Page 46
MRx20TR(STP/UTP)_BookA Page 24 Thursday, April 3, 1997 5:24 PM
Topology
Figure 13: AT-MR820TR Four Cascaded Repeaters The Four-Repeater Rule. The IEEE 802.3 standard provides general rules for 10Base-T cable length and network connections on single segments of cable or on point-to-point links with media attenuation and signal propagation delays. The basic rule applies for all networks. The maximum number of repeaters in the data path between any two nodes cannot exceed four.
BNC Terminator Switch The BNC Terminator switch is located on the rear panel to the left of the BNC connector. Use this switch to enable or disable internal termination at this end of the 10Base2 segment. If you are installing BNC-T connectors in the center of a segment, the termination switch must be disabled (OFF). The general rule is to terminate at each end of the cable segment. If the cable is connected directly into the port without a T-connector (end of segment), turn ON 24
Page 47
MRx20TR(STP/UTP)_BookA Page 25 Thursday, April 3, 1997 5:24 PM
AT-MR420TR and AT-MR820TR Installation Guide the termination switch. Figure 14 shows the location of the twoposition 50 Ω Terminator switch. The switch is either ON (the default) or OFF.
Figure 14: Terminator Switch OFF (disabled), When installing a hub at an intermediate point of a thinnet cable, a BNC-T connector must be used to connect the cable to the backbone port and the terminator switch must be disabled. See Figure 14. ON (enabled), When installing a hub at the end of the cable, if you need to remove the BNC-T connector and the terminator, the backbone port must be connected directly to the thinnet cable. The terminator switch must be enabled. This provides the 50 ohm termination that is required. ❑
Use the OFF position to disable termination if you are installing a link segment with a BNC-T connector on this port.
❑
Use the ON position to enable termination if you are installing a link segment without a BNC-T connector at this port, and if the unit is at the end of the cable. 25
Page 48
MRx20TR(STP/UTP)_BookA Page 26 Thursday, April 3, 1997 5:24 PM
Topology
Backbone Networks The most straightforward topology is a backbone network. Figure 15 show a backbone network topology with the AUI port attaching to a coaxial Ethernet cable.
Coaxial Backbone
AUI cable Ethernet Transceiver
100 Meters maximum Category 3-5 STP/UTP cable wired Pin to Pin
Figure 15: AT-MR820TR Backbone Topology In a backbone network topology, each workgroup has its own local network and the backbone is used to link the various workgroups through the bridges. The advantages of a backbone network topology are twofold: ❑
When the backbone network is operating correctly, any problem within a sub-network does not affect other subnetworks.
❑
Since faults are isolated to a single sub-network, they are easier to locate.
MDI/MDI-X Switch and Uplink Port While any RJ45 port can be used to cascade repeaters, port 4/8 has been specifically designed with an uplink (cascading) capability, by providing a Media Dependent Interface (MDI/MDI-X) switch. Cascading through port 4/8 means if a single, standalone AT-MR420TR/AT-MR820TR Micro Repeater can support 4/8 ports, when a second AT-MR420TR/AT-MR820TR Micro Repeater is uplinked (cascaded) using the port 4/8 of the first unit to any port of a 26
Page 49
MRx20TR(STP/UTP)_BookA Page 27 Thursday, April 3, 1997 5:24 PM
AT-MR420TR and AT-MR820TR Installation Guide second unit. A maximum of four repeaters (the four repeater rule) can be interconnected. The network effectively consists of 6 nodes for the AT-MR420TR and 14 nodes for the AT-MR820TR. The Uplink port is located on the back panel, as shown in Figure 16.
Figure 16: Uplink Port for MR420TR/820TR Port 4/8 has the ability to become a dedicated uplink port. To facilitate this process, it uses a Media Dependent Interface (MDI/MDI-X) switch. An MDI/MDI-X switch is a crossover/straight-through cable selection slide switch. As shown in Figure 16, the MDI/MDI-X switch converts the 10Base-T (RJ45) Port 4/ 8, to an uplinkable port that allows one repeater to connect to another repeater without requiring special crossover cables. The default setting for the RJ45 pinout switch is MDI-X (standard RJ45 port), which means the slide switch is to the right. ❑
In the default MDI-X configuration you can connect the 10Base-T port to a workstation or to any other DTE (that is, node).
27
Page 50
MRx20TR(STP/UTP)_BookA Page 28 Thursday, April 3, 1997 5:24 PM
Topology
❑
In the MDI configuration, the slide switch is to the left, you can connect the 10Base-T port to another 10Base-T internal crossover port, that is, a repeater using straight-through twisted pair cable to form an interrepeater link. See Figure 16.
If you use this port to connect repeaters to each other, the RJ45 pinout switch must be set to MDI. The MDI position is a repeater pinout which automatically swaps the TX and RX pinouts so that they do not conflict with the TX and RX ports at the other end of a straight-through cable. If you connect a straight-through cable to another repeater or DTE and the Link LEDs on the respective units are not on, change the position of the MDI/MDI-X switch to obtain continuity as indicated by active Link lights. The repeater will not be damaged if the MDI/MDI-X switch is in the wrong position. In general, if you install an RJ45 port cable, and the Link LED does not light, then simply change the position of the MDI/MDI-X slide switch and see if the Link LED lights. 10Base5 Backbone Figure 17 illustrates a single multiport 10Base-T AT-MR820TR Micro Repeater connecting to a thick Ethernet backbone using a transceiver.
Coaxial Backbone
AUI cable Ethernet Transceiver
100 Meters maximum Category 3-5 STP/UTP cable wired Pin to Pin
Figure 17: 10Base5 Backbone Topology
28
Page 51
MRx20TR(STP/UTP)_BookA Page 29 Thursday, April 3, 1997 5:24 PM
AT-MR420TR and AT-MR820TR Installation Guide
10Base2 Backbone A maximum of 30 AT-MR420TR/AT-MR820TR Micro Repeaters can be connected in a network using 10Base2 (thin Ethernet). When you use the BNC port, you avoid using transceivers to complete the linkage. See Figure 18.
Figure 18: AT-MR820TR on a Backbone Using the BNC Network Port
29
Page 52
MRx20TR(STP/UTP)_BookA Page 30 Thursday, April 3, 1997 5:24 PM
Topology
Fiber Optic Backbone By attaching a fiber optic transceiver, the AUI port can connect your network to a fiber optic (10Base-FL/FOIRL) cable backbone.
100 Meters maximum Category 3-5 UTP cable wired Pin to Pin
Fiber Optic Transceiver Fiber Optic cable
Figure 19: AT-MR820TR on a Fiber Optic Backbone The advantages of fiber optic cable are as follows: ❑ immune to electromagnetic interference
❑ spans longer distances without attenuation
❑ eliminates grounding problems
❑ secure from unauthorized taps
10Base-FOIRL. The IEEE FOIRL (fiber-optic inter-repeater link) standard limit of a fiber segment is 1 km. The fiber optic cable that connects two repeaters is limited to 1 km. 10Base-FL. The more recent IEEE 10Base-FL standard extends a fiber segment length to 2 km. This applies only to topologies in which one 10Base-FL node connects to another 10Base-FL node.
30
Page 53
MRx20TR(STP/UTP)_BookA Page 31 Thursday, April 3, 1997 5:24 PM
Appendix A
Technical Specifications
The AT-MR420TR/AT-MR820TR Specifications Physical Height
37.6 mm (1.55 in.)
Width
332 mm (13 in.)
Depth
112 mm (4.4 in.)
Installation options
Tabletop or rack-mount
Electrical Rating Input voltage
100-120 or 200-240 VAC
Frequency
50 or 60 Hz
Amperage
0.5/0.25 Amp
Connector Ports 4/8
RJ45 Ethernet ports (MDI-X)
1
AUI D-type, 15-pin female port
1
BNC female port
Environmental Operating temperature
0˚ to +40˚ C (32˚ to 104˚ F)
Relative humidity
0% to 95%, non-condensing
31
Page 54
MRx20TR(STP/UTP)_BookA Page 32 Thursday, April 3, 1997 5:24 PM
Technical Specifications
Diagnostic LEDs Individual port link status (4/8) Individual port receive activity (4/8) Hub status (3), specifying: ❑
Both Transmit and Receive activity
❑
Collision
❑
Power
Certification Safety
UL 1950, CSA 22.2 No. 950 (Canadian Standards Association), TUV EN60950
Emission
FCC Part 15 Class A, VCCI Class 1, CDOC Class A, EN55022 (CISPR 22) Class A
10Base-T Pin Assignments An Ethernet twisted-pair link segment requires two pairs of wires. Each wire pair is identified by solid and striped colored wires. For example, one wire in the pair might be red and the other wire, red with white stripes.