Page 29

MRx20TR(STP/UTP)_BookA Page 7 Thursday, April 3, 1997 5:24 PM

Chapter 2

Installation

Site Requirements Ventilation AT-MR420TR/AT-MR820TR Micro Repeaters have grilled openings on both sides for ventilation. Although they do not require an internal fan to aid in cooling, adequate ventilation is required. Ensure that the ventilation openings located on the sides of the chassis are never blocked. Note Maximum ambient operating temperature is 104o F (40o C).

Power Be sure that the voltage and frequency is either 100-120 or 200-240 VAC and 60 or 50 Hz respectively. Since there is no external power switch, power is applied when the power cord is connected. Note For countries other than the United States and Canada: use a power cord that is rated at 6 amp, 250 VAC. Also note that this cord cannot exceed 4.6 meters (15 ft.) in length and must be made of HAR cordage with IEC fittings that are approved by the country of end use.

7

Page 30

MRx20TR(STP/UTP)_BookA Page 8 Thursday, April 3, 1997 5:24 PM

Installation

Quick Installation 1. Carefully remove the AT-MR420TR/AT-MR820TR Micro Repeaters from their packaging materials. Keep the packing materials until you have successfully installed the product. 2. Place them in a location with adequate ventilation and power receptacles. 3. Apply power by plugging in the AC cord and ensure that the POWER LED on the front panel is illuminated. 4. If you are connecting to a backbone network, prepare either the AUI or BNC cable for attachment. 5. Attach your 10Base-T STP/UTP cables, with RJ45 connectors to the 10Base-T ports. If the UPLINK port is not used for cascading, you may connect a standard 10Base-T cable to port 4/8. 6. If the AT-MR420TR/AT-MR820TR Micro Repeaters are to be connected to an external transceiver, attach a transceiver to the 15-pin AUI connector on the back panel. Ensure that the external transceiver has its Signal Quality Error (SQE)/Heartbeat Test function disabled. When power is applied to the AT-MR420TR/ AT-MR820TR Micro Repeaters, the external transceiver should also have power. Note Because of the default switch positions, you do not have to changes any switches.

8

Page 31

MRx20TR(STP/UTP)_BookA Page 9 Thursday, April 3, 1997 5:24 PM

AT-MR420TR and AT-MR820TR Installation Guide

Connections The AT-MR420TR/AT-MR820TR Micro Repeaters have the following connectors: ❑

RJ45

❑

AUI

❑

BNC

RJ45 Ports Attach an RJ45 10Base-T STP/UTP cable to port 1. The respective segment LINK OK LED located on the front panel should light when the 10Base-T network adapter card in the device on the opposite end of the STP/UTP segment is operational. If not, check that the card on the opposite end of the STP segment is operational, then ensure that the proper cable is being used. Attach a second 10Base-T STP RJ45 connector to 10Base-T network port 2. The port 2 LINK OK LED on the front panel should light, provided the 10Base-T device on the opposite end of the STP/UTP cable is operational. AUI Network Port Each AT-MR420TR/AT-MR820TR Micro Repeater has one AUI port to accommodate a 10Base5 (standard or thick Ethernet cable) connection to the network backbone using an AUI or convert the media type, for example fiber optics. BNC Network Port Each AT-MR420TR/AT-MR820TR Micro Repeater has one BNC port to accommodate a 10Base2 (cheapernet or thin Ethernet cable) connection to the network backbone.

9

Page 32

MRx20TR(STP/UTP)_BookA Page 10 Thursday, April 3, 1997 5:24 PM

Installation

LED Status Indicators The front panel indicators are grouped into the following categories: ❑

Network Load

❑

Port Status

❑

Hub Status

Network Load Indicators Eight Network Load LEDs indicating the percentage of network utilization, are located on the front panel. Figure 5 shows these LEDs.

Figure 5: Network Load Indicators Port Status Indicators Two Port Status indicators are associated with each 10Base-T (RJ45) network port. Located on the front panel of the repeater, these LEDs indicate whether the port is linked, receiving data, or both. See Figure 6.

10

Page 33

MRx20TR(STP/UTP)_BookA Page 11 Thursday, April 3, 1997 5:24 PM

AT-MR420TR and AT-MR820TR Installation Guide

Note A data packet is too fast for the human eye to distinguish on an LED, therefore the LEDs will not reflect real-time activity. The repeater artificially stretches the LED on time for easier observation.

Figure 6: Port Indicators Each RJ45 repeater port has two LEDs, LINK OK and Receive: ❑

LINK OK, No light - Indicates typically a physical connection problem. The device at the other end of the cable may be powered off, the cable may be loose or disconnected, or the cable has been wired incorrectly. Check the crossover cable., Green (Steady) - Indicates a valid link exists.

❑

Receive, Amber (Flashing) - Link is OK, port is not partitioned and there is activity on the port. Brief flashes indicate low traffic levels.

In short, port status LEDs show the functionality of the port. If the LINK OK status light is green and the Receive status is flashing amber, a signal is being received and the segment attached to the port is functional.

11

Page 34

MRx20TR(STP/UTP)_BookA Page 12 Thursday, April 3, 1997 5:24 PM

Installation

If there is no link light, there is no signal continuity. Check that the attached Data Terminal Equipment (DTE) is ON and that the proper cable is being used. If this check does not identify the problem, it may indicate that a repeater or the device connected to the port is faulty. Move the cable to the adjacent ports to further isolate the problem to the repeater or to the attached device. It may be necessary to change cables to isolate the fault to a particular cable. Hub Status Indicators Three Hub status LEDs at the far right of the front panel indicate the overall status of the repeater. Figure 7 shows the location of these indicators.

Figure 7: Hub Status LEDs

12

Page 35

MRx20TR(STP/UTP)_BookA Page 13 Thursday, April 3, 1997 5:24 PM

AT-MR420TR and AT-MR820TR Installation Guide

Table 1: Hub Status LEDs LED

Color

Description

Power green lights when AC power is applied

Collision1 amber flashes indicating an SQE or frame collisions on a segment. This may be caused by an overloaded segment, faulty cable, or loose connection.

Activity green indicates that the repeater is functional and is transmitting packets

1 Occasional collisions are normal in Ethernet networks. A constantly illuminated Collision

LED may indicate that there is a prt with excessive traffic problems. If the Collision LED is flashing steadily, and you are using an external transceiver on the AUI backbone port, make certain that the SQE/Heartbeat Test function is disabled. Repeaters do not function properly when the SQE/Heartbeat Test is active.

System Check 1. Check the LINK OK LED on the front panel for the first 10Base-T port that is connected. A steady green LED indicates continuity. A valid network connection must be made from the connected port to a host or workstation on another port. 2. After a successful connection, disconnect the active 10Base-T connector and connect it to the next successive port. Continue this process until all 10Base-T ports have been validated with good network connections. 3. Establish a connection from a device connected to port 1 to a device connected to port 2. 4. Once the connection between devices attached to ports 1 and 2 has been successfully established, remove the RJ45 connector from port 2 and connect it to each of the subsequent repeater’s 10Base-T ports, 3 through 4/8, to verify their functions. 5. If all ports test successfully, install the rest of the 10Base-T RJ45 connections and ensure that the LINK LED for each port is illuminated. Remember, the 10Base-T device on the opposite end of the STP/UTP cable must be operational. 13

Page 36

MRx20TR(STP/UTP)_BookA Page 14 Thursday, April 3, 1997 5:24 PM

Installation

Note The LINK LED validates the receive pair only. The opposite end of the STP segment is responsible for validating the transmit pair.

14