The text of a manual · part 7 of 41
AdaptaScan Bar Code Readers (Cat. Nos. 2755-SN3, -SN5, and -SN8) Application Guide: 3 - Downloading Match Codes from a Host Device, pages 49 to 56
Pages 49 to 56 of 354, from AdaptaScan Bar Code Readers (Cat. Nos. 2755-SN3, -SN5, and -SN8) Application Guide
The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort 2755-SN3, Accu-Sort 2755-SN5, Allen-Bradley 2755-SN5, Accu-Sort 2755-SN8 and Allen-Bradley 2755-SN8
Page 49
3–10
Downloading Match Codes from a Host Device
Finding Match Table Instances
When you download match codes from a host, you need the instance number of the match table. Do not assume that Match 1 = Instance 1, Match 2 = Instance 2. From the Project menu, select Print. The printout will show the class and instance numbers.
Connecting the Computer to the RS-232 Port
Disconnect the 2755-NC43 or -NC48 Configuration Cable from the personal computer. Connect the communication cable previously connected to the RS-232 connector in the wiring base to the computer’s RS-232 serial COM port.
Power source required See reader user manual
Communication Cable Connect to RS–232 Port
Personal Computer
Publication 2755-6.8
Page 50
Downloading Match Codes from a Host Device
Downloading Match Codes
3–11
To download match codes from your computer you must: 1. Convert the match string to hex. 2. Enter the match string in the proper data packet format. 3. Send the data packet (containing the string) to the reader.
Convert the Bar Code String to Hex Convert the bar code string you want to send to the reader to the hexadecimal ASCII equivalent value. For example: Bar Code String:
0
2
0
0
Converted Hex Value: 30 32 30 30 Converted Bar Code Length Value:
0
4
0
0
In the bar code length shown above, if the number of characters 04 were changed to 14, the hexadecimal value would be 0E. This hexadecimal value is written as 0E00.
Place the String in the Data Packet The bar code string is sent in a data packet having this format: 3F 10 CE 01 00 03 04 00 30 32 30 30 Instance Number
# of Characters Bar Code String in Bar Code String (in hexadecimal)
The following are descriptions of the data packet: 3F = DeviceNet Address (3F= 63, each reader has unique address) 10 = Set attribute (single request) CE = 206 = Class (always 206 for match table) 01 = Instance Number (LSB) 00 = Instance Number (MSB) 03 = Attribute Number – Rule 04 = Length of String (LSB) 00 = Length of String (MSB) 30 = ASCII “0” 32 = ASCII “2” 30 = ASCII “0” 30 = ASCII “0” Note: You can use the Windows calculator to convert decimal values to hexadecimal.
Publication 2755-6.8
Page 51
3–12
Downloading Match Codes from a Host Device
Send Data to the Reader 1. Use the Windows terminal function to send the data. Locate the terminal icon (usually within the Accessories group icon).
2. Open the terminal icon.
3. From the Settings menu open the Communications dialog and make sure that the settings match the reader serial port settings. Note: 9600 Baud must be selected.
Publication 2755-6.8
Page 52
Downloading Match Codes from a Host Device
3–13
4. From the Settings menu open the Terminal Preferences dialog and select Local Echo and Outbound (CR/LF).
5. Return to the terminal window and enter the data string to download. All characters must be in uppercase.
3F10CE010003040030323030
6. Press Return to send the data. The terminal window will display the response. 3F10CE010003040030323030 3F90
The response of 3F90 indicates a good write of the match code. 3F90 Address (3F = 63)
Response Code (90 = Successful) (94 = Fail)
Note: Refer to the next page for a description of the response code format and codes. You can verify whether or not a correct match code was downloaded by placing a bar code label in front of the reader so that it is scanned. Observe the Output #1 LED on the top of the reader. When the downloaded match code matches a scanned label, the output will turn on. If you receive a response code other than 90, refer to the the response code chart on the next page.
Publication 2755-6.8
Page 53
3–14
Downloading Match Codes from a Host Device
Response Codes Response codes have the following format: Byte
Contents
0 1 2 3
Mac ID (Address) 94 = Error Response x = General Error Code x = Additional Code
General Error Codes Code (hex) 02 08 09 0B 0C 0E 0F 10 11 13 14 15 16 18 19 D0-FF
Publication 2755-6.8
Name Resource unavailable Service not supported Invalid attribute value Already in requested mode/state Object cannot perform service in its current mode/state Attribute not settable Access permission does not allow service Device’s mode/state does not allow object to perform service Reply data too large Not enough data Attribute not supported Too much data Object does not exist No stored attribute data Store operation failure Class specific
Page 54
Downloading Match Codes from a Host Device
Downloading Other Host Commands
3–15
You can download other host commands using the same procedures described in the match code example. The following tables provide the commands and responses for the other host commands (all values are hexadecimal).
Read Performance Indicator Command
Read Performance Indicator Response
Packet Contents
Data Sent
Packet Contents
DeviceNet Address
3F*
DeviceNet Address
Response 3F
Get Performance Request
4C
Get Performance Response
CC
Class
C8
Data (LSB)
01
Instance Number (LSB)
01
Data (MSB)
00
Instance Number (MSB)
00
*3F = Address 63, modify as required
Reset Package Counter Command
Reset Package Counter Response
Packet Contents
Data Sent
Packet Contents
Response
DeviceNet Address
3F*
DeviceNet Address
3F
Set Attribute Request
10
Set Attribute Response
90
Class
D2
Instance Number (LSB)
00
Instance Number (MSB)
00
Attribute Number– Reset Counters Data
09 01
*3F = Address 63, modify as required
Read Match Counters Command
Read Match Counters Response
Packet Contents
Data Sent
Packet Contents
Response
DeviceNet Address
3F*
DeviceNet Address
3F
Get Attribute Request
0E
Get Attribute Response
8E
Class
CE
Data
6C, 08, 00, 00
Instance Number (LSB)
01
Instance Number (MSB)
00
Attribute Number
08
*3F = Address 63, modify as required
Read Package Counters Command
Read Package Counters Response
Packet Contents
Data Sent
Packet Contents
Response
DeviceNet Address
3F*
DeviceNet Address
3F
Get Attribute Request
0E
Get Attribute Response
8E
Data
6C, 08, 00, 00
Class
D2
Instance Number (LSB)
01
Instance Number (MSB)
00
Attribute Number– Match Count *3F = Address 63, modify as required
08
Publication 2755-6.8
Page 55
3–16
Downloading Match Codes from a Host Device
Reset Match Counters Command Packet Contents
Data Sent
Reset Match Counters Response Packet Contents
Response
Response Codes
3F*
DeviceNet Address
3F
Set Attribute Request
10
Set Attribute Response
90
Class
CE
Instance Number (LSB)
00
Instance Number (MSB)
00
Attribute NumberReset Counters Data
0B 01
*3F = Address 63, modify as required
Read Message Command Packet Contents
Data Sent
Read Message Response Packet Contents
Response
DeviceNet Address
3F*
DeviceNet Address
3F
Get Attribute Request
0E
Get Attribute Response
8E
Class
CC
Data (LSB)
04
Instance Number (LSB)
00
Data (MSB)
00
Instance Number (MSB)
00
ASCII Message Data
30*
Attribute Number - Message
14
ASCII Message Data
32
ASCII Message Data
30
ASCII Message Data
30
*3F = Address 63, modify as required
* Example data = 0200
Read LED Status Command
Read LED Status Response
Packet Contents
Data Sent
Packet Contents
DeviceNet Address
3F*
3F
Response 3F
Read LEDS Request
43
Read LEDS Response
C3
Class
CB
I/O 1
See Table Next Page
Instance Number (LSB)
01
I/O 2
See Table Next Page
Instance Number (MSB)
00
Trigger / Read
See Table Next Page
On Symbol
See Table Next Page
Laser On
See Table Next Page
Module
See Table Next Page
Network
See Table Next Page
*3F = Address 63, modify as required
Publication 2755-6.8
Page 56
Downloading Match Codes from a Host Device
Set Output Timer Command Packet Contents
Data Sent
Set Output Timer Response Packet Contents
Response
DeviceNet Address
3F*
DeviceNet Address
3F
Set Attribute Request
10
Set Attribute Response
90
Class
D0
Instance Number (LSB)
02
Instance Number (MSB)
00
Attribute Number - Max Time
09
Data (LSB)
FA
Data (MSB)
00
3–17
*3F = Address 63, modify as required ** Time in milliseconds
LED Status Response Data at Indicated Bit Address = LED State Byte 0
0 = Off
1 = Yellow
I/O 1
OFF
ON
3-5
I/O 2
OFF
ON
0-2
TRIGGER / READ
No Trigger
Triggered
3-5
ON SYMBOL
Not Reading
Reading
0-2
LASER ON
OFF
ON
3-5
MODULE
No Power
0-2
NETWORK
Bits
LED Indicator
0-2
1
2
3
6 = Flash Green
7 = Flash Red
Hardware Fault
Power Up
Minor Fault
DeviceNet DeviceNet OK Fault
Established
No Response
2 = Green
3 = Red
4 = Not Used
5 = Flash Yellow
Valid Read Read <100%
Device OK
3-5
Publication 2755-6.8