The text of a manual · part 2 of 17
2-D Hand-Held Bar Code Scanners (Cat. No. 2755-HTG-4) Bar Code Programming Guide, pages 11 to 20
Pages 11 to 20 of 165
The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2755-HFC-SA1 and Allen-Bradley 2755-HFC-SP2
Page 11
1–2
Scanner Configuration
The scanner is now set to these defaults: Scanner Configuration Parameters
Default Setting
Set Default Parameters
Code on Page: 1–1
Symbologies
All Enabled
1–3
Code 39 Full ASCII
Enabled
1–6
Transmit Code 39 Check Digit
Enabled
1–6
Transmit UPC-A Check Digit
Enabled
1–7
Transmit UPC-E Check Digit
Enabled
1–7
Convert UPC-E to UPC-A
Disabled
1–7
Decode UPC / EAN Supplements
Disabled
1–8
Convert EAN-8 to EAN-13
Disabled
1–9
UPC-A Preamble
System Character
1–9
UPC-E Preamble
System Character
1–9
Code 39 Code Lengths
1-55
1–10
Codabar Code Length
2-55
1–11
Interleaved 2 of 5 Code Length
14
1–12
Prefix/Suffix
Enter
1-17
Data Transmission Format
Data As Is
1–16
Transmit No-Read Message
Disabled
1–17
Transmit LRC Checksum
Disabled
1–17
Transmit Code ID Character
Disabled
1–18
Beep After Good Decode
Enabled
1–19
Beeper Tone
High
1–19
Decode Buffering
Disabled
1–19
Pause Duration
0.0 seconds
1–20
Decode Attempt Duration
0.5 seconds
1–20
Time Delay to Power Mode
30 seconds
NO TAG
Timeout Between Decodes - Same Symbol
0.6 seconds
NO TAG
Timeout Between Decodes - Different Symbols
0.0 seconds
NO TAG
Smart Raster
Enabled
1–22
Hand-Held Options
Slab Raster
1–22
Publication 2755-6.7 Downloaded from www.Manualslib.com manuals search engine
Page 12
Scanner Configuration
1–3
Select The Symbologies You Want to Enable or Disable
Enable Code 39*
Disable Code 39
Enable UPC-A*
Disable UPC-A
Enable UPC-E*
Disable UPC-E
Publication 2755-6.7 Downloaded from www.Manualslib.com manuals search engine
Page 13
1–4
Scanner Configuration
Enable Codabar
Disable Codabar*
Enable EAN 8*
Disable EAN 8
Enable EAN 13*
Disable EAN 13
Publication 2755-6.7 Downloaded from www.Manualslib.com manuals search engine
Page 14
Scanner Configuration
1–5
Select The Symbologies You Want to Enable or Disable
Enable Interleaved 2 of 5
Disable Interleaved 2 of 5*
Enable UCC/EAN-128*
Disable UCC/EAN-128
Enable Code 128* Enable Code 128*
Disable Code 128 Note: The scanner is always enabled to read Code 128 configuration codes.
Publication 2755-6.7 Downloaded from www.Manualslib.com manuals search engine
Page 15
1–6
Scanner Configuration
Enable PDF417 *
Disable PDF417
Select Code 39 Options
Enable Code 39 Full ASCII*
Disable Code 39 Full ASCII
Enable Code 39 Check Digit*
Disable Code 39 Check Digit
Publication 2755-6.7 Downloaded from www.Manualslib.com manuals search engine
Page 16
Scanner Configuration
1–7
Transmit UPC-A / UPC-E Check Digit
Transmit UPC-A Check Digit*
Do Not Transmit UPC-A Check Digit
Transmit UPC-E Check Digit*
Do Not Transmit UPC-E Check Digit
Convert UPC-E to UPC-A
Convert UPC-E to UPC-A
Do Not Convert UPC-E to UPC-A*
Publication 2755-6.7 Downloaded from www.Manualslib.com manuals search engine
Page 17
1–8
Scanner Configuration
Decode UPC / EAN Supplements
Decode UPC / EAN Supplemental
Ignore UPC / EAN With Supplementals*
Autodiscriminate UPC / EAN with Supplementals
Convert EAN-8 to EAN-13
Convert EAN-8 to EAN-13
Disable Convert EAN-8 to EAN-13*
Publication 2755-6.7 Downloaded from www.Manualslib.com manuals search engine
Page 18
Scanner Configuration
1–9
Select UPC-A Preamble
No UPC-A Preamble
UPC-A System Character Preamble*
UPC-A System Character and Country Code Preamble
Select UPC-E Preamble
No UPC-E Preamble
UPC-E System Character Preamble*
UPC-E System Character and Country Code Preamble
Publication 2755-6.7 Downloaded from www.Manualslib.com manuals search engine
Page 19
1–10
Scanner Configuration
Select Code 39 – Code Lengths
Code 39 Any Length
Code 39 Length Within Range (Range 01-55*)
Code 39 – One Discrete Length (Range 01-55) Default is None
Code 39 – Two Discrete Lengths (Range 01-55) Default is None
Publication 2755-6.7 Downloaded from www.Manualslib.com manuals search engine
Page 20
Scanner Configuration
1–11
Select Codabar Code Lengths
Codabar Any Length
Codabar Length Within Range (Range 01-55) Default is 02 –55
Codabar – One Discrete Length (Range 01-55) Default is None
Codabar – Two Discrete Lengths (Range 01-55) Default is None
Publication 2755-6.7 Downloaded from www.Manualslib.com manuals search engine