Page 19
UPC/EAN SUPPLEMENTS 0) SUPPLEMENTS DECODER ON Enable reading UPC & EAN supplements. OFF*
Disable reading UPC & EAN supplements.
1) ALLOW 2 DIGIT ON* Enable reading 2 digit supplements. above must be set ON. OFF
Disable reading 2 digit supplements.
2) ALLOW 5 DIGIT ON* Enable reading 5 digit supplements. above must be set ON. OFF
Option (0)
Option (0)
Disable reading 5 digit supplements.
3) REQUIRE SUPPLEMENTS Specifies how the reader will handle various supplements. 0)* UPC/EAN bar codes will be read with or without valid supplements. 1) UPC bar codes will not be read unless they are accompanied by a valid supplement. 2) EAN bar codes will not be read unless they are accompanied by a valid supplement. 3) Bookland EAN bar codes will not be read unless they are accompanied by a valid supplement. 4) All UPC/EAN bar codes will not be read unless they are accompanied by a valid supplement. 4) SEND SEPARATOR SPACE ON Insert a space between the standard bar code data and the supplemental data. OFF*
No separator space is inserted.
15
Page 20
INTERLEAVED 2 OF 5 0) I 2 OF 5 DECODER ON * Enable reading INTERLEAVED 2 OF 5 labels. OFF
Disable reading INTERLEAVED 2 OF 5 labels.
1) CHECK DIGIT: 0=NONE, 1=USS, 2=OPCC Specifies which type of check digit will be used with INTERLEAVED 2 of 5. 0* 1 2
NONE (no check digit required) UNIFORM SYMBOLOGY SPECIFICATION (3-1-3 MOD 10) OPTICAL PRODUCT CODE COUNCIL (2-1-2 MOD 10)
2) SEND CHECK DIGIT ON Transmit the INTERLEAVED 2 OF 5 check digit with the bar code data. OFF *
The check digit is not transmitted.
3) FIXED LENGTH ON Read only FIXED LENGTH INTERLEAVED 2 OF 5 bar code labels that match the lengths defined in options (4) & (5) below. (The SEND CHECK DIGIT option can be ON or OFF.) OFF *
Disable FIXED LENGTH mode. Read all INTERLEAVED 2 OF 5 labels without regard to length.
4) SET FIXED LENGTH #1 (02-60) Sets the first valid FIXED LENGTH for Interleaved 2 of 5. Scan a two digit value to enter the length. Valid lengths are 02 - 60 characters. By definition, the length of INTERLEAVED 2 OF 5 labels are an even number of characters. The default FIXED LENGTH is six (06) characters. 5) SET FIXED LENGTH #2 (02-60) Sets a second valid fixed LENGTH for INTERLEAVED 2 OF 5. Scan a two digit value to enter the length. The default length is set to zero (00) characters (i.e. the second FIXED LENGTH is disabled).
16
Page 21
CODABAR 0) CODABAR DECODER ON * Enable reading CODABAR labels. OFF
Disable reading CODABAR labels.
1) SEND START/STOP ON Transmit the CODABAR start/stop characters. OFF *
Do not transmit the CODABAR start/stop characters.
2) CLSI FORMATTING ON The reader will insert a blank after the 1st, 5th, and 10th characters of a 14-character CODABAR label. The label length does not include the start and stop characters. OFF *
Disable CLSI formatting.
3) CLSI CHECK DIGIT ON Enable the CLSI check digit. When this option is enabled, all fourteen digit numeric bar codes must contain a valid check digit. OFF*
Disable the CLSI check digit. Check digit verification will not be performed.
CODE 128 0) CODE 128 DECODER ON * Enable reading Code 128 labels. OFF
Disable reading Code 128 labels.
1) UCC-128 VERIFICATION ON A valid MOD 10 CHECK DIGIT is required on UCCMOD 10 bar codes. (Applies to 20-digit serial shipping container bar codes.) OFF *
UCC-MOD 10 bar codes are accepted without valid MOD 10 CHECK DIGITS.
2) SEND MOD 10 CHECK DIGIT ON * Transmit the MOD 10 CHECK DIGIT with the bar code entry. OFF
Do not transmit the MOD 10 CHECK DIGIT.
17
Page 22
CODE 93 0) CODE 93 DECODER ON * Enable reading CODE 93 labels. OFF
Disable reading CODE 93 labels.
1) CONCATENATE MODE ON Enable CONCATENATE MODE. The concatenate mode allows the reader to concatenate multiple bar codes in its buffer, then send them to the computer just like they were a single bar code. When a Code 93 label with a leading space is read, the reader emits two short beeps and buffers the data without transmission. This process continues until a Code 93 label without a leading space is read or 128 characters are buffered. A Code 93 bar code label that only contains a single or multiple dashes (minus sign) will clear the buffer. OFF *
Disable CONCATENATE MODE.
18
Page 23
MSI/PLESSEY 0) MSI/PLESSEY DECODER ON Enable reading MSI/PLESSEY labels. OFF *
Disable reading MSI/PLESSEY labels.
1) TWO CHECK DIGITS REQUIRED ON Two valid CHECK DIGITS are required for each label. The first check digit is defined by option (2) below. The second check digit is always MOD 10. OFF *
One valid CHECK DIGIT is required for each label. The CHECK DIGIT must be MOD 10.
2) FIRST CHECK DIGIT MOD 11 ON The FIRST CHECK DIGIT must be MOD 11. OFF *
The FIRST CHECK DIGIT must be MOD 10.
3) SEND FIRST CHECK DIGIT ON Transmit the FIRST CHECK DIGIT. OFF *
Do not transmit the FIRST CHECK DIGIT.
4) SEND SECOND CHECK DIGIT ON Transmit the SECOND CHECK DIGIT. OFF *
Do not transmit the SECOND CHECK DIGIT.
5) ISBN PLESSEY ON Enable reading of Modified Plessey ISBN bar codes. Only eleven digit ISBN bar codes will be read. OFF*
Do not read Modified Plessey ISBN bar codes.
19
Page 24
CODE 11 0) CODE 11 DECODER ON Enable reading CODE 11 labels. OFF *
Disable reading CODE 11 labels.
1) TWO CHECK DIGITS REQUIRED ON Two valid CHECK DIGITS are required for each label. OFF *
One valid CHECK DIGIT is required for each label.
2) SEND FIRST CHECK DIGIT ON Transmit the FIRST CHECK DIGIT. OFF *
Do not transmit the FIRST CHECK DIGIT.
3) SEND SECOND CHECK DIGIT ON Transmit the SECOND CHECK DIGIT. OFF *
Do not transmit the SECOND CHECK DIGIT.
20
Page 25
PREAMBLE 0) ENTER PREAMBLE This set of user-defined characters is transmitted at the beginning of bar code data. To define the PREAMBLE, scan up to 15 characters from the FULL ASCII chart on the reverse side of the SETUP MENU. Scan the "ON" bar code when complete. 1) PREAMBLE SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the PREAMBLE is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. The default setting is 0.0 seconds. 2) ACTIVE TYPES Specifies the types of bar codes that use preambles. Select one of the following: A CODE 39 B UPC-A C UPC-E D EAN-13
E EAN-8 I CODE 93 F I 2 of 5 J MSI/PLESSEY G CODABAR K CODE 11 H CODE 128 L ISBN X* ALL BAR CODES
POSTAMBLE 0) ENTER POSTAMBLE This set of user-defined characters is transmitted at the end of bar code data. To define the POSTAMBLE, scan up to 15 characters from the FULL ASCII chart on the reverse side of the SETUP MENU. Scan the "ON" bar code when complete. 1) POSTAMBLE SEND DELAY (0.0 - 9.9 SEC) This option specifies the amount of delay to occur after the POSTAMBLE is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. The default setting is 0.0 seconds. 3 4
CARRIAGE RETURN & LINE FEED (ASCII 13 & ASCII 10) USER DEFINED TERMINATION CHARACTER
2) ACTIVE TYPES Specifies the types of bar codes that use postambles. Select one of the following: A CODE 39 B UPC-A C UPC-E D EAN-13
E EAN-8 I CODE 93 F I 2 of 5 J MSI/PLESSEY G CODABAR K CODE 11 H CODE 128 L ISBN X* ALL BAR CODES
21
Page 26
BAR CODE EDIT This option allows editing bar codes before transmittal. 0) BAR CODE EDITING (Must be ON for any of the editing options below to be valid.) ON
Enable Bar Code Editing.
OFF *
Disable Bar Code Editing.
1) ENTER # OF LEADING CHARS TO STRIP (0-9, A-F) (Option (0) above must be ON.) Refers to the number (0-15) of bar code characters to be stripped, i.e., removed, from the beginning of the data entry. 2) ENTER # OF TRAILING CHARS TO STRIP (0-9, A-F) (Option (0) above must be ON.) Refers to the number (0-15) of bar code characters to be stripped, i.e., removed, from the end of the data entry. NOTE:
If the total number of strip characters (both Leading and Trailing) is greater than the number of characters of the bar code, no characters will be stripped.
3) ENTER BAR CODE TYPE TO EDIT (Option (0) above must be ON.) Refers to the type of bar codes for which editing can be enabled. The choices are listed below: A B C D E F
CODE 39 UPC-A UPC-E EAN-13 EAN-8 INTERLEAVED 2 of 5
G H I J K X*
CODABAR CODE 128 CODE 93 MSI/PLESSEY CODE 11 ALL BAR CODES
4) STRIP LEADING & TRAILING SPACES (Option (0) above must be ON.) ON
Any LEADING & TRAILING SPACES will be stripped from the data.
OFF *
No spaces will be stripped.
22
Page 27
TERMINATION CHARACTER The optional TERMINATION CHARACTER is transmitted at the end of the data. This option applies to bar code, mag stripe, and serial data. If a USER DEFINED TERMINATION CHARACTER is desired, select setting (4) below, then scan a single character from the FULL ASCII section of the MENU. 0 1 2* 3 4
NONE HORIZONTAL TAB (ASCII 09) CARRIAGE RETURN (ASCII 13) CARRIAGE RETURN & LINE FEED (ASCII 13 & ASCII 10) USER DEFINED TERMINATION CHARACTER
BEEP TONE This option sets the frequency (pitch) of the beep tone. Select one of the following: 0 1 2* 3
NONE LOW MEDIUM HIGH
BEEP LENGTH This option sets the length of the beep tone. following: 0 1* 2 3