SLOT READER (Badge Reader) Step 1:

Hold the CARD so that the bar code label is on the bottom and FACES the ARROW on the slot reader.

Step 2:

Insert the CARD into the opening on either side of the reader.

Step 3:

Holding the CARD flat against the bottom of the reader, SLIDE the card through the opening. You can slide the CARD bi-directionally (either left-to-right or right-to-left) and the data will output correctly to your computer. The CARD must maintain contact with the base of the reader while scanning. The front panel "POWER" light will change to RED while the card is being pulled through the SLOT READER. NOTE: The center of the bar code must be positioned 0.5" from the bottom edge of the card.

Step 4:

After a successful read the following will occur: The decoder will BEEP. The bar code data is transmitted to the computer.

Step 5:

When the front panel "POWER" light changes to GREEN, the reader is ready to scan another card. 6

Page 11

DEFAULT SETTINGS The Model 1000/1002 is shipped from the factory with the following default settings: CODE 39 CODE 39 DECODER FULL ASCII MOD 43 CHECK DIGIT SEND CHECK DIGIT CONCATENATE M ODE

UPC ON OFF OFF OFF OFF

UPC DECODER CONVERT UPC-E TO UPC-A CONVERT UPC-A TO EAN-13 SEND UPC-A NUMBER SYSTEM SEND UPC-E NUMBER SYSTEM SEND UPC-A CHECK DIGIT SEND UPC-E CHECK DIGIT

EAN EAN DECODER ZERO FILL EAN-8 TO EAN-13 SEND EAN-13 COUNTRY CODE SEND EAN-8 COUNTRY C ODE SEND EAN-13 CHECK DIGIT SEND EAN-8 CHECK DIGIT ISBN CONVERSION

UPC/EAN SUPPLEMENTS ON OFF ON ON ON ON OFF

SUPPLEMENTS DECODER ALLOW 2 DIGIT SUPPLEMENTS ALLOW 5 DIGIT SUPPLEMENTS REQUIRE SUPPLEMENTS SEND SEPARATOR S PACE

INT. 2 OF 5 I 2 OF 5 DECODER CHECK DIGIT SEND CHECK DIGIT FIXED LENGTH SET F IXED LENGTH #1 SET F IXED LENGTH #2

ON NONE OFF OFF 06 00

CODABAR DECODER SEND START/STOP CLSI FORMATTING CLSI CHECK DIGIT

ON OFF OFF OFF

CODE 93 ON OFF ON

CODE 93 DECODER CONCATENATE MODE

MSI/PLESSEY MSI/PLESSEY DECODER TWO CHECK DIGITS REQUIRED FIRST CHECK DIGIT MOD 11 SEND 1ST CHECK DIGIT SEND 2ND CHECK DIGIT ISBN PLESSEY

OFF ON ON OFF OFF

CODABAR

CODE 128 CODE 128 DECODER UCC-128 VERIFICATION SEND MOD 10 CHECK DIGIT

ON OFF OFF ON ON ON ON

ON OFF

CODE 11 OFF OFF OFF OFF OFF OFF

CODE 11 DECODER TWO CHECK DIGITS REQUIRED SEND 1ST CHECK DIGIT SEND 2ND CHECK DIGIT

7

OFF OFF OFF OFF

Page 12

PREAMBLE ENTER PREAMBLE PREAMBLE SEND DELAY ACTIVE TYPES

POSTAMBLE NONE 0.0 SEC. ALL

ENTER POSTAMBLE POSTAMBLE SEND DELAY ACTIVE

TERMINATION CHARACTER TERMINATION CHARACTER

BAR CODE EDIT CR

BAR CODE EDITING ENTER # OF LEADING STRIP CHAR'S ENTER # OF TRAILING STRIP C HAR'S ENTER BAR CODE TYPE TO EDIT STRIP LEADING & TRAILING S PACES

BEEP TONE BEEP TONE

MEDIUM

BEEP LENGTH

MEDIUM SHORT

TRANSMIT SPEED IBM AT USA ON

TRANSMIT SPEED

DIAGNOSTICS DIAGNOSTIC SELF TEST

OFF 0 0 ALL OFF

BEEP LENGTH

COMPUTER TYPE COMPUTER TYPE KEYBOARD T YPE KEYBOARD INSTALLED

NONE 0.0 SEC. ALL

FAST

OTHER OPTIONS OFF

SEND BAR CODE TYPE ID FUNCTION KEYS KEYBOARD CAPS LOCK STATUS KEYBOARD N UM LOCK S TATUS SPECIAL KEYS KEYBOARD A UTO C APS/N UM LOCK ALTERNATE KEYBOARD SCAN CODES TERMINATION CHARACTER OVERRIDE READ REVERSE IMAGE BAR CODES

8

OFF OFF ON OFF OFF ON OFF OFF OFF

Page 13

CHANGING THE DEFAULT SETTINGS You can easily change the default settings by simply scanning the bar code options located on the READER SETUP MENU. The READER SETUP MENU is a laminated sheet of bar codes supplied with this manual. The basic programming sequence is: START / CATEGORY / OPTION (0-9) / ON/OFF (or) NUMBER ONLY / EXIT Follow the instructions below to change the settings. Step 1:

Scan the START label at the top left corner of the SETUP MENU. This puts the reader into the program mode.

Step 2:

Scan one of the CATEGORY labels (i.e. Code 39, UPC, Computer Type, Transmit Speed).

Step 3:

Select the desired option by scanning one of the numeric labels (0 - 9).

Step 4:

If there is an (ON/OFF) next to the description, scan an ON label to enable or OFF label to disable the option.

EXAMPLE: To enable the MOD 43 check digit on Code 39, perform the following: 1) Scan the "CODE 39" category label. 2) Scan the option "2" label to select the "MOD 43 CHECK DIGIT" option. 3) Scan the "ON" label to enable option (2).

If there is a range of numbers next to the option, then scan one of the numeric labels (0 - 9). EXAMPLE: To select the OPCC check digit for Interleaved 2 of 5, perform the following: 1) 2) 3)

Scan the "INT. 2 OF 5" category label. Scan the "1" label to select the "CHECK DIGIT" option. Scan the "2" label to select OPCC.

9

Page 14

Step 5:

If you want to make another change within the SAME CATEGORY, you can scan another option number (i.e., return to "Step 3" above). If you want to make a change in a DIFFERENT CATEGORY you MUST scan the new CATEGORY (i.e., return to "Step 2" above and repeat the steps).

Step 6:

When you have finished making all of the changes, you can either: 1)

SCAN the EXIT (Save Changes) label to save all the changes OR

2)

SCAN the EXIT (Ignore Changes) label to exit without saving any changes. NOTE: You can reset the reader to the default setting by performing the following: 1) 2) 3)

Scan the START label. Scan the RESET ALL DEFAULTS label. Scan the EXIT (Save Changes) label.

10

Page 15

PROGRAMMING GUIDE START The START bar code places the reader into the program mode. After scanning this label, the reader will emit three short BEEPS to indicate that it is in the program mode. EXIT (SAVE CHANGES) Scan this bar code to EXIT the program mode and save all of the changes. After scanning this label, the reader will BEEP twice, then delay approximately one second, and emit three short BEEPS to indicate that it accepted the changes. EXIT (IGNORE CHANGES) Scan this bar code to EXIT the program mode and DISCARD all of the current changes. The reader will use the settings that were in effect before entering the program mode. RESET ALL DEFAULTS Scan this bar code to RESET all options to their DEFAULT settings. 0-9 BAR CODES These bar codes are scanned to select various options and enter programmable data into the reader. NOTE: ON

OFF

Scan option (9) to reset all of the options within the current CATEGORY back to their defaults.

If the OPTION has an (ON/OFF) beside the description, scan the ON bar code to turn ON the current option. If the OPTION has an (ON/OFF) beside the description, scan the OFF bar code to turn OFF the current option.

FULL ASCII CHART The FULL ASCII CHART is located on the back of the SETUP MENU. This chart contains the entire ASCII character set (128 characters). Use this chart to enter PREAMBLE and POSTAMBLE character strings, or for a USER DEFINED TERMINATION CHARACTER. ADDITIONAL NOTES: If the description beside the OPTION contains: (ON/OFF) Then scan either an ON or OFF label to set the option. (CHART) Then scan one or more characters from the Full ASCII Chart. (0-9) Scan the desired character from the 0-9 labels. (0.0-9.9) Scan two characters from the 0-9 labels to set the time from 0.0 to 9.9 seconds. 11

Page 16

* NOTE: Defaults are marked with " * ".

CODE 39 0) CODE 39 DECODER ON * Enable reading CODE 39 labels. OFF 1) FULL ASCII ON

OFF *

Disable reading CODE 39 labels. Enable the FULL ASCII EXTENSION to CODE 39. Option (0) above must be ON. A Full ASCII Chart is provided in Appendix C. Disable the FULL ASCII EXTENSION to CODE 39. This sets the reader to the standard CODE 39 mode.

2) MOD 43 CHECK DIGIT ON Enable the MOD 43 CHECK DIGIT for CODE 39. When this option is enabled, only CODE 39 labels that contain a valid check digit will be read. OFF *

Disable the MODE 43 CHECK DIGIT. verification will not be performed.

Check digit

3) SEND CHECK DIGIT ON Transmit the MOD 43 CHECK DIGIT with the bar code data. Requires option (2) above to be ON. OFF *

Do not transmit the MOD 43 CHECK DIGIT.

4) CONCATENATE MODE ON Enable CONCATENATE MODE. The concatenate mode allows the reader to accumulate multiple bar codes in its buffer, then send them to the computer just like they were a single bar code. When a Code 39 label containing a leading space is read, the reader emits two short beeps and buffers the data without transmission. This process continues until a Code 39 label without a leading space is read or 128 characters are buffered. A Code 39 bar code label that only contains a single or multiple dashes (minus sign) will clear the buffer. OFF *

Disable CONCATENATE MODE. 12

Page 17

UPC 0) UPC DECODER ON * Enable reading UPC-A and UPC-E labels. OFF

Disable reading UPC-A and UPC-E labels.

1) CONVERT UPC-E TO UPC-A ON Convert all UPC-E labels to their UPC-A equivalents before transmission. After conversion, the reader will follow the UPC-A programming options. OFF *

No UPC-E conversions will be performed.

2) CONVERT UPC-A TO EAN-13 ON Convert all UPC-A labels to an equivalent EAN-13 format by inserting a leading zero. After conversion, the reader will follow the EAN-13 programming options. OFF *

No UPC-A conversions will be performed.

3) SEND UPC-A NUMBER SYSTEM ON * Transmit the UPC-A NUMBER SYSTEM character. OFF

Do not transmit the UPC-A NUMBER SYSTEM character.

4) SEND UPC-E NUMBER SYSTEM ON * Transmit the UPC-E NUMBER SYSTEM character. OFF

Do not transmit the UPC-E NUMBER SYSTEM character.

5) SEND UPC-A CHECK DIGIT ON * Transmit the UPC-A CHECK DIGIT character. OFF

Do not transmit the UPC-A CHECK DIGIT character.

6) SEND UPC-E CHECK DIGIT ON * Transmit the UPC-E CHECK DIGIT character. OFF

Do not transmit the UPC-E CHECK DIGIT character.

13

Page 18

EAN 0) EAN DECODER ON * Enable reading EAN-8 and EAN-13 labels. OFF

Disable reading EAN-8 and EAN-13 labels.

1) ZERO FILL EAN-8 TO EAN-13 ON Add five leading zeroes to EAN-8 labels. After conversion, the reader will follow the EAN-13 programming options. OFF *

No conversion is performed.

2) SEND EAN-13 COUNTRY CODE ON * Transmit the EAN-13 COUNTRY CODE. OFF

Do not transmit the EAN-13 COUNTRY CODE.

3) SEND EAN-8 COUNTRY CODE ON * Transmit the EAN-8 COUNTRY CODE. OFF

Do not transmit the EAN-8 COUNTRY CODE.

4) SEND EAN-13 CHECK DIGIT ON * Transmit the EAN-13 CHECK DIGIT character. OFF

Do not transmit the EAN-13 CHECK DIGIT character.

5) SEND EAN-8 CHECK DIGIT ON * Transmit the EAN-8 CHECK DIGIT character. OFF

Do not transmit the EAN-8 CHECK DIGIT character.

6) ISBN CONVERSION ON Convert 13 DIGIT BOOKLAND/EAN (978 prefix) to it's corresponding 10 DIGIT ISBN number.

EXAMPLE: BAR CODE DATA = 9780806957906 ISBN OUTPUT = 0806957905 OFF *

Do not convert BOOKLAND/EAN to ISBN number.

14