Page 37

MRx20TR(STP/UTP)_BookA Page 15 Thursday, April 3, 1997 5:24 PM

Chapter 3

Connectivity

Four Media Connectors This repeater has four types of ports and media connectors: ❑

AC input power connector

❑

10Base5 (AUI) network backbone port

❑

10Base2 (BNC) network backbone port

❑

Four/Eight STP/UTP 10Base-T (RJ45) ports

These four types of connecting media are described in the following sections. AC Power Connector While it is common to use dedicated power circuits or power conditioners to supply power to network devices, the source must be able to provide AC power at 100-120 VAC, 0.5A, and/or 200-240VAC, 0.25A, and 60/50 Hz (for North American models). This aids in isolating the network equipment from electrical power “noise.” The AC power connector is located on the back panel and provides connectivity for an internal power supply. It accepts 100-120 or 200-240 VAC from the rear IEC power entry port. The three-pin power receptacle, shown in Figure 8, requires a three-pin male connector.

15

Page 38

MRx20TR(STP/UTP)_BookA Page 16 Thursday, April 3, 1997 5:24 PM

Connectivity

Figure 8: Power Connector

16

Page 39

MRx20TR(STP/UTP)_BookA Page 17 Thursday, April 3, 1997 5:24 PM

AT-MR420TR and AT-MR820TR Installation Guide

10Base-T Network Specifications Table 2 provides an overview of the IEEE 802.3 specifications for 10Base-T network configurations using thick, thin, and twisted-pair wiring. Table 2: IEEE 802.3 Network Specifications 10Base-T

10Base2

10Base5

Media

Twisted Pair Cable

Thin Coaxial Cable

Thick Coaxial Cable

Topology

Star, Tree

Bus

Bus

External Devices

Network Adapter Card

Network Adapter Card

Network Adapter Card and External Transceiver

Maximum Segment Length

100 meters (328 ft.)

185 meters (605 ft.)

457 meters (1,500 ft.)

Maximum Devices per Segment

_

30

100

Maximum Devices per Network

_

1,024

1,024

AUI Port The AUI port is a 15-pin D-sub female connector, located on the back panel. This AUI backbone port connects the repeater to the network using a standard AUI drop cable. See Figure 9. Alternatively, you can fit any of a variety of Allied Telesyn’s 802.3 transceivers into this port should you select a different medium such as fiber optics.

17

Page 40

MRx20TR(STP/UTP)_BookA Page 18 Thursday, April 3, 1997 5:24 PM

Connectivity

Figure 9: AUI Network Port 10Base5 (Thick) Ethernet Cable. When configuring 10Base5 coax segments, IEEE 802.3 specifications allow a maximum of 100 MAU attachments, spaced at multiples of 2.5 meters (8.2 ft.) measured accurately from the cable end (50 Ω terminator included). The 10Base5 cable segment should not exceed 500 meters (1,640 ft.). Worst-case “end-to-end” propagation delay of a 10Base5 coax segment is 2165 ns. Propagation delay of 10Base5 Ethernet coax is calculated at 4.33 ns/ meter. Both ends of the segment must be terminated with a 50 Ω termination with a power rating of 0.5 watts or greater. Earth grounding of the segment shield is allowed at only one point on the cable. AUI Drop Cables. AUI or drop cables should not exceed 50 meters (164 ft.) each. Attachments may be made only to the cable ends at the 15-pin D-shell connector. AUI cables may have a maximum 257 ns propagation delay, as used for computing the worst-case propagation delay of a cable system. AUI cable propagation delay is approximately

18

Page 41

MRx20TR(STP/UTP)_BookA Page 19 Thursday, April 3, 1997 5:24 PM

AT-MR420TR and AT-MR820TR Installation Guide

5.13 ns/meter. This cable internally consists of four shielded twisted pair wires with an overall shield and drain wire; a 15-pin D-shell male connector at one end and a 15-pin D-shell female connector at the other end. Cable impedance is nominally 78 Ω. The AUI cable typically connects a transceiver attached to a coaxial segment to a DTE (workstation). BNC Port 10Base2 requires an RG58U, thin coaxial cable. This cable is a 10 Mbits/sec baseband with 50 Ω impedance. See Figure 10. Connected with BNC-series connectors, the maximum segment length is 185 meters (606 ft.). 10Base2 (Thin) Ethernet. When configuring thin coax segments, IEEE 802.3 specifications allow 30 or fewer MAUs per cable segment spaced at no less than 0.5 meter (1.64 ft.). The 10Base2 cable length cannot exceed 185 meters (606 ft.) per 10Base2 cable segment. The worst case propagation delay for a 185 meters (606 ft.) thin Ethernet segment is 950.9 ns. The propagation delay for 10Base2 Ethernet cable is 5.14 ns/ meter. Both ends of the segment must be terminated with a 50Ω termination with a power rating of 0.5 watts or greater. The AT-MR420TR and AT-MR820TR repeaters provide internal 50Ω terminator with a slide switch. Earth grounding of the segment shield is required at only one point on the cable.

Figure 10: BNC-T Connector

19

Page 42

MRx20TR(STP/UTP)_BookA Page 20 Thursday, April 3, 1997 5:24 PM

Connectivity

Twisted Pair (RJ45) Connector Figure 11 shows a twisted pair cable with RJ45 connectors. For a 10Base-T link between a repeater and a Medium Attachment Unit (MAU) or Network Interface Controller (NIC), the cable is wired straight through.

Figure 11: RJ45 Connector 10Base-T STP cables can be up to 100 meters (328 ft.) in length. The cable should be 22 to 26 AWG TP wire with 100Ω impedance and rated at Category 3, 4, or 5. The AT-MR420TR/AT-MR820TR Micro Repeaters use RJ45 modular connectors for 10Base-T connections. 10Base-T Cable. The AT-MR420TR/AT-MR820TR Micro Repeaters support full-length, fully repeated transmission and maximum node attachments which, for the STP/UTP link, enables transmissions to 100 meters (328 ft.). A serious problem exists concerning identification of modular cable. There are various grades of voice-quality and data-quality cables available. These can appear to be similar, but their high-speed data transmission characteristics are significantly different. Some suppliers have sold purportedly data-quality cables manufactured with voicequality cabling. If any voice-quality cabling is used in a 10Base-T network system, data movement is slow, collision-prone or non-existent. To confuse the issue, the Link indicator on the interface usually indicates a valid link.

20

Page 43

MRx20TR(STP/UTP)_BookA Page 21 Thursday, April 3, 1997 5:24 PM

AT-MR420TR and AT-MR820TR Installation Guide

10Base-T connections require Category 3, 4, or 5. In most cases, if a cable type is flat, it is typically untwisted and can cause problems. Generally, cable that is more or less round in section, gives better results. Hub to MAU Wiring. The most typical TP cable for the AT-MR420TR/ AT-MR820TR Micro Repeaters is TP Hub to TP transceiver Data Terminal Equipment (DTE). To configure your own cables, see Appendix A, “Technical Specifications.”

21

Page 44 read from a scan by OCR; it may hold reading errors

td <r MRx20TR(STP/UTP)_BookA Page 22 Thursday, April 3, 1997 5:24 PM

Page 45

MRx20TR(STP/UTP)_BookA Page 23 Thursday, April 3, 1997 5:24 PM

Chapter 4

Topology

Standalone Topology Figure 12 shows a standalone topology. Four workstations are connected directly to the repeater through the repeater’s RJ45 ports.

100 Meters TP cable wired Pin to Pin

10BaseT Tranciever

Figure 12: AT-MR420TR Standalone Topology

Cascade Topology A shared Ethernet network can be expanded by interconnecting repeaters (cascading) through the UTP ports. Figure 13 shows a cascaded topology using four repeaters which is the maximum number of micro repeaters and nodes in a single segment: four micro repeaters with ten (AT-MR420TR)/twenty-six (AT-MR820TR) ports. Its design complies with the four-repeater rule. Additional UTP ports are available if the AUI port is used for cascading. 23