The text of a manual · part 9 of 27
AdaptaScan Software (Cat. No. 2755-ASN) User Manual: 4 - Getting Started, pages 66 to 74
Pages 66 to 74 of 224, from AdaptaScan Software (Cat. No. 2755-ASN) User Manual
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort 2755-SN3, Accu-Sort 2755-SN5, Allen-Bradley 2755-SN5, Accu-Sort 2755-SN8 and Allen-Bradley 2755-SN8
Page 66
Getting Started
Defining a Package
4–19
This section shows how to define a package based on the match entry definition (Match 1). 1. From the Match Table dialog, click the Package button. The Packages dialog opens.
2. Click the New button. The Packages dialog opens with the default Package Name, Package 1.
Select No-Read Package
Select Match 1
3. From the Mode list, select No-Read Package. 4. Highlight Match 1 in the Match Functions box. 5. Click OK.
Publication 2755-838
Page 67
4–20
Getting Started
The Packages dialog opens with the created package definition.
Package Definition
6. Select the Output To button. The Package Outputs dialog opens.
☞ Or double-click an available output to add it to the list of outputs.
7. From the Available Outputs: list, select Discrete Input/Output 2 and then click the Add >> button. The Output To: list shows that Discrete Input/Output 2 is assigned to the package definition.
8. Click OK to return to the Packages dialog. 9. Click OK to return to the Match Table dialog. 10. Click Save and then Close. You return to the Project 1 window.
Publication 2755-838
Page 68
Getting Started
Setting the Timer
4–21
This section configures the timer that was selected as the trigger source for decoding and scanning. 1. From the Project 1 window, click the Input/Output button. The Input & Output dialog opens.
Select Timer
☞ Or double-click on Timer to open the Timer dialog.
2. Select Timer and then click the Edit button. The Timer dialog opens with a default timer name of Timer.
Cyclic Timer On 1 Second Off 1 Second
The dialog shows that the timer is set for cyclic operation, with a specified On Time and Off Time. 3. Click OK to exit and return to the Input & Output dialog. 4. Click Save and then Close to save the timer definition. You return to the Project 1 window.
Publication 2755-838
Page 69
4–22
Getting Started
Setting the Serial Port
This section describes how to configure the Reader RS-232 port (inside wiring base). To configure the serial port: 1. From the Project 1 window, click the Serial Port button. The Serial Port dialog opens. Verify the following settings:
1. Select Terminal 2. Select 9600 Baud 3. Select 0 message length (sends all data regardless of length). 4. Select No Parity, 8 Data and 1 Stop Bit. 5. Select RS-232 Connection
2. Click Save and then Close to save the serial port configuration. You return to the Project 1 window. Note: If using the DL10 Dataliner, make sure that the DL10 configuration is set to match the Reader serial port configuration: Terminal Protocol 9600 Baud No Parity 8 Data Bits 1 Stop Bit
Publication 2755-838
Page 70
Getting Started
Configuring Message Output
4–23
This section shows how to configure the Reader to send bar code data out the RS-232 port to the Dataliner message display. 1. From the Project 1 window, click the Message button. The Message dialog opens. Make the following edits:
1. Select Enable
2. Select Timer
2. Click the New button. The Message Field dialog opens. Make the following edits:
1. Select Bar Code Reader 1 2. Select UPC–A Symbol 3. Leave blank 4. Check Match Exactly box
5. Make sure Disable is not selected
Note: If you leave the Find String blank and select Match Exactly, all characters will be matched.
Publication 2755-838
Page 71
4–24
Getting Started
3. Click the Edit button. The Message Field Edit dialog opens. Make the following edits:
1. Set length to 14 2. Leave blank 3. Enter NO–READ as the Fail string
Note: If you leave the Pass String field blank, all of the decoded bar code data is placed in the message string. You could enter a string like Good Read that would be placed in the data message whenever a UPC label is decoded. The Fail String NO-READ is placed in a message when a label is decoded that does not match the content of the Find String (see previous page). 4. Click OK to exit and return to the Message dialog. 5. Click the Format button on the Message dialog. The Message Format dialog opens. Make the following edits:
1. Enter \n as the header. 2. Enter \r as the trailer.
3. Make sure Serial Port is selected.
Note: \n = Line Feed, \r = Carriage Return 6. Click OK to exit and return to the Message dialog. 7. Click Save and then Close to save the message definition and return to the Project 1 window.
Publication 2755-838
Page 72
Getting Started
Downloading the Configuration
4–25
This section shows how to download the Bar Code Reader 1 configuration to the Reader. Verify the computer to Reader connections described on page 4–5. To download the Bar Code Reader 1 configuration: 1. Select Go On–Line from the Communications menu. The Reader will be detected and displayed in the Project window: 2. From the Project 1 window, verify that Bar Code Reader 1 is selected. 3. Set the Reader address by clicking the Device button. The Device dialog opens allowing you to change the address. The Reader is shipped with a default address of 63.
4. If you want to change the address, click Apply to send the address to the Reader. It will take a few seconds for the address download to occur. 5. Click Save and then Close. You return to the Project 1 window. 6. With the Reader configuration highlighted, click the Download button to download the configuration to the Reader. The following messages appear during the download. Resetting. Please Wait . . . Sending. Please Wait . . . When the download is complete, the messages disappear. 7. Click the Scanner button and select Triggered for the laser light control. Click Apply to send the changed setting to the Reader. 8. The Reader should now be turning the scan beam on and off at 1 second intervals.
Publication 2755-838
Page 73
4–26
Getting Started
Monitoring Reader Operation
The Monitor window shows the status of the Reader while scanning and decoding bar code labels. To use the monitor display: 1. From the Project 1 window, click the Monitor button. The Monitor dialog opens.
2. Select the LED, Metrics, Counters, and Bar Code Labels check boxes. Click the Start button to begin monitoring.
Package 1:90 Match1: 30
7003063081 7003063081 7003063081
3. Move the bar code label to various distances and positions. Observe the results. The Match counter increments each time the symbol is read. Notice that when you move the symbol out of the scan beam, the Package counter (set for no reads) increments once for every trigger. 4. Click the Close button to exit the Monitor dialog and return to the Project 1 window.
Publication 2755-838
Page 74
Getting Started
Dataliner Operation
4–27
The DL10 message display should be displaying the UPC–A symbols as they are decoded. Each symbol is preceded with a line feed (\n header) and terminated with a carriage return (\r trailer).
Publication 2755-838