Page 18
Using the Auto-Load Function Overview
This application describes how to set up the AdaptaScan Bar Code Reader to use the Auto-Load function. The application uses a PHOTOSWITCHR (Catalog No. 42SRU-6203) as a package detector to trigger the decoder and a discrete input to activate the Auto-Load.
Hardware Requirements
The hardware items required for this application are: • 2755-SN3, -SN5 or -SN8 AdaptaScan Bar Code Reader • 2755-NB40 or -NB41 Wiring Base • 2755-PW46 or -PW47 Power Supply • 2755-NC43 or -NC48 Configuration Cable • PHOTOSWITCH 42SRU-6203 • 2755-IB5S DC Input Module • Computer running Windowst 3.1 (or later) or Windows 95 • 9-to-25 Pin Adapter (for computers with a 25-pin COM port)
Software Requirements
The software requirements for this application is the 2755-ASN AdaptaScan Offline Programming Software.
Related Publications
Publications you may want to refer to include: Publication
Description
2755-837
AdaptaScan Bar Code Readers User Manual
2755-838
AdaptaScan Software User Manual
Publication 2755-6.8
Page 19
1–2
Using the Auto-Load Function
Internal Power Source
The following illustration shows the wiring base connections. The 2755-IB5S DC input module and the 42SRU-6203 PHOTOSWITCH receive power from the Package Detect +12V internal power source in this application. You could also use an external AC or DC power source. Refer to the AdaptaScan Bar Code Readers User Manual (Publication No. 2755-837) for more information regarding using an external power source. 2755-IB5S External Input Contacts
To + To -
To +12V To GND
The circuit must not draw more than 50mA from the Package Detect terminal block.
Connecting a Power Supply to the Reader
The following illustration shows how to connect a 2755-PW46 or -PW47 power supply to a single bar code reader. Use a shielded cable (Belden 9316 recommended) to make the connections. Connect the shield to the ground screw on the reader’s wiring base. 2755-PW46 Power Supply
Reader 24V+
V-
Ground Screw on Wiring Base
Publication 2755-6.8
Page 20
Using the Auto-Load Function
Configuring the Reader
1–3
This section shows how to configure the AdaptaScan Reader using the AdaptaScan software (Catalog No. 2755-ASN). The procedures in this section show how to: • configure a bar code label and symbol • define a DeviceNet address • configure the scanner • configure the decoder trigger • configure the discrete input module • configure the match table, package and autoload trigger source
Create a New Project 1. Select New from the Project menu to create a new project. 2. Click the New button to add a bar code reader (Bar Code Reader 1) to the project.
3. Choose Edit from the Project menu to rename the project AutoLoad.
4. Click Save to save the project under the new name and then click Close to return to the Project dialog. Publication 2755-6.8
Page 21
1–4
Using the Auto-Load Function
Define a Bar Code Label 1. Click the Labels button to open the Bar Code Labels dialog. 2. Click the New button to add a label.
3. Click the New button to add a symbol.
4. Select the symbology and define attributes such as Identifier and Lengths. 5. Click OK until you return to the Bar Code Labels dialog. 6. Click Save to save the new label setup. 7. Click Close to return to the main Project dialog.
Publication 2755-6.8
Page 22
Using the Auto-Load Function
1–5
Define the DeviceNet Address 1. Click the Device button on the Project dialog.
2. Select a DeviceNet address. 3. Connect the 2755-NC43 or -NC48 Configuration Cable to the reader. 4. Click the Apply button to send the DeviceNet address to the reader. 5. Click Save and Close to return to the main Project dialog.
Configure the Scanner 1. Click the Scanner button on the Project dialog to open the Scanner dialog.
2. Configure the scan pattern and use the Focus procedure for optimum scanner focus. 3. Click the Close button to return to the main Project dialog.
Publication 2755-6.8
Page 23
1–6
Using the Auto-Load Function
Configure the Decoder 1. Click the Decoder button from the main Project dialog. 2. Under Triggered By, select Package Detect from the Input list.
3. Click the Save button. 4. Click the Close button and return to the main Project dialog.
Configure the Discrete Input Module The application uses a discrete input module to trigger the Auto-Load function. The following procedure defines one of the two input/output modules available in the AdaptaScan Bar Code Reader as an input. 1. Click the Input/Output button on the main Project dialog. 2. Under Inputs & Outputs, select Discrete Input/Output 2. This is the location of the 2755-IB5S DC Input Module in the reader’s wiring base. 3. Under Use As, select Input.
4. Click the Save button. 5. Click the Close button to return to the main Project dialog.
Publication 2755-6.8
Page 24
Using the Auto-Load Function
1–7
Configure the Match Table The following procedure defines the contents of the match table and the source of the symbol to be matched. 1. Click the Match Table button on the main Project dialog.
2. Click the New button to open the Match Function dialog. 3. Select the following parameters for the Match Function: • Under Function, select Auto-Load • Under Symbol Source, select Bar Code Reader 1 • Under Bar Code Labels & Symbols, select Symbol 1 under Label 1 • Check (enable) the Match Exactly check box
4. Click the OK button to return to the Match Table dialog.
Publication 2755-6.8
Page 25
1–8
Using the Auto-Load Function
Configure a Package When the application is running, the I/O 1 LED energizes (no output module is actually installed in wiring base) when a No-Match or No-Read occurs. The following procedure defines this package function. 1. From the Match Table dialog, click the Package button to open the Packages dialog.
2. Click the New button to create a package. 3. Under Mode, select No-Read or No-Match. 4. Select Match 1 under Match Functions.
5. Click OK to return to the Packages dialog.
Publication 2755-6.8
Page 26
Using the Auto-Load Function
1–9
6. Click the Output To button to open the Package Outputs dialog. 7. Under Available Outputs, select Discrete Input/Output 1. 8. Click the Add>> button to add this selection under Output To: Note: Discrete Input/Output 2 does not appear as an Available Output because it was previously defined as an input.
9. Click OK until you return to the Match Table dialog.
Configure the Auto-Load Trigger Source The application uses a discrete input module (Discrete Input/Output 2) to activate the Auto-Load function. The following procedure shows how to configure the input which will activate Auto-Load. 1. Click the AutoLoad button from the Match Table dialog. 2. Under Auto-Load Trigger: • check the Enable check box. • select Bar Code Reader 1 from the Device list. • select Discrete Input/Output 2 from the Input list.
3. Click OK to return to the Match Table dialog. 4. Click Save and then Close to return to the Project dialog.
Publication 2755-6.8
Page 27
1–10
Using the Auto-Load Function
Sending the Configuration to the Reader
From the main Project dialog, click the Send Device button to download the configuration to the bar code reader. Use the Monitor dialog to verify bar code labels as they are decoded.
Running the Application
When the application is running, bar code data is autoloaded by triggering the decoder (with Package Detect) when the desired symbol is scanned and decoded. If the bar code data is unreadable or does not match the autoloaded match string, I/O LED 1 turns on. The following illustration shows the auto-load sequence using a Package Detect as a decoder trigger. Package Detect Auto-Load Trigger remains on until Package Detect is turned off
Auto-Load Trigger Auto-Load trigger prior to Package Detect
For more information on using Auto-Load, refer to chapter 10 in the AdaptaScan Software User Manual (Publication No. 2755-838).
Publication 2755-6.8