31 to 40 of 82
The original document is the PDF (708 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the AML M2000
Page 31
UPC/EAN SUPPLEMENTS 0) SUPPLEMENTS DECODER ON Enable reading UPC & EAN supplements. OFF*
Disable reading UPC & EAN supplements.
1) ALLOW 2 DIGIT ON* Enable reading 2 digit supplements. above must be set ON. OFF
Disable reading 2 digit supplements.
2) ALLOW 5 DIGIT ON* Enable reading 5 digit supplements. above must be set ON. OFF
Option (0)
Option (0)
Disable reading 5 digit supplements.
3) REQUIRE SUPPLEMENTS Specifies how the reader will handle various supplements. 0)* UPC/EAN bar codes will be read with or without valid supplements. 1) UPC bar codes will not be read unless they are accompanied by a valid supplement. 2) EAN bar codes will not be read unless they are accompanied by a valid supplement. 3) Bookland EAN bar codes will not be read unless they are accompanied by a valid supplement. 4) All UPC/EAN bar codes will not be read unless they are accompanied by a valid supplement. 4) SEND SEPARATOR SPACE ON Insert a space between the standard bar code data and the supplemental data. OFF*
No separator space is inserted.
27
Page 32
INTERLEAVED 2 OF 5 0) I 2 OF 5 DECODER ON* Enable reading INTERLEAVED 2 of 5 labels. OFF
Disable reading INTERLEAVED 2 of 5 labels.
1) CHECK DIGIT: 0=NONE, 1=USS, 2=OPCC Specifies which type of check digit will be used with INTERLEAVED 2 of 5: 0* = NONE (no check digit required) 1 = UNIFORM SYMBOLOGY SPECIFICATION (3-1-3 MOD 10) 2 = OPTICAL PRODUCT CODE COUNCIL (2-1-2 MOD 10) 2) SEND CHECK DIGIT ON Transmit the INTERLEAVED 2 of 5 check digit with the bar code data. OFF*
The check digit is not transmitted.
3) FIXED LENGTH ON Read only FIXED LENGTH INTERLEAVED 2 of 5 bar code labels that match the lengths defined in options (4) & (5) below. The check digit can be on or off. OFF*
Disable FIXED LENGTH mode. Read all INTERLEAVED 2 of 5 labels without regard to length.
4) SET FIXED LENGTH #1 (02-60) Sets the first valid FIXED LENGTH for Interleaved 2 of 5. Scan a two digit value to enter the length. Valid lengths are 02 to 60 characters. By definition, the length of Interleaved 2 of 5 labels are an even number of characters. The default FIXED LENGTH is 6 characters. 5) SET FIXED LENGTH #2 (02-60) Sets a second valid fixed LENGTH for Interleaved 2 of 5. Scan a two digit value to enter the length. The default length is set to 0 characters (i.e. the second FIXED LENGTH is disabled).
28
Page 33
CODABAR 0) CODABAR DECODER ON * Enable reading CODABAR labels. OFF
Disable reading CODABAR labels.
1) SEND START/STOP ON Transmit the CODABAR start/stop characters. OFF *
Do not transmit the CODABAR start/stop characters.
2) CLSI FORMATTING ON The reader will insert a blank after the 1st, 5th, and 10th characters of a 14-character CODABAR label. The label length does not include the start and stop characters. OFF *
Disable CLSI formatting.
3) CLSI CHECK DIGIT ON Enable the CLSI check digit. When this option is enabled, all fourteen digit numeric bar codes must contain a valid check digit. OFF*
Disable the CLSI check digit. Check digit verification will not be performed.
CODE 128 0) CODE 128 DECODER ON * Enable reading Code 128 labels. OFF
Disable reading Code 128 labels.
1) UCC-128 VERIFICATION ON A valid MOD 10 CHECK DIGIT is required on UCCMOD 10 bar codes. (Applies to 20-digit serial shipping container bar codes.) OFF *
UCC-MOD 10 bar codes are accepted without valid MOD 10 CHECK DIGITS.
2) SEND MOD 10 CHECK DIGIT ON * Transmit the MOD 10 CHECK DIGIT with the bar code entry. OFF
Do not transmit the MOD 10 CHECK DIGIT.
29
Page 34
CODE 93 0) CODE 93 DECODER ON* Enable reading Code 93 labels. OFF
Disable reading Code 93 labels.
1) CONCATENATE MODE ON Enable CONCATENATE MODE. The concatenate mode allows the reader to concatenate multiple bar codes in its buffer, then send them to the computer just like they were a single bar code. When a Code 93 label with a leading space is read, the reader emits two short beeps and buffers the data without transmission. This process continues until a Code 93 label without a leading space is read or 128 characters are buffered. A Code 93 bar code label that only contains a single or multiple dashes (minus sign) will clear the buffer.
CODE 11
OFF*
Disable CONCATENATE MODE.
0) CODE 11 DECODER ON Enable reading CODE 11 labels. OFF *
Disable reading CODE 11 labels.
1) TWO CHECK DIGITS REQUIRED ON Two valid CHECK DIGITS are required for each label. OFF *
One valid CHECK DIGIT is required for each label.
2) SEND FIRST CHECK DIGIT ON Transmit the FIRST CHECK DIGIT. OFF *
Do not transmit the FIRST CHECK DIGIT.
3) SEND SECOND CHECK DIGIT ON Transmit the SECOND CHECK DIGIT. OFF *
Do not transmit the SECOND CHECK DIGIT.
30
Page 35
MSI/PLESSEY 0) MSI/PLESSEY DECODER ON Enable reading MSI/PLESSEY labels. OFF *
Disable reading MSI/PLESSEY labels.
1) TWO CHECK DIGITS REQUIRED ON Two valid CHECK DIGITS are required for each label. The first check digit is defined by option (2) below. The second check digit is always MOD 10. OFF *
One valid CHECK DIGIT is required for each label. The CHECK DIGIT must be MOD 10.
2) FIRST CHECK DIGIT MOD 11 ON The FIRST CHECK DIGIT must be MOD 11. OFF *
The FIRST CHECK DIGIT must be MOD 10.
3) SEND FIRST CHECK DIGIT ON Transmit the FIRST CHECK DIGIT. OFF *
Do not transmit the FIRST CHECK DIGIT.
4) SEND SECOND CHECK DIGIT ON Transmit the SECOND CHECK DIGIT. OFF *
Do not transmit the SECOND CHECK DIGIT.
5) ISBN PLESSEY ON Enable reading of Modified Plessey ISBN bar codes. Only eleven digit ISBN bar codes will be read. OFF*
Do not read Modified Plessey ISBN bar codes.
31
Page 36
SERIAL PORT The reader's RS-232C serial port accepts serial input data and retransmits it to the computer through the keyboard interface. 0) MODE: 0=BATCH, 1=PASS THROUGH This option selects the mode of operation for serial input port. 0*
Selects the BATCH MODE of operation. The reader buffers the data until it finds a valid RECORD TERMINATOR CHARACTER or a TIMEOUT occurs. The serial buffer can contain a maximum of 256 characters. The serial PREAMBLE and POSTAMBLE can be enabled with MODE 0. (See options (2), (3), (4), and (5) for more information on RECORD TERMINATOR and TIMEOUT DELAY.)
1
Selects the PASS THROUGH MODE of operation. The reader simply transmits each character that it receives from the serial port to the computer. Note that with MODE 1, the PREAMBLE, POSTAMBLE, RECORD TERMINATOR CHARACTER, and TIMEOUT DELAY have no effect on the serial data.
1) PROTOCOL: 0=NONE, 1=XON/XOFF 0* No PROTOCOL is used. The serial buffer can contain a maximum of 256 characters. 1
XON/XOFF PROTOCOL is selected. In this mode, the reader will transmit an XOFF (control S) character to stop incoming serial data. This prevents the serial buffer from overflowing. Once the reader is ready to accept more data, an XON (control Q) character will be transmitted to enable reception of more serial data. The XOFF will be transmitted when the buffer fills to 250 characters.
2) RECORD TERMINATOR CHAR ON (Valid only if option (0) is set for BATCH MODE.) The reader will search for the RECORD TERMINATOR CHARACTER, defined with option (4), which indicates the end of the data. There are two ways to trigger the transmission of the serial data buffer: (1) the reader detects the RECORD TERMINATOR CHARACTER or, (2) a TIMEOUT occurs. OFF *
The reader will wait for a TIMEOUT before sending the serial data buffer out the keyboard interface. No check will be made for a RECORD TERMINATOR CHARACTER. 32
Page 37
3) SEND RECORD TERMINATOR CHAR ON Transmit the RECORD TERMINATOR CHARACTER along with the serial data buffer. OFF *
Do not transmit the RECORD TERMINATOR CHARACTER. Send only the serial data buffer.
4) ENTER RECORD TERMINATOR CHAR (This option valid only if option (0) is set to BATCH MODE and option (2) is enabled.) The record terminator character can be scanned from the FULL ASCII CHART on the back of the menu. This character is used to identify the end of the serial data stream. Once the reader detects this character, the buffered data is transmitted in a block to the computer through the keyboard interface. The default is a Carriage Return. 5) TIMEOUT DELAY (0.0 - 9.9 SEC) This parameter defines the maximum period allowed to elapse before the reader assumes the transmission has ended. The timer is activated on receipt of the first character from the serial input port. Any incoming character that arrives before the timeout occurs will reset the timer. The TIMEOUT DELAY can be programmed from 0 to 9.9 seconds in increments of 0.1 seconds. The default setting is 0.0 seconds. (To select a value, for example, 2.0, scan the "2" label, then the "0" label.) NOTE: TIMEOUT DELAY is used as a host response timeout delay when host response mode is enabled, at which point, the delay is from 0-99 seconds. 6) ENTER SERIAL COMMAND STRING This option allows bar code data to be redirected out the serial port instead of the keyboard interface. When the start of the bar code data matches the COMMAND STRING, the reader will strip the COMMAND STRING from the bar code data and then transmit the remaining data out the serial port instead of the keyboard interface. This feature is especially useful for interrogating electronic scales with RS-232C serial interfaces. To define this COMMAND STRING, scan up to 5 characters from the FULL ASCII CHART on the MENU and then scan the "ON" bar code when finished. 7) READER OUTPUT This option defines how the reader will output all data. Select one of the following: 0* Keyboard output only. 1 Keyboard and RS-232 Serial output. 2 RS-232 Serial output only. 3 Keyboard and RS-232 Serial output using serial port preambles and postambles. 33
Page 38
8) SERIAL CONTROL: 0=NONE, 1=DAISY CHAIN, 2=HOST RESPONSE This option defines the control mode of the RS-232C serial port, which allows the M2000/2002 to be used as a daisy chain controller and also allows for a host response through the serial port. 0* 1 2
This is the normal mode of operation. M2000 operates as a stand alone unit. This mode allows multiple M2500 serial output decoders to be "daisy chained" into the serial port of the M2000. In this mode, M2000's can receive a serial response from the host computer after transmitting data. CR - data ok, no action needed CTRL G - single beep CTRL R - high/low error warble tone
NOTE: TIMEOUT DELAY is used as a host response timeout delay when host response mode is enabled.
BAUD RATE The BAUD RATE sets the data transmission speed for the serial input port on the reader. The reader’s BAUD RATE must match the serial input device (electronic scale, portable terminal, etc...). Select one of the following: 0 150 2 600 4 2400 6* 9600
1 3 5 7
300 1200 4800 19,200
PARITY Sets the PARITY for the incoming serial data. This setting must match the serial input device (electronic scale, portable terminal, etc...). Select one of the following: 0* NONE 1 EVEN 2 ODD 3 MARK
DATA BITS Sets the character length (number of DATA BITS per character) for the incoming serial data. This setting must match the serial input device (electronic scale, portable terminal, etc...). Select one of the following: 0 7 BITS 1* 8 BITS
34
Page 39
PREAMBLES PREAMBLE refers to a user-defined set of characters transmitted at the beginning of each type of input data. There are three different PREAMBLES; one set each for bar code data, magnetic stripe data, and serial input port data. 0) ENTER BAR CODE PREAMBLE This set of user-defined characters is transmitted at the beginning of BAR CODE data. To define this preamble, scan up to 15 characters from the FULL ASCII chart on the reverse side of the SETUP MENU. Scan the "ON" bar code when complete. 1) ENTER MAG STRIPE PREAMBLE This set of user-defined characters is transmitted at the beginning of MAG STRIPE data. To define this preamble, scan up to 15 characters from the FULL ASCII chart on the reverse side of the SETUP MENU. Scan the "ON" bar code when complete. 2) ENTER SERIAL PORT PREAMBLE This set of user-defined characters is transmitted at the beginning of SERIAL port data. To define this preamble, scan up to 15 characters from the FULL ASCII chart on the reverse side of the SETUP MENU. Scan the "ON" bar code when complete. 3) BAR CODE SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the BAR CODE preamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 4) MAG SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the MAG STRIPE preamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 5) SERIAL SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the SERIAL port preamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 6) ACTIVE TYPES Specifies the types of bar codes that use preambles. Select one of the following: A CODE 39 B UPC-A C UPC-E D EAN-13
E EAN-8 I CODE 93 F I 2 of 5 J MSI/PLESSEY G CODABAR K CODE 11 H CODE 128 L ISBN X* ALL BAR CODES
35
Page 40
POSTAMBLES POSTAMBLE refers to a user-defined set of characters transmitted at the end of each type of input data. There are three different postambles; one set each for bar code data, magnetic stripe data, and serial input port data. 0) ENTER BAR CODE POSTAMBLE This set of user-defined characters is transmitted at the end of BAR CODE data. To define this postamble, scan up to 15 characters from the FULL ASCII chart on the reverse side of the SETUP MENU. Scan the "ON" bar code when complete. 1) ENTER MAG STRIPE POSTAMBLE This set of user-defined characters is transmitted at the end of MAG STRIPE code data. To define this postamble, scan up to 15 characters from the FULL ASCII chart on the reverse side of the SETUP MENU. Scan the "ON" bar code when complete. 2) ENTER SERIAL PORT POSTAMBLE This set of user-defined characters is transmitted at the end of SERIAL port data. To define this postamble, scan up to 15 characters from the FULL ASCII chart on the reverse side of the SETUP MENU. Scan the "ON" bar code when complete. 3) BAR CODE SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the BAR CODE postamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 4) MAG SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the MAG STRIPE postamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 5) SERIAL SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the SERIAL port postamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. 6) ACTIVE TYPES Specifies the types of bar codes that use postambles. Select one of the following: A B C D
CODE 39 UPC-A UPC-E EAN-13
E EAN-8 I F I 2 of 5 J G CODABAR K H CODE 128 L X* ALL BAR CODES
36
CODE 93 MSI/PLESSEY CODE 11 ISBN