The text of a manual · part 8 of 9
CentreCOM AT-MR420TR AT-MR820TR Multiport Micro Repeaters Installation Guide: Chapter 3, pages 55 to 63
Pages 55 to 63 of 72, from CentreCOM AT-MR420TR AT-MR820TR Multiport Micro Repeaters Installation Guide
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allied Telesis AT-MR820T
Page 55
MRx20TR(STP/UTP)_BookA Page 33 Thursday, April 3, 1997 5:24 PM
AT-MR420TR and AT-MR820TR Installation Guide
Connectors Notice how the pins are numbered in Figure 20. Be sure to hold the connectors in the same orientation when connecting the wires to the pins.
8 1
8
1
Figure 20: Connector Pin Numbers Each twisted-pair link segment must have a male connector attached to both ends. According to the 10Base-T specification, pins 1 and 2 on the connector are used for transmitting data; pins 3 and 6 are used for receiving data, as shown in Table 3. The TX and the RX in Table 3 represent Transmitted Data and Ready Data, respectively. Table 3: Pin Assignments Pin
Assignment *
1
TX+
2
TX-
3
RX+
6
RX-
*The “+” and “-” signs are used to represent the polarity of the two wires that make up each wire pair.
33
Page 56
MRx20TR(STP/UTP)_BookA Page 34 Thursday, April 3, 1997 5:24 PM
Technical Specifications
Straight-through Wiring If the twisted-pair link segment is to join two ports on a switch, and only one of the ports has an internal crossover, the two pairs of wires must be straight-through, as shown in Table 4. Table 4: Straight-through RJ45 Pin Assignments Hub
Device
1 (TX+)
1 (TX+)
2 (TX-)
2 (TX-)
3 (RX+)
3 (RX+)
6 (RX-)
6 (RX-)
Crossover Wiring Two AT-MR420TR/AT-MR820TR Micro Repeaters can communicate only if the transmitter on one unit is connected to the receiver on the other unit. This reversal, or crossover function, can be implemented either in the wiring or in the device itself using the MDI/MDI-X switch. When connecting AT-MR420TR/AT-MR820TR Micro Repeaters, a crossover must be used in the wiring when using any port other than 4/8. See Table 5 for crossover pin assignments. Table 5: Crossover RJ45 Pin Assignments
34
AT-MR420TR/MR820TR
AT-MR420TR/MR820TR
1 (TX+)
3 (RX+)
2 (TX-)
6 (RX-)
3 (RX+)
1 (TX+)
6 (RX-)
2 (TX-)
Page 57
MRx20TR(STP/UTP)_BookA Page 35 Thursday, April 3, 1997 5:24 PM
AT-MR420TR and AT-MR820TR Installation Guide
5 - 4 - 3 Rule In addition to the requirements outlined in Chapter 3, Table 2, follow the “5-4-3 rule” to ensure that your configuration does not exceed the maximum 10Base-T data transmission path (the longest path through any given network). The 5-4-3 rule describes the maximum path between any two devices or nodes (PCs or other stations) on the network. There can be: ❑
Up to five segments in series
❑
Up to four repeaters or multiport hubs
❑
Up to three populated segments (that is, segments attached to two or more PCs)*
* The remaining two segments are unpopulated; these are known as inter-repeater links or IRLs. This distinction between populated and unpopulated segments is significant for coax networks only. Note This rule is completely consistent with the IEEE 802.3 specification, and is meant only to summarize the configuration specification.
35
Page 58
td <r MRx20TR(STP/UTP)_BookA Page 36 Thursday, April 3, 1997 5:24 PM
Page 59
MRx20TR(STP/UTP)_BookA Page 37 Thursday, April 3, 1997 5:24 PM
Appendix B
Glossary
10Base2 - Also called thin Ethernet, thinnet or CheaperNet, a 10 MHz baseband specification. Cable impedance is 50 Ω and maximum coaxial segment length is 185 meters (607 ft.). 10Base5 - Also called thick Ethernet, a 10 MHz baseband specification. Cable impedance is 50 Ω and maximum coaxial segment is 500 meters (1,640 ft.). The cable is commonly referred to as yellow cable. Thick Ethernet cable is typically used as a trunk or backbone path of the network. 10Base-T - IEEE 802.3 STP/UTP Ethernet. Low-cost Level 3 or better STP/ UTP wiring affords 100 meters (328 ft.) of point-to-point link segments. STP/ UTP uses RJ45 connectors and sometimes 50-pin Telco connectors to a patch panel and runs at 10 MHz. ATTACHMENT UNIT INTERFACE (AUI) - Connection between a MAU (transceiver) and a DTE (typically a workstation). Includes a 15-pin D-sub connector and sometimes a 15-conductor twisted pair cable. Maximum length is 50 meters (164 ft.). BASEBAND COAXIAL SYSTEM - A system whereby information is directly encoded and impressed on the coaxial transmission medium. At any point on the medium, only one information signal at a time can be present without disruption. BAYONET NUT COUPLE (BNC) CONNECTOR - A 10Base2 thin coax connector with push-on BNC locking lug that quickly locks into place with a half twist. BIT RATE (BR) - The rate of data throughput on the medium in bits per second. Ethernet specifies 10 million bits per second. BIT TIME - The duration of one bit symbol (1/BR). Ethernet specifies a bit time of 100 ns. CARRIER SENSE - In a LAN, an ongoing activity of a data station to detect whether another station is transmitting. CARRIER SENSE MULTIPLE ACCESS with COLLISION DETECT (CSMA/CD) - This is the access method employed by IEEE 802.3 LAN transceivers, by which multiple stations compete for use of the transmission 37
Page 60
MRx20TR(STP/UTP)_BookA Page 38 Thursday, April 3, 1997 5:24 PM
Glossary medium (coax cable) for data packet transmission. It provides for a level of error detection should that transmission be corrupted or impeded by contention for the transmission medium. COAX SEGMENT - A segment of Ethernet cable that contains MAUs. COAXIAL CABLE - A two-conductor (center conductor, shield system), concentric, constant impedance transmission line used as the trunk medium in the baseband system. COAXIAL CABLE SEGMENT - A length of coaxial cable sections and coaxial connectors, terminated at each end in its characteristic impedance. COLLISION - An unwanted condition that results from concurrent transmissions on the physical medium. COMPATIBILITY INTERFACE - The MDI coaxial cable interface and the AUI branch cable interface, the two points at which hardware compatibility is defined to allow connection of independently designed and manufactured components to the baseband transmission system. CROSSOVER - Wiring used when connecting a 10Base-T MAU to another 10Base-T MAU or a 10Base-T hub to another 10Base-T hub. For example, one 10Base-T MAU has the TD (Transmitted Data) pair on the same pins as another 10Base-T MAU. If pins were wired straight, there would be two transmitters on one pair and no receiver. As a solution, the crossover cable crosses the TD pair with the RD (Ready Data) pair, to connect the TD pins on one end to the RD pins at the other end. D-SUB CONNECTOR - The AUI cable uses 15-pin D-sub connectors. “D” refers to the shape of the connector shell. Also called miniature D, DB15, or DIX connectors. DATA COMMUNICATION EQUIPMENT (DCE) - In RS-232 specification, a module, such as a modem, for connecting a DTE to other equipment. A repeater connected to a terminal or workstation for Omega management use is wired as a DCE. DATA TERMINAL EQUIPMENT (DTE) - In RS-232 specification, a module typically at the end of a segment (i.e., uninterrupted length of Ethernet cable). The DTE could be an Ethernet workstation, repeater or bridge. DIX CONNECTOR - See D-Sub Connector HEARTBEAT - See Signal Quality Error HOUSE WIRING - House wiring is the existing wiring inside a building. This wiring generally originates from one or more wiring closets, such as a telephone room. Some older buildings may have wiring unsuitable for 10 megabit data rates. In these circumstances, it is recommended that the wiring be tested with a 10Base-T signal/wire tester.
38
Page 61
MRx20TR(STP/UTP)_BookA Page 39 Thursday, April 3, 1997 5:24 PM
AT-MR420TR and AT-MR820TR Installation Guide
HUB/REPEATER - A hub is a central signal distributor. It is used in a wiring topology consisting of several point-to-point segments originating from a central point. The term hub is often used interchangeably with the term repeater. Multiport 10Base-T, 10Base2 and fiber optic (10Base-FL, FOIRL) repeaters are considered hubs. See Repeater. HUB-to-HUB WIRING - See MAU-to-MAU Wiring HUB-to-MAU WIRING - STP/UTP cables for 10Base-T hub-to-MAU or NIC cards are wired straight-through. An RJ45 receptacle at the hub would wire pin-to-pin to the RJ45 receptacle at the MAU. IMPEDANCE - An electrical characteristic of a circuit dealing with the combination of the AC and DC resistance and the appearance of that resistance to attached circuits. JABBER LOCK-UP - The MAU’s ability to automatically inhibit the transmit data from reaching the medium if the transmit data time exceeds a specified duration. This duration is in the range of 20 ms to 150 ms. Jabber lock-up protects the medium from being overrun with data packets from a possibly defective device. JAM - This is a term used to describe the collision reinforcement signal output by the repeater to all ports. The jam signal consists of 96 bits of alternating 1s and 0s. The purpose is to extend a collision sufficiently so that all devices cease transmitting. JITTER - The shift of the data bit in respect to a standard clock cycle. Jitter is undesirable and must be minimized. LINK SEGMENT - The link segment of coaxial cable is a segment that has no MAU devices, but links together two LAN devices such as repeaters. LINK TEST - In 10Base-T Ethernet there is a link test function that validates the STP/UTP link. This consists of a pulse transmitted from point A on one pair that is validated at point B. Point B also transmits a pulse on the second pair to be validated by point A. These pulses occur during media idle states (in between packets). MAU - See Medium Attachment Unit MAU-to-MAU, HUB-to-HUB WIRING - 10Base-T MAU-to-MAU or hub-tohub wiring generally requires a cross-over cable located somewhere along the STP/UTP cable run. This may commonly occur at the punch-down block or between the RJ45 wall receptacle and the workstation. MAU/TRANSCEIVER - An Ethernet transceiver is a MAU. A 10Base-T MAU interfaces the STP/UTP media to an AUI port on a workstation, repeater, bridge or other Ethernet device. MDI/MDI-X - See Medium Dependent Interface
39
Page 62
MRx20TR(STP/UTP)_BookA Page 40 Thursday, April 3, 1997 5:24 PM
Glossary
MEDIUM ATTACHMENT UNIT (MAU) - In a LAN, a device used in a data station to couple the DTE to the transmission medium. MEDIUM DEPENDENT INTERFACE (MDI) - The mechanical and electrical interface between a hub and a transceiver (MAU). MDI-X is another version of the interface that enables hubs to connect using different pin-outs, thereby avoiding conflicts that occur when receiving and transmitting packets use the same pin-out. N-SERIES - A barrel shaped, threaded connector used on 10Base5 (thick Ethernet) coaxial cable. PATCH PANEL - A 10Base-T patch panel may be used between a punchdown block and STP/UTP workstation. The patch panel generally has a female RJ45 connector on the front for each workstation and a Telco (RJ21) connector on the back, which is wired to a punch-down block. This provides a convenient way for the installer or network manager to connect the hub 10Base-T ports into the desired building locations. POLARITY CORRECTION - Many 10Base-T STP/UTP ports have a polarity correction function. If the STP/UTP wiring has RD- and RD+ inadvertently crossed, the polarity correction function will sample the signal and electrically swap the wires. If the TD- and TD+ wires are crossed, the correction would occur at the MAU on the other end of the STP/UTP link. This occurs within a single pair and should not be confused with the crossover cable. PROPAGATION DELAY - The time it takes a signal to travel from the input of a system component to the output. Usually measured in nanoseconds. IEEE 802.3 has specific propagation delay maxima for computing propagation budgets when designing a LAN. Cable length plays a major role in propagation delay; for example, a 50-meter (164-foot) AUI cable has a maximum allowable propagation delay of 257 ns. The propagation delay of cable depends on the length and velocity factor of the cable type. There are also propagation delays associated with electronics attached to the system. PUNCH-DOWN BLOCK - The punch-down block is the wiring panel where the house wiring from the building’s offices terminates. This is where many 10Base-T hubs would be located. Wiring installers use a special punch-down tool to insert the STP/UTP wire for data and voice applications. REPEATER - A device used to extend the length, topology, or interconnectivity of the physical medium beyond that imposed by a single segment, up to the maximum allowable end-to-end trunk transmission line length. Repeaters perform the basic actions of restoring signal amplitude, waveform and timing applied to normal data and collision signals. RJ45 - This connector is a 10Base-T standard for connecting STP/UTP cabling. SIGNAL QUALITY ERROR (SQE) - Also referred to as Collision or Collision Presence. This occurs when two devices attempt to transmit at the same time, which is an illegal condition. All ATI transceivers test for SQE.
40
Page 63
MRx20TR(STP/UTP)_BookA Page 41 Thursday, April 3, 1997 5:24 PM
AT-MR420TR and AT-MR820TR Installation Guide
SQE TEST - Commonly referred to as Heartbeat, is a special 802.3 signal sent by the MAU to the DTE to test the collision detection function. Some DTE want SQE and others do not. Repeaters do not want the SQE Test. STRAIGHT-THROUGH - A type of wiring connection where the pins of one connector connect to the same pins of another connector. For example, pin 1 of one connector connects to pin 1 of another connector. THICK ETHERNET - See 10Base5 THIN ETHERNET - See 10Base2 TRUNK CABLE - The coaxial cable used to distribute signals over long distances throughout a cable system. UNSHIELDED TWISTED PAIR (UTP) - A cable used in 10Base-T wiring that consists of at least two twisted pairs of 22 to 26 AWG wire. The pairs should have at least 3 twists per foot and have an impedance of 100 Ω. Level 3, Level 4 and Level 5 UTP cables fit these criteria.
41