Page 30

Connecting and Operating Scanner

2-11

The custom cable for the AdaptaScan Pass Through cable connects to the RS-232 and package detect terminals in the AdaptaScan wiring base. 25-Pin Female DB Connector

PKG DET +12VDC

Custom Cable Maximum length of 18 inches (.46 meter)

Ground No Connection

Transmit (Tx)

No Connection

No Connection Receive (Rx) Clear to Send (CTS) Ready to Send (RTS) Shield (SHD)

AdaptaScan Wiring Base

The following table provides the pinout connections for the cable (DB 25-pin female connector). Pass Through Cable Pin Number (DB25 Connector)

Function

AdaptaScan Terminal Connection

2

Receive Data Input

Tx (RS-232 Terminal Block)

3

Transmit Data Output

Rx (RS-232 Terminal Block)

4

CTS Input

RTS (RS–232 Terminal Block)

5

RTS Output

CTS (RS-232 Terminal Block)

7

Ground

GND (Package Detect Terminal Block)

9

+V 4.8 to 14.0V DC

12V (Package Detect Terminal Block)

Shield

Shield Ground

SHD (RS-232 Terminal Block) Publication 2755-6.2

Page 31

2-12

Connecting and Operating Scanner

Scanner to Enhanced Decoder Scanner Port Application Use the Scanner Emulation Synapse cable (Catalog No. 2755-HFC-SA1-01) and Gun Adapter (Catalog No. 2755-NC16, Series B) to connect the scanner cable to a scanner port on the Allen-Bradley Enhanced Decoders (2755-DS1/DD1).

Power Supply

Scanner Cable

Scanner

Scanner Emulation Synapse Cable (2755-HFC-SA1-01)

Note: The power supply should be connected last.

Gun Adapter (Catalog No. 2755-NC16 Series B)

Allen-Bradley Enhanced Decoder (2755-DS/DD)

!

ATTENTION: Use the Series B Gun Adapter (Catalog No. 2755-NC16, Series B). The Series A Gun Adapter was designed for earlier versions of the hand-held scanners (such as 2755-G2, -G3) and will not work with the new hand-held scanners.

Publication 2755-6.2

Page 32

Connecting and Operating Scanner

2-13

Scanner to Enhanced Decoder Aux Port Application Use the 25-pin RS–232 Synapse cable (Catalog No. 2755-HFC-SR2-01) to connect the scanner cable to a Aux port on the Allen-Bradley Enhanced Decoders (2755-DS1/DD1).

Scanner Cable

Power Supply

Scanner

25-pin RS-232 Synapse Cable (2755-HFC-SR2-01)

Note: The power supply should be connected last.

Null Modem

Allen-Bradley Enhanced Decoder (2755-DS1/DD1)

Publication 2755-6.2

Page 33

2-14

Connecting and Operating Scanner

Scanner to Flexible Interface (RB) Module Application Use the 25-Pin RS-232 Synapse cable (Catalog No. 2755-HFC-SR2-01) to connect the scanner cable to a port on the Flexible Interface Module (Catalog No. 2760-RB). The protocol cartridges (Catalog No. 2760-SFC1, -SFC2) support RS-232 communications.

Scanner Cable

Power Supply

Scanner

RS-232 Synapse Cable (2755-HFC-SR2-01) Note: The power supply should be connected last. SFC1, SFC2 Protocol Cartridge

To RB Module Communications Port

Flexible Interface Module

Refer to the user manual for the Flexible Interface Module for the proper configuration. Make sure the Synapse cable communications settings match the Flexible Interface Module settings for the port.

Publication 2755-6.2

Page 34

Connecting and Operating Scanner

2-15

Scanner to PLC Application Use the 25-Pin RS-232 Synapse cable (Catalog No. 2755-HFC-SR2-01) to connect the scanner cable to the channel 0 port on a PLC-5. The channel 0 port must be configured for RS-232 communications.

Power Supply

Scanner Cable

Scanner

RS-232 Synapse Cable (2755-HFC-SR2-01)

Note: The power supply should be connected last. PLC-5

To Channel 0 Port

Refer to the user manuals for the Allen-Bradley 6200 Series Programming Software to make sure the channel 0 settings match the Synapse cable settings.

Publication 2755-6.2

Page 35

2-16

Connecting and Operating Scanner

Scanner to SLC Application Use the 9-Pin RS-232 Synapse cable (Catalog No. 2755-HFC-SR3-01) to connect the scanner cable to the channel 0 port on an SLC-5/03 or 5/04. The channel 0 port must be configured for RS-232 communications.

Scanner Cable

Power Supply

Scanner

RS-232 Synapse Cable (2755-HFC-SR3-01) Note: The power supply should be connected last. SLC 5/04

To Channel 0 Port

Channel 0

Refer to the user manuals for the Allen-Bradley Advanced Programming Software (APS) to make sure the channel 0 settings match the Synapse cable settings.

Publication 2755-6.2

Page 36

Connecting and Operating Scanner

2-17

Operating the Scanner 1. Check your connections. • Is the scanner cable securely attached? • Is the scanner cable securely connected to the Synapse cable? • If a power supply is required, is there power to the power supply and is the power supply plugged into the Synapse cable? 2. Test the scanner Aim the scanner at the work surface and press the trigger. You should see the red beam on the work surface, and the red LED on the back of the scanner should be on.

3. Scan a label. Scan a bar code. Adjust the scanner position so that the scan beam is centered on the bar code and overlaps both sides. When the scanner has read a symbol: • You will hear a beep from the scanner (if symbology has been enabled, all symbologies enabled at default). • The green LED will turn on and remain on until the next scan.

Publication 2755-6.2

Page 37

2-18

Connecting and Operating Scanner

Automatic Shutoff The scanner automatically stops scanning after a bar code symbol has been read. The length of time the scanner remains on without reading a label is configurable from 0.5 to 3 seconds. You must release and press the trigger again to resume scanning.

Audible Response When scanning a bar code symbol, listen for a single short beep from the scanner. This beep indicates that the bar code has been successfully scanned. Refer to the following tables for all other responses: Beep During Normal Operation This Response

Indicates

1 Beep (short high tone)

Bar code symbol decoded. Scanner audible response must be enabled.

4 Beeps (long, low tone)

Format or transmission error detected. This error occurs if the scanner is not properly configured. All data is ignored. Verify option settings.

Beep During Configuration This Response

Indicates

1 Beep (short high tone)

Bar code symbol decoded. Scanner audible response must be enabled.

1 Beep (low / high tone)

Input error. Possible causes: Incorrect bar code scanned Cancel scanned Incorrect configuration sequence

1 Beep (high / low tone)

Bar code scanned requiring a value. Scan in the value using the configuration bar codes.

1 Beep (high / low / high / low tone)

Publication 2755-6.2

Configuration setting successfully changed.

Page 38

Connecting and Operating Scanner

2-19

Beep During Code 39 Buffering This Response

Indicates

1 Beep (high / low tone)

New Code 39 data entered into the buffer.

3 Beeps (long high tone)

Code 39 buffer is full.

1 Beep (low / high / low tone)

Buffer cleared or an attempt to transmit an empty buffer occurred.

2 Beeps (long high tone)

Error in data transmission, check cable connections.

1 Beep (low / high tone)

Transmission of buffer data successful.

Publication 2755-6.2

Page 39

2-20

Connecting and Operating Scanner

Configuring the Scanner and Cables Configure the scanner, Synapse and AdaptaScan Pass Through cables by scanning the bar codes in the Bar Code Programming Guide for Decoded Hand-Held Scanners (Publication 2755-6.5). The scanner is always enabled to read the Code 128 configuration bar codes used for configuring the scanner. Refer to:

• Scanner Configuration (Chapter 3) • Communication Setup, Cable Configuration (Chapter 4)

Publication 2755-6.2