For the Allen-Bradley 2755-LS7
Page 56
Configuring Your Reader
5–11
• End of Read Cycle. Allows you to choose the circumstances that will end the read cycle. The read cycle is the time during which the reader will receive and process label data. When the Triggering Mode option is set in an External or Serial mode of operation, the trigger event initiates the read cycle. Note: When operating in Continuous Read or Continuous Read, 1 Output, the reader is always in the read cycle. The End of Read Cycle options are listed in the following table. Parameter
Description Can end the read cycle after a specified period of time, and if no label has been read, causes a no read message, if enabled, to be transmitted. With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout ends the read cycle.
Timeout
With External Level enabled, the read cycle does not end until the falling edge trigger occurs, and the next read cycle does not begin until the next rising edge trigger. With Continuous Read, 1 Output enabled, a timeout initiates a new read cycle and allows the same label to be read again. Ends the read cycle at the occurrence of a new trigger event, and if no label has been read, causes a no read message, if enabled, to be transmitted at the occurrence of the new trigger event.
New Trigger
With either External Edge, Serial Data, or Serial Data & Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. With External Level enabled, a falling edge trigger ends a read cycle. However, the next read cycle does not begin until the occurrence of the next rising edge trigger. Ends the read cycle after a specified period of time or at the occurrence of new trigger event, and if no label has been read, causes a no read message, if enabled, to be transmitted.
Timeout and New Trigger
With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout, or an edge or serial trigger, whichever comes first, ends the read cycle. With External Level enabled, the read cycle does not end until the occurrence of a falling edge, and the next read cycle does not begin until the next rising edge trigger.
• Timeout. Allows you to define the duration of the timeout period in 10 millisecond increments. • Serial Trigger Character. Allows you to define a single ASCII character as the host serial trigger character that initiates the read cycle. The serial trigger is considered an on-line host command and requires the same command format as all host commands (that is, to be entered within the < > brackets). Note: Serial Data or Serial Data & Edge must be enabled for Serial Trigger Character to take effect. “N/A” is displayed in the menu when all other triggering modes are enabled.
Publication 2755-6.9
Page 57
5–12
Configuring Your Reader
• External Trigger Level. Allows you to determine whether a positive or negative transition will initiate the read cycle. Note: External Level, External Edge, or Serial Data & Edge must be enabled for External Trigger Level to take effect. “N/A” is displayed in the menu when all other triggering modes are enabled. • Trigger Filter. Allows you to set a trigger bounce filter duration. • Good Decode Reads. Allows you to select the number of good reads (from 1 to 31) required per label before a good decode output. Note: Be sure to set the value within the determined scan rate for the scanning setup so that the reader is capable of scanning a label the required number of times. • Match Code Type. When enabled, allows you to enter a master label into the reader’s memory to be compared with subsequently scanned labels. The Match Code Types are listed in the table below. Selecting
Causes
Disabled no effect on reader operation.
Enabled the reader to compare labels or portions of labels with the master label.
Sequential the reader to compare labels or portions of labels for sequential numbers in ascending or descending order.
Wild Card you to enter user defined wild card characters in the master label. For example, you have a ten digit label of which only the first six digits “URGENT” need to match. You can enter URGENT**** as your master label, assuming of course that the wild card is currently defined as the default asterisk (*).
With Match Code Type enabled, a master label can be entered three ways as shown on page 5–13. Note: A triggered mode must be enabled for Match Code Type to take effect. Note: Enabling Match Code Type when Number of Labels is set to any number greater than one will cause Number of Labels to default back to one. Note: If you wish to send a pulse on a Good Read, Match Code Type must be disabled.
Publication 2755-6.9
Page 58
Configuring Your Reader
5–13
Enable Match Code Type: By menu selection, by operational command <E>, or, by serial configuration command <Kn1>.
Enable New Master Pin: By menu selection, or by serial configuration command <Kz1>.
Enter the next label scanned as the master label by operational command <G>.
Download a new master label directly into memory by operational command <)XXXX)>.
Toggle reader pin 12 to GND (pin 4) to enter next label scanned as the master label. Grounding can also be accomplished by pressing the New Master switch on the interface box.
Read in the master label.
Compare the master label with subsequent labels
• New Master Pin. Allows you to momentarily connect pin 12 to ground in order to clear any existing master label information from memory and allows the next label to be read as the new master label information. Note: Match Code and a triggered mode must be enabled for New Master Pin to take effect. • Number of Labels. Allows you to choose the number of different labels that will be read in a single trigger event. The following conditions apply. – Each label must be different to be read. – The maximum number of characters in any one label is 64. – The maximum number of characters in a single scan line is 384. – The maximum number of characters for all labels is 384, including preamble, postamble, and all spaces and commas. – All no read messages are posted at the end of the data string. – If more than one label is within the scan beam at the same time, label data may not be displayed in the order of appearance. Note: If Number of Labels is set to any number greater than one while Match Code or Continuous Read, 1 Output is enabled, Number of Labels will default back to one. • Multilabel Separator. Allows you to choose the separator character to be inserted between each label.
Publication 2755-6.9
Page 59
5–14
Configuring Your Reader
• Match Code Master. Allows you to edit an existing master or • •
•
• type in a new master label from your keyboard. You can display current master and accept entry up to 64 characters. Sequential Matching. Defines the order (ascending or descending) in which labels will be compared when Match Code Type is set to Sequential. Match Start Position. Defines the first character in the label (from left to right) that will be compared with those of the master label when Match Code Type is set to Enabled or Sequential. For example, if you set Match Start Position to 3, the first 2 characters read in the label will be ignored and only the 3rd and subsequent characters to the right will be compared, up to the number of characters specified by Match Length. Match Start Position must be set to one or greater to enable this feature. Match Length. Defines the length of the character string that will be compared with that of the master label when Match Code Type is set to Enabled or Sequential and Match Start position is set to 1 or greater. For example, If Match Length is set to 6 in a 10 character label, and Match Start Position is set for 2, only the 2nd through 7th characters (from left to right) will be compared. Wild Card Character. Allows you to define the Wild Card Character that can be used when defining a Master Label. A Master label can be entered 4 different ways.
– By typing in from the keyboard at the command line of the Operations menu under Match Code Master. – With New Master Pin enabled, toggling reader pin 12 to ground (or by momentarily pressing the New Master button on the interface box) will save the next label read as the master label. – Pressing [<G>] allows the next label read to be the master label. – Sending a serial command in the format <)XXXX)> downloads data as the master label.
Publication 2755-6.9
Page 60
Configuring Your Reader
5–15
Code Types Menu The Code Types menu, shown below, allows you to choose among five bar code types and define their parameters. Default settings are in bold type face. Options can be defined for any bar code type whether or not the bar code itself is enabled at the time. Code Types Narrow Margins Status – Disabled – Enabled
Symbology ID Status – Disabled – Enabled
Code 39 Status
Check Digit
– Enabled
– Disabled
– Disabled
– Enabled
Check Digit Output
Large Interchar Gap
Fixed Code Length
– Disabled
– Disabled
– Disabled
– Enabled
– Enabled
– Enabled
Code Length – 10 – User Definable
(1 to 31)
Codabar Status – Disabled – Enabled
Start & Stop Match
Start & Stop Output
Large Interchar Gap
– Enabled
– Enabled
– Disabled
– Disabled
Fixed Code Length
– Disabled
– Disabled
– Enabled
– Enabled
Code Length
Check Digit
Check Digit Output
– 10
– Disabled
– User
– Modulus 16
– Disabled
– NW7
– Enabled
Definable (1 to 31)
– Both
I 2 of 5 Status
Check Digit
– Disabled
– Disabled
– Enabled
– Enabled
Check Digit Output
Code Length #1 – 10
– 6
– Disabled
– User Definable
– User Definable
– Enabled
(even, 0 to 30)
Code Length #2
(even, 0 to 30)
UPC Status
EAN
Supplementals
Separator
Separator (character)
– Disabled
– Disabled
– Disabled
– Disabled
– , (comma)
– Enabled
– Enabled
– Enabled
– Enabled
– User Definable
– Required
(ASCII char.)
Code 128 Status – Disabled – Enabled
Fixed Code Length – Disabled – Enabled
Code Length – 10 – User Definable
(1 to 31)
Publication 2755-6.9
Page 61
5–16
Configuring Your Reader
Narrow Margins Allows the reader to read bar codes with quiet zones less than 10 times the narrow-bar-width. Quiet zone is a term used to describe the minimum space at the leading and trailing ends of a label. Each quiet zone can be as small as five times the narrow bar element when Narrow Margins is enabled. Symbology ID The symbology ID is a string of 3 characters prefixed to label data messages. The first character is ]. The ] symbol is used whenever the option is enabled. The second character indicates the label type. Refer to the first table below for the label types. The third character is the sum of the applicable option values per symbology used. For example, you have code 39 with no character check and data is 1234. When symbology ID is disabled, the result is 1234. When the symbology ID is enabled, the result is ]A01234. Label Type Indicator
Equals
A
Code 39
F
Codabar
I
I 2 of 5
E
UPC/EAN
C
Code 128 Code 39 Option Value
No check character.
1
Reader has checked the check character.
2
Reader has removed the check character. Codabar Option Value
Option Definition
0
No check character.
2
Reader has checked the check character.
4
Reader has removed the check character. I 2 of 5 Option Value
Option Definition
0
No check character.
1
Reader has checked the check character.
2
Reader has removed the check character. UPC/EAN Option Value
0
0
Option Definition Always zero and does not follow the AIM spec.
Code 128 Option Value
Publication 2755-6.9
Option Definition
0
Option Definition Always zero and does not follow the AIM spec.
Page 62
Configuring Your Reader
5–17
Code 39
• Status • Check Digit. Code 39 is self-checking and does not normally
• • • • require a check digit. However, for additional data integrity, a Modulus 43 check digit can be added to the bar code message. With Check Digit and an External or Serial Trigger option enabled, an invalid check digit calculation will cause a no read message to be transmitted at the end of the read cycle. Check Digit Output. When enabled, the check digit character is sent along with the label data. When disabled, label data is sent without the check digit. Large Intercharacter Gap. Allows the reader to read labels with gaps between bar code characters exceeding three times the narrow element width. Fixed Code Length. Used to increase data integrity by ensuring that only one label length will be accepted. Code Length. Allows you to specify the exact number of characters that the reader will recognize (this does not include start and stop). The reader will ignore any code not having the specified length. Note: Fixed Code Length must be enabled for Code Length to take effect.
Codabar
• Status • Start and Stop Match. Requires the Codabar start and stop • • • •
• characters (a, b, c, or d) to match before a valid read can occur. Start and Stop Output. Allows the start and stop characters to be transmitted with bar code data. Large Intercharacter Gap. Allows the reader to read labels with gaps between bar code characters exceeding three times the narrow element width. Fixed Code Length. Used to increase data integrity by ensuring that only one label length will be accepted. Code Length. Allows you to specify the exact number of characters that the reader will recognize (this does not include start and stop). The reader will ignore any code not having the specified length. Note: Fixed Code Length must be enabled for Code Length to take effect. Check Digit. Allows you to select the type of checksum system Codabar will use.
Publication 2755-6.9
Page 63
5–18
Configuring Your Reader
• Check Digit Output. When enabled, the check digit character is sent along with the label data. When disabled, label data is sent without the check digit. I 2 of 5
• Status. Because I 2 of 5 is a continuous code, it is prone to
• • •
• substitution errors. Therefore, a code length must be defined and a bar code label containing an even number of digits must be used. It is also recommended that a Modulus 10 check digit be used to ensure the best possible data integrity. Check Digit. I 2 of 5 uses a Modulus 10 check digit. Check Digit Output. When enabled, the check digit character is sent along with the label data. When disabled, label data is sent without the check digit. Code Length #1. With I 2 of 5, two code lengths can be defined. When using only one label length in an application, set Code Length #2 to 0 to ensure data integrity. If a check digit is used, it must be included in the code length count. Code Length #2. If using a second label, you may also specify a zero or any even code length from 2 to 30. If you are not using a second label, set Code Length #2 to 0 to ensure data integrity.
UPC
• Status. When enabled, the reader will read UPC version A and UPC version E only. • EAN. When EAN is enabled, the reader will read UPC version A, UPC version E, EAN 13, and EAN 8. It will also append a leading zero to UPC version A label information and transmit 13 digits. If you do not want to transmit 13 digits when reading UPC version A labels, disable EAN. Note: UPC must be enabled for EAN to take effect. • Supplementals. Allows the reader to read supplemental bar code data that has been appended to the standard UPC or EAN codes. When set to Required, the reader treats the supplemental data and the bar code label as a single label. Also, supplemental data must be found or a no read will result. When set to Enabled, the reader treats the supplemental data and the bar code label as separate labels. Note: If Supplementals is set to Enabled, Number of Labels must be set to two (for each label used) and Triggering Mode must not be set to Continuous Read, 1 Output. For example, if you are using one (UPC) label and Supplementals is Enabled, set Number of Labels to 2 (but if you are using two labels under the same conditions, set Number of Labels to 4). • Separator. Allows you to insert a character between the standard UPC or EAN code and the supplemental code.
Publication 2755-6.9
Page 64
Configuring Your Reader
5–19
• Separator (Character). Allows you to change the separator character from a comma to a new value. Code 128
• Status • Fixed Code Length. Allows you to increase data integrity by ensuring that only one label length will be accepted. • Code Length. Allows you to specify the exact number of characters that the reader will recognize. The reader will ignore any code not having the specified length. Note: Fixed Code Length must be enabled for Code Length to take effect.
Publication 2755-6.9
Page 65
5–20
Configuring Your Reader
Scanner Output Menu The Scanner Output menu, shown below, allows you to configure the reader’s output. Default settings are in bold type face. Bar code output data and no read messages are transmitted on pin 2 under conditions set principally in Bar Code Output. Relay pulses are transmitted via pins 7 and 14 (Relay-1 and Relay-2, respectively) and individually configured under conditions set in Relay-1 and Relay-2. Relay-1 and Relay-2 can allow simultaneous output under individually programmed conditions. Scanner Output Relay-1 Relay-2
Output On
Polarity
– Mismatch or No Read
– Negative
– Match
– Positive
(or Good Read) – Mismatch – No Read
Bar Code Output – Good Read – Disabled – Match
When to Output – As Soon As
Possible – End Of Read
Cycle
Pulse Width (in 10 ms incs)➀ – 50 ms – User Definable
(0 to 255)
No Read Message 7 digits – No Read
No Read Output – Enabled – Disabled
– User Definable
(ASCII char.)
– Mismatch
Beeper Status
Full Screens
Laser On/Off
– On Good
– Level 4
– Enabled
– Disabled
– On No Read
– Level 5
– Disabled
– Enabled
Beeper Volume
– Off – Level 1 – Level 2 – Level 3
Partial Output Status
Start Position – 1
– 63
– Enabled
– User Definable
– User Definable
(1 to 63) ➀
Publication 2755-6.9
Length
– Disabled
(1 to 63)
Divide the number entered on the command line by 100 for time in seconds.