Page 48

Chapter

4

- Chapter Objectives

This chapter provides step-by-step instructions on how to configure the Reader to scan and decode UPC-A symbols. This section acquaints you with basic configuration and operation of the Reader by stepping through a sample configuration. Section

Configuration Description

Page

Configuration Description

4–1

What You Need

4–2

Connecting Power

4–3

Connecting the DL10

4–3

Installing the Reader

4–5

Connecting the Configuration Cable

4–5

Running the AdaptaScan Software

4–6

Downloading Firmware

4–9

Setting Up the Communication Port

4–7

Creating a New Project

4–8

Creating a New Reader Configuration

4–8

Defining the Label Setup

4–11

Configuring the Scanner

4–13

Positioning the Reader

4–13

Focusing the Reader

4–15

Configuring the Decoder

4–16

Configuring the Discrete Outputs

4–17

Setting the Timer

4–21

Setting the Serial Port

4–22

Defining a Package

4–19

Configuring Message Output

4–23

Downloading the Configuration

4–25

Monitoring Reader Operation

4–26

Dataliner Operation

4–26

The sample configuration reads UPC-A labels. The Reader will activate outputs 1 and 2. • Output 1 energizes when a label is read. • Output 2 energizes when a no-read occurs. The monitor display shows the status of the Reader operation. An optional Dataliner DL10 display receives and displays decoded bar code data from the Reader’s RS-232 port.

Page 49

4–2

Getting Started

What You Need

Personal Computer Running Windows 95 or Windows NT

Configuration Cable (Catalog No. 2755-NC48 Series B Reader, 2755-NC43 Series A Reader)

AdaptaScan Software (Catalog No. 2755-ASN)

DL10 Communication Cable 2 Conductor Shielded Cable (Belden 8303 or Equivalent)

The sample configuration requires the following items. The Datalinert DL10 and cable are optional. The DL10 is a slave message display that displays any ASCII data that it receives from the Reader. You can use the configuration software monitor function to view decoded data if a DL10 or other display device is unavailable.

AdaptaScan Bar Code Reader (Catalog No. 2755-SN3, -SN5, -SN8)

AdaptaScan Wiring Base (Catalog No. 2755-NB40, -NB41)

9-to-25 Pin Adapter Required for Computers with 25 Pin Communication Port. (Purchase Locally)

Test Bar Code Symbols (Publication No. 2755-940) Provided with this Manual

Power Supply (Catalog No. 2755-PW46, -PW47)

Wire & Small Slotted Screwdriver For Connecting Power Supply

Dataliner (DL10 with 120V Power Cord) Optional Items

Publication 2755-838

Page 50

Getting Started

Connecting Power

4–3

Before configuring the Reader, you must connect the communications cable and provide power. Power Connections Connect the power supply to the Reader wiring base as shown below. Note: This example uses unshielded wires for power connections. Make sure you use shielded cable for the final installation as described in the AdaptaScan Bar Code Reader user manual.

120V AC Wallmount Power Supply (Catalog No. 2755-PW46) 230V AC Desktop Power Supply (Catalog No. 2755-PW47)

+ GND V+ Can_H Shield Can_L V-

Reader Wiring Base

Verify the connection by applying power to the wiring base and observing the polarity LED. The LED should be green. If the LED is red, the polarity needs to be reversed. Disconnect power from the wiring base until the Reader is installed.

Publication 2755-838

Page 51

4–4

Getting Started

Connecting the DL10 Slave

Use a two conductor shielded cable to connect the DL10 data display to the RS-232 port of the Reader. The DL10 is optional. If you don’t have a DL10, you can still view decoded data using the configuration software monitor function. Note: The data viewed on the monitor window does not necessarily correlate with the data sent out of the serial port. The monitor window displays unformatted data while the serial port data may be formatted to contain other data such as replacement strings, source ID, etc. Dataliner DL10 Message Display

Dataliner Communications Port

Connect to 120 VAC Power Source

Use Belden 8303 or equivalent Tx GND

RS-232 Port

Reader Wiring Base

Publication 2755-838

Page 52

Getting Started

Installing the Reader

4–5

Carefully position the Reader on the wiring base. You don’t need to tighten the screws for this sample application.

Screws 4 Locations Don’t Tighten Screws

Wiring Base Insulating Cover

Connecting the Configuration Cable

Use the configuration cable (Catalog No. 2755-NC48 Series B, 2755-NC43 Series A) provided with the AdaptaScan software to connect the computer’s communication port to the Reader’s configuration port. If the computer has a 25-pin connector, you need a 9-to-25 pin adapter.

Configuration Cable (Catalog No. 2755-NC48 or -NC43)

9-to-25 Pin Adapter may be required

9 Pin Male D Connector 4 Pin Female Circular Connector

Personal Computer

Configuration Port Connector

Power source required See Reader user manual (Publication No. 2755-837)

Power-up Sequence

Apply power to the Reader. On initial powerup, the Reader performs a series of self-diagnostic tests and LED tests (all LEDs flash). Refer to table page 3–6 for a description of the LED indicators. When the Module LED flashes and turns a steady or flashing green, the powerup sequence is complete. The complete powerup sequence takes a few seconds.

Publication 2755-838

Page 53

4–6

Getting Started

Running the AdaptaScan Software

If you haven’t already done so, install the AdaptaScan software. Software installation procedures are described in Chapter 1. After installing the software, the AdaptaScan OLP group icon appears in the Program Manager window. To run the AdaptaScan software: 1. From the Windows Start menu, select Programs>AdaptaScan OLP>AdaptaScan OLP. The AdaptaScan window opens.

2. All configurations occur within the AdaptaScan window. Use the dialog buttons and/or menu selections to access the AdaptaScan software operations.

Publication 2755-838

Page 54

Getting Started

Communications Setup

4–7

The Reader configuration port is set for 9600 Baud and cannot be changed. This port is set by default to communicate with the first port that is available on your computer. If your computer is using a different communication port, change the port by selecting Preferences from the View menu. To change communication port settings: 1. Select Preferences from the View menu. The Preferences dialog opens.

2. Select the communications port connected to the Reader. 3. Make sure that Configuration Port connection is selected. 4. Click OK to save changes. Note: The Reader can also be connected to a Reader through a DeviceNet network connection. A DeviceNet communications card and driver software must be installed on your computer. If you are using DeviceNet Manager Software (Catalog No. 1787-MGR) to connect to an AdaptaScan Reader in a network, refer to the user manual (Publication No. 1771-2.29). Select DeviceNet connection on the Preferences dialog when using a DeviceNet network connection.

Publication 2755-838

Page 55

4–8

Getting Started

Creating a Project

Reader configuration dialogs are accessed from the Project menu. To create a project: Select New from the Project menu or click New on the AdaptaScan window. The Project window opens with the default name of Project 1.

Creating a New Reader Configuration

To create a Reader configuration: From the Project 1 window, click the New button. An application is created with the default name Bar Code Reader 1. Applicable dialog buttons are enabled.

Publication 2755-838

Page 56

Getting Started

Downloading Firmware

4–9

If the Reader is being operated for the first time (out of the box), you must download operating firmware. The Reader is shipped with a default DeviceNet address of 63. To download operating firmware to the Reader: 1. From the Communications menu, select Go-Online. The reader will be detected (if properly connected) and displayed in the project window. Note: The Query dialog may be displayed when you go on-line (depending on your preference settings). Refer to page 2–19.

Note Address

2. From the Project window, highlight the Reader name and then click the Firmware button. The Open dialog is displayed allowing you to enter or browse to the firmware file you want to download.

Select .ini Firmware File aaaa = Version Number

SNEXaaaa.ini

Publication 2755-838