The text of a manual · part 4 of 15
Hand-Held Decoded Bar Code Scanners (Cat. No. 2755-HDG-4) User Manual: 2 - Connecting and Operating Scanner, pages 20 to 29
Pages 20 to 29 of 115, from Hand-Held Decoded Bar Code Scanners (Cat. No. 2755-HDG-4) User Manual
The original document is the PDF (622 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2755-HDG-4
Page 20
Chapter
2
Connecting and Operating Scanner This chapter describes how to connect and test the operation of the scanner. Sections include:
• • • • • • • • •
Scanner cable Scanner Emulator Synapse cable connections RS-232 Synapse cable connections Keyboard Wedge Synapse cable connections AdaptaScan Pass Through cable connections Allen-Bradley Enhanced Decoder applications Flexible Interface Module (RB) application PLC application SLC application
Safety
!
ATTENTION: Caution - use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure.
Publication 2755-6.2
Page 21
2-2
Connecting and Operating Scanner
Overview The scanner may be connected to a variety of host devices through an interface cable. The communication parameters for the cables are configured by scanning bar codes. There are four types of cables:
• • • •
Scanner Emulator Synapse cable RS-232 Synapse cable Keyboard Wedge Synapse cable AdaptaScan Pass Through cable
Note: The AdaptaScan Pass Through cable (Catalog No. 2755-HDC-GA2-08) provides a physical link between the scanner’s output connector and a user supplied custom cable connected to an AdaptaScan Bar Code Reader’s RS-232 and power terminal blocks. All configuration bar codes are in the Bar Code Programming Guide for Decoded Hand-Held Scanners (Publication No. 2755-6.5).
Publication 2755-6.2
Page 22
Connecting and Operating Scanner
2-3
Scanner to Synapse Cable or AdaptaScan Pass Through Cable The scanner to synapse cable (Catalog No. 2755-HDC-GS1-08, -20) or AdaptaScan Pass Through cable (Catalog No. 2755-HDC-GA2-08) connect to the bottom of the scanner handle.
Slot for Tab on Collar Locking Collar
Connector
Cable Connector
To attach the cable to the scanner. 1. Pull back the locking collar from the connector. 2. Insert the cable connector into the scanner. 3. Align the tabs on the locking collar with the slots on the handle. 4. Push in and turn the locking collar counterclockwise to lock. Connector is locked when flat edge of locking collar aligns with the flat edge of the scanner handle. Remove a scanner cable from a scanner by rotating the locking collar clockwise until the cable can be pulled out of the scanner. Publication 2755-6.2
Page 23
2-4
Connecting and Operating Scanner
Scanner Cable to Synapse Cable Connection To connect the scanner cable to a Synapse cable, push the cable into the connector until you hear the connector snap in place. To remove the scanner cable, press down on the small raised bump on the connector end and remove cable.
Scanner Cable
Scanner
Press Here to Remove
Synapse Cable (2755-HFC-SR3-01 shown)
Publication 2755-6.2
Page 24
Connecting and Operating Scanner
2-5
Scanner Emulation Synapse Cable Connections Use the scanner emulation Synapse cable to provide undecoded output to a scanner input port of a bar code decoder (cable has female 9-pin DB connector). The following scanner emulation cable is available.
Catalog No. 2755-HFC-SA1-01
A separate power supply provides power to the scanner. The power supply plugs into the scanner emulation Synapse cable.
Power Supply
Scanner Cable
Scanner
Scanner Emulation Synapse Cable (2755-HFC-SA1-01) Note: The power supply should be connected last.
To Bar Code Decoder
!
ATTENTION: Do not install the scanner emulation Synapse cable with power applied to either the Synapse cable or decoder. Failure to follow this caution may result in damage to the scanner, Synapse cable, or decoder.
Publication 2755-6.2
Page 25
2-6
Connecting and Operating Scanner
RS-232 Synapse Cable Connections Use the RS-232 Synapse cable to connect the scanner to any host RS-232C input port. Two types of RS-232 Synapse cables are available:
Catalog No. 2755-HFC-SR2-01
Catalog No. 2755-HFC-SR3-01
RS-232 Synapse Cable
Output Connector
Output Signal
2755-HFC-SR2-01
Male 25-pin DB
RS-232C, Txd on Pin #3
2755-HFC-SR3-01
Female 9-pin DB
RS-232C, Txd on Pin #2
!
ATTENTION: Do not install the RS-232 Synapse cable with power applied to either the Synapse cable or host device. Failure to follow this caution may result in damage to the scanner, Synapse cable, or host device.
Publication 2755-6.2
Page 26
Connecting and Operating Scanner
2-7
Connect the scanner to an RS-232 port as shown below. A separate power supply provides power to the scanner. The power supply plugs into the RS-232 Synapse cable.
Scanner Cable
Power Supply
Scanner
RS-232 Synapse Cable (2755-HFC-SR3-01 shown) Note: The power supply should be connected last. To Host RS-232 Port
Host with RS-232 Port
Publication 2755-6.2
Page 27
2-8
Connecting and Operating Scanner
Keyboard Wedge Synapse Cable Connections Use the keyboard wedge Synapse cable to connect the scanner between a keyboard and a host device. The host device interprets the decoded scanner output the same as keyboard data. Four types of keyboard wedge Synapse cables are available:
Catalog No. 2755-HFC-SP1-01
Catalog No. 2755-HFC-SP2-01
Catalog No. 2755-HFC-SV1-01
Catalog No. 2755-HFC-SV2-01
Keyboard Wedge Synapse Cable
For Keyboard Type:
2755-HFC-SP1-01
IBM AT/XT Keyboard (5-pin DIN)
2755-HFC-SP2-01
PS/2 Keyboard (6-pin Mini-DIN)
2755-HFC-SV1-01
DEC VT220/320/420
2755-HFC-SV2-01
DEC VT520
A separate power supply plugs into the Synapse cable and provides power to the scanner. The following wedge cable applications may not require the power supply if the host provides adequate power for the scanner (depends on system configuration):
• • • •
IBM PC/AT IBM PS / 2-50, 55SX, 60, 70, 80 IBM PC/XT and compatibles IBM PS/2-30
Publication 2755-6.2
Page 28
Connecting and Operating Scanner
Power Supply (May not be required see previous page.)
Scanner Cable
2-9
Scanner
Wedge Synapse Cable (2755-HFC-SP1-01 shown) Note: The power supply should be connected last. To Host Keyboard Connector
To Keyboard
To connect the scanner cable to the keyboard wedge cable, push the cable into the connector until you hear the connector snap in place. To remove the scanner cable, press down on the small raised bump on the connector end and remove cable.
!
ATTENTION: Do not install the wedge cable or disconnect/connect the keyboard with power applied to either the wedge cable or host device. Failure to follow this caution may result in damage to the scanner, wedge interface cable, or host device.
The wedge Synapse cable connects between the keyboard and the host device. Unplug the keyboard and connect one end of the wedge cable to the host keyboard input. Connect the other end of the wedge interface cable to the keyboard. Publication 2755-6.2
Page 29
2-10
Connecting and Operating Scanner
AdaptaScan Pass Through Cable Connection The standard Pass Through cable has a 25 pin male DB connector. When connecting the cable to an AdaptaScan RS-232 terminal block, you will need to attach an unterminated cable with a female 25 pin DB connector on one end. Power for the scanner is provided by the package detect terminal block connector. Important: Power for the scanner (from Package Detect terminals) is not provided until the Reader is installed on the wiring base.
AdaptaScan Pass Through Cable
Scanner
Custom Cable (see next page)
AdaptaScan Wiring Base
!
ATTENTION: Turn off all power to the AdaptaScan wiring base before making cable connections. Failure to follow this caution could result in electrical shock and/or damage to the scanner or AdaptaScan wiring base.
Publication 2755-6.2