Page 23

3–10

Installation Considerations

2755-LD8 Usable Beam Length

Figure 3.9 shows the Usable Beam Length versus Distance for the LD8 scanner. The black area is a no read area. The Usable Beam Length (bottom of chart) is compared to the Reading Distance (top of chart). The Usable Beam Length is approximately 20% less than the projected beam length (10% on each end of the scan line). The reading distance is measured from the scan window to the center of the symbol. Figure 3.9 LD8 Usable Beam Length ➀ LD8 Reading Distance ➁ Inches NA Centimeters NA

5 12.7

10 25.4

15 38.1

20 50.8

25 63.5

30 76.2

35 88.9

40 101.6

45 114.3

50 127.0

Usable Beam Length

Reading Distance

= Catalog No. 2755-LD8 = No Read Area

Inches NA Centimeters NA

3.3 8.4

5.5 14.1

7.8 19.7

10.0 25.3

12.2 30.9

14.4 36.6

16.6 42.2

18.8 47.8

21.0 53.4

23.3 59.1

Usable Beam Length (Nominal) ➀ Usable Beam Length for LD8 Scanners = 0.443 x (Reading Distance + 2.5 inches) ➁ Measured from the scan window to the center of the bar code symbol.

To estimate the Usable Beam Length: • Determine the distance from the window of the scanner to the center of the bar code symbol. This is your Reading Distance. • Locate your Reading Distance on Figure 3.9. The reading distances are displayed across the top of the chart. The bottom of the chart shows the nominal Usable Beam Lengths.

Page 24

Installation Considerations

Calculating Scans/Symbol

3–11

This section explains how to calculate minimum scans per symbol for picket fence and step ladder applications.

Picket Fence Applications To calculate minimum scans per symbol for picket fence applications, use this formula: S = S = A = X = Y = Z =

A (X–Y) Z

Scans per Symbol (must be at least 5) Derated Scan Rate (nominal scan rate – 5%) Usable Beam Length at Minimum Read Distance Symbol Length (including quiet zones) Conveyor Speed

Express Usable Beam Length, Symbol Length, and Conveyor Speed in similar units. Calculations assume that the scanner and decoder are triggered for the entire time the symbol is present and the symbol has a 0° pitch. (See ”Compensating for Pitched Symbols”.) Example 1: A 40 mil case code label that is 1 inch tall and 4.75 inches long (including quiet zones) is to be read in a picket fence orientation at 125 ft/min. Space is limited so the scanner must be positioned as close as possible to the labels. Since the 2755-LD8C1 scanner cannot read a 40 mil label until the scanner is 10 inches away, let’s assume that the 2755-LD4C1 scanner can read the label. At 6 inches, the LD4C1 scanner has a usable beam length of 5.525 inches. The following calculation converts Conveyor Speed to similar units (inches). 125 feet/minute x 12 inch/feet x 1 minute/60second = 25 inch/seconds

To calculate minimum scans per symbol for this application, insert these values into the formula: A X Y Z

= = = =

200 scans/second – 5% = 190 scans/second (minimum scan rate) 5.525 inches 4.75 inches 25 inches/second

S = 190 scans/second x (5.525 inches – 4.75 inches) / (25 inches / second) S = 5.89 scans

Since S (scans per symbol) is greater than 5 and the application uses good quality labels, the 2755-LD4C1 scanner is appropriate for this application.

Page 25

3–12

Installation Considerations

Calculating Scans/Symbol

Example 2: Increasing the conveyor speed in Example 1 to 300 ft/min. decreases the number of scans per symbol to less than 3. This means the 2755-LD4C1 scanner is no longer appropriate. To increase the number of scans per symbol for picket fence applications, you can do one of the following: • select a higher speed scanner • increase the usable beam length by backing the scanner away from the bar code symbol Selecting Higher Speed Scanner The LD8C1 scanner has a scan rate of 500 scans/second. It reads 40 mil labels at a minimum distance of 10 inches. At 10 inches, the LD8C1 has a usable beam length of 5.5 inches. To calculate minimum scans per symbol, use these values: A X Y Z

= = = =

500 scans/second – 5% = 475 scans/second (minimum scan rate) 5.5 inches 4.75 inches 60 inch/second (equivalent to 300 ft/min. )

S = 475 scans/second x (5.5 inches – 4.75 inches) / (60 inches / second) S = 5.94 scans

Since S (scans per symbol) is greater than 5 and the application uses good quality labels, the 2755-LD8C1 scanner is appropriate for this application. Increasing Usable Beam Length The LD4C1 scanner at 10 inches produces a usable beam length of 8.1 inches. Minimum scans per symbol are now calculated using these values. A X Y Z

= = = =

200 scans/second – 5% = 190 scans/second (minimum scan rate) 8.1 inches 4.75 inches 60 inches/second (equivalent to 300 ft/min. )

S = 190 scans/second x (8.1 inches – 4.75 inches) / (60 inches / second) S = 10.6 scans

Because of the increased scan angle of the LD4, some picket fence applications can be performed with a higher number of reads using the lower speed scanner.

Page 26

Installation Considerations

3–13

Step Ladder Applications To calculate minimum scans per symbol for step ladder applications, use this formula: S = S = A = H= Z =

AxH Z

Scans per Symbol (must be at least 5) Derated Scan Rate (nominal scan rate – 5%) Symbol Height (length of bars of symbol) Conveyor Speed

Conveyor Speed and Symbol Height must be expressed in similar units. Calculations assume that the scanner and decoder are triggered for the entire time the symbol is present and the symbol has a 0° pitch. (See Compensating for Pitched Symbols) Example 1: A 40 mil case code label that is 1 inch tall and 4.75 inches long is to be read in step ladder orientation at 125 ft/min. Space is limited so the scanner must be positioned as close as possible to the labels. Since the 2755-LD8C1 cannot read a 40 mil label unless the scanner is 10 inches away, let’s assume the 2755-LD4C1 scanner can read the label. The usable beam must be long enough to cover the entire symbol, including quiet zones. At 6 inches, the LD4C1 scanner has a usable beam length of 5.525 inches. The calculation below converts Conveyor Speed to similar units (inches). 125 feet/minute x 12 inch/feet x 1 minute/60second = 25 inch/second

To calculate minimum scans per symbol for this step ladder application, use the following values: A = 200 scans/seconds – 5% = 190 scans/second (minimum scan rate) H = 1 inch Z = 25 inches/second S = 190 scans/second x 1 inch / (25 inches / second) S = 7.6 scans

Since S (scans per symbol) is greater than 5 and the application uses good quality labels, the 2755-LD4C1 scanner is appropriate for this step ladder application.

Page 27

3–14

Installation Considerations

Calculating Scans/Symbol

Example 2: Increasing the conveyor speed in Example 1 to 300 ft/min. decreases the minimum number of scans per symbol to approximately 3. This value is below the recommended value of 5 scans per symbol making the 2755-LD4C1 inappropriate. The label would have to be at least 1.6 inches tall to be read by an LD4C1 scanner. To increase the number of scans per symbol for step ladder applications,you can select a higher speed scanner or increase the height of the symbol. Selecting Higher Speed Scanner The LD8C1 scanner has a scan rate of 500 scans/second. It reads 40 mil labels at a minimum distance of 10 inches. To calculate the minimum number of scans per symbol use these values: A = 500 scans/second – 5% = 475 scans/second (minimum scan rate) H = 1 inch Z = 60 inches/second (equivalent to 300 ft/min. ) S = 475 scans/second x 1 inch / (60 inches / second) S = 7.9 scans

Since S (scans per symbol) is greater than 5 and the application uses good quality labels, the 2755-LD8C1 scanner is appropriate for this application. Because of the increased speed of the LD8 scanners, most high speed step ladder applications will use this scanner.

Page 28

Installation Considerations

Compensating for Pitched Symbols

3–15

You must consider the following when reading symbols that are pitched: • The apparent minimum element width • The nearest and farthest code elements must be within the scanner’s read range.

Determining Apparent Minimum Element Width When a symbol is pitched, the bars appear to be narrower and closer to one another. This apparent element width is a reduction of the actual element width. Before positioning the scanner using the read ranges in Figures 3.5 or 3.8, determine the symbol’s apparent minimum element width. Note: If the symbol has narrow spaces that are smaller than the narrow bars, base the read range on the narrow spaces. Figure 3.10 shows two boxes, each containing the same bar code symbol. Below each box is an exaggerated view of 5 elements (3 black, 2 white) as seen from the top down. Figure 3.10 Actual vs Apparent Element Width Apparent Element Width 10 mil (.25 mm) 0_ Pitch

Apparent Element Width 8.6 mil (.22 mm) 30_ Pitch Pitched 30_

Actual Element Widths 10 mils

Actual Element Widths 10 mils 30_

Apparent Element Widths 10 mils

Apparent Element Widths 8.6 mils

Page 29

3–16

Installation Considerations

Compensating for Pitched Symbols

For example, a 10 mil (0.25 mm) symbol with 0_ pitch can be scanned at 17 inches (43.2 cm) with a Catalog No. 2755-LD8C1 scanner. If you pitch the symbol 30_ and determine the apparent minimum element width using the formula below, the apparent element width is 8.6 mils (0.22 mm). Apparent Minimum Element Width = Actual Element Width x Cosine (Pitch Angle)

In the above example, the following conditions apply: Actual Element Width = 10 mil (0.25 mm) Pitch Angle = 30_ Therefore: 10 x (cos 30_) = 8.6 mil (0.22 mm)

The minimum recommended bar width that the Catalog No. 2755-LD8C1 scanner can read is 9 mil (0.23 mm). Because of the pitch of the symbol, you need to use the Catalog No. 2755-LD8B1 scanner. However, the distance between the scanner and the symbol is decreased. The maximum read range of the Catalog No. 2755-LD8B1 scanner for a 8.6 mil symbol is 13 inches (33 cm). In summary, increasing the pitch of the symbol decreases the apparent minimum element width. Figure 3.11 illustrates the above example. Figure 3.11 Effect of Pitch on Read Range Mils Millimeters

50 1.27

Apparent Minimum Element Width

45 1.14

40 1.02

35 .89

C

30 .76

25 .64

20 .51

B

15 .38

10 .25

10 mil (0.25mm) symbol with 0° pitch.

A

10 mil (0.25 mm) symbol with 30_ pitch yields apparent minimum element width of 8.6 mil (0.22 mm).

5 .13

Inches 5 Centimeters 12.7

10 25.4

15 38.1

20 50.8

25 63.5

30 76.2

Read Range (from scan window)

35 88.9

40 101.6

45 114.3

50 127.0

Page 30

Installation Considerations

3–17

Code Element Distance The nearest and farthest elements of a pitched symbol must be within the minimum and maximum reading distance of the scanner. Centering the symbol within the scanner’s read range helps to prevent pitched symbols from exceeding the read range limits. You can still exceed the read range with a pitched symbol, as shown in Figures 3.12 and 3.13. Figure 3.12 Read Range and Symbol Resolution at 0_ Pitch 18 inches (45.7 cm)

3 inch (7.6 cm) symbol is pitched 0_. The center of the symbol is 18 inches (45.7 cm) from the face of the scanner. Element width = 20 mils (.51mm) 2755–LD4B1 Symbol’s Nearest and Farthest Elements are 18 inches (45.7 cm) Mils Millimeters

50 1.27

Apparent Minimum Element Width

45 1.14

40 1.02

35 .89

C

30 .76

25 .64

The center of the 3 inch (7.6 cm) symbol is positioned 18 inches (45.7 cm) from the front of scanner.

B

20 .51

The 2755–LD4B1 scanner can be used in this application.

15 .38

10 .25

A

5 .13

Inches 5 Centimeters 12.7

10 25.4

15 38.1

20 50.8

25 63.5

30 76.2

Read Range (from scan window)

35 88.9

40 101.6

45 114.3

50 127.0

Page 31

3–18

Installation Considerations

Compensating for Pitched Symbols

Figure 3.13 further illustrates how a pitched symbol can change the read range enough to require a different scanner. Figure 3.13 Read Range and Symbol Resolution Changed By Pitch 19.5 Inches (49.5 cm) 18 Inches (45.7 cm) 3 inch (7.6 cm) symbol is pitched 30°. This requires the read range to extend an additional 1.5 inches (3.8 cm). Apparent element width = 17.3 mils (44 mm)

2755–LD4C1

Mils Millimeters

Symbol’s Nearest Elements are 18 inches (45.7 cm)

Symbol’s Farthest Elements are 19.5 inches (49.5 cm)

50 1.27

Apparent Minimum Element Width

45 1.14

40 1.02

35 .89

C

30 .76

This was the read range and element width at 0° pitch.

25 .64

B

20 .51

This is the new read range, 18 19.5 inches (45.7 - 49.5 cm). Pitching the symbol reduced the element width and extended the read range.

15 .38

10 .25

The 2755-LD4B1 scanner is not appropriate for this application. Instead use the 2755-LD4C1.

A

5 .13

Inches 5 Centimeters 12.7

10 25.4

15 38.1

20 50.8

25 63.5

30 76.2

Read Range (from scan window)

35 88.9

40 101.6

45 114.3

50 127.0