For the Allen-Bradley 2755-LS7
Page 102
Chapter
7
Maintenance and Troubleshooting This chapter provides information on how to maintain and troubleshoot your readers. Items include: • cleaning the scan window • troubleshooting the readers • contacting GTS
Cleaning the Scan Window
Carefully clean the window by first removing loose particles of dirt with canned ultra filtered air. Then use an optical quality cloth moistened with an optical quality cleaning fluid for plastic lenses and wipe the window in a single direction (don’t wipe cloth back and forth across window). Do not leave streaks.
!
!
ATTENTION: Do not use abrasive materials such as disposable wipes and facial tissue. Do not use solvents like alcohol or acetone. These materials will damage the window and the finish on the reader.
ATTENTION: The reader has no serviceable parts. Be careful if you open the housing of the reader.
Publication 2755-6.9
Page 103
7–2
Maintenance and Troubleshooting
Troubleshooting the Readers
The following table provides a list of the most common operating problems, probable causes, and corrective actions. Problem
Menus do not display when configuration command is sent.
Getting unintelligible code.
Menu display but no decode rate in decode rate test (<C>).
Low decode rates during decode rate test (<C>).
Probable Cause (s) 1. Host cable defective or not wired properly. 2. Wrong configuration command (or lower case d) entered. 3. Reader configuration settings do not match host’s. 1. Host and reader baud rates or parity not matched.
1. Check cable connections and wiring.
1. Wrong label type or different label type being scanned than that enabled in firmware.
1. Check label configuration settings to be certain that they match the label type being scanned. If label type is in doubt, enable Autodiscriminate All Codes (<P> command). Also ensure that fixed length and check sums, if enabled, are set correctly. 2. Reposition label and check the decode rate (<C> command).
2. Incorrect label range or label too long to be totally covered by scan beam. 3. Poor label quality. 4. Excessive ambient light, sunlight, or strobes. 5. Object detector or another reader is interfering with reads.
1. Poor label, range, placement, etc. 1. Object detector not positioned properly. 2. End of Read Cycle not properly defined. 3.. Reader not triggered when in external mode.
Decode rate okay but not getting any output (including no reads) in triggered mode.
4. Reader not triggered when in serial mode.
5. Label misaligned or reflecting direct laser light.
Table continued on the next page.
Publication 2755-6.9
Corrective Action
2. Verify that a <D> serial command (with an upper case D) is being entered. 3. Reset reader to default and/or match host settings with reader’s. 1. Check baud rates and parity and change to match the host’s settings.
3. Try a readable label. 4. Shield the bar code and/or scan head to verify that excessive light is not the problem. 5. Remount, eliminate interference, or shielding. (Many object detectors emit pulsed infrared signals that can seriously degrade the decode rate if they shine into the reader or onto the bar code label when it is being read.) 1. Use better quality labels, place reader closer to label, etc. 1. Ensure read cycle is active during the time the label is in the scan line. 2. Ensure that the proper End of Read Cycle is defined in reader configuration. 3. Ensure trigger device is operating properly. Also do a Decode Rate Test <C>. If it reads successfully, the problem is triggering. 4. Ensure that correct serial trigger character is entered with start/stop characters (a left angle bracket < (unless redefined) and a right angle bracket >). 5. Ensure the label is not excessively skewed, tilted, or otherwise disoriented. Ensure the bar code is in the scan line when it is supposed to be. Ensure that the bar code is pitched or skewed slightly so as to avoid spicular reflection.
Page 104
Maintenance and Troubleshooting
Problem
Probable Cause (s)
Decode rate okay but getting only no read messages in triggered mode
Previous label read, but subsequent label will not read. Reader not entering read cycle in triggered mode (trigger not working) “Bad bar code” message
1. Triggering/timeout out of sync. 2. Object detector or another reader interfering with reads.
3. Window dirty or obstructed. 1. Reader configured in Continuous Read 1 Output. 2. Reader in polled mode. 1. Proper trigger levels not enabled. 2. Trigger circuit not correctly wired. 3. Object detector inoperative. 1. Poor bar code quality or incorrect label position.
Corrective Action 1. Review triggering and timing. 2. Remount, eliminate interference, or shielding. (Many object detectors emit pulsed infrared signals that can seriously degrade the decode rate if they shine into the reader or onto the bar code label when it is being read.) 3. Clean or remove obstruction. 1. Scan a label that contains different data than that of the one being read. 2. Check communications protocol. 1. Ensure that the trigger pulse and the trigger polarity settings are correct. 2. Ensure that the trigger circuit wiring meets the reader requirements. 3. Check detector range and sensitivity. Try a detector that is known to be good. 1. Reposition label or test with a label that is known to be good.
“No bar code” message
1. No label is present.
1. Scan an object with a bar code on it.
“No object” message
1. No object is present.
1. Scan an object with a bar code on it.
Technical Support Services
7–3
If you have any questions about the AtomScan+ Bar Code Reader, please consult this manual first. If you can’t find the answer, contact Rockwell Automation International Support: Rockwell International Technical Support 6680 Beta Drive Mayfield Village, Ohio 36849 Inside USA and Canada, call 1–800–289–2279. Outside USA and Canada, contact your Allen-Bradley office or call USA (216) 646–6800.
Publication 2755-6.9