AdaptaScan Bar Code Readers (Cat. Nos. 2755-SN3, -SN5, and -SN8) Application Guide: 15 - Downloading Match Codes via DH485 using a PLC-5 Processor and a 2760-RB Module, pages 286 to 294

Pages 286 to 294 of 354, from AdaptaScan Bar Code Readers (Cat. Nos. 2755-SN3, -SN5, and -SN8) Application Guide

The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Accu-Sort 2755-SN3, Accu-Sort 2755-SN5, Allen-Bradley 2755-SN5, Accu-Sort 2755-SN8 and Allen-Bradley 2755-SN8

Page 286

-

Downloading Match Codes via DH485 using a PLC-5 Processor and a 2760-RB Module Overview

This application describes how to download match codes to the AdaptaScan Bar Code Reader from a PLC-5 processor via DH485 protocol, using the 2760-SFC2 protocol cartridge. The application includes cable diagrams and configuration information for the AdaptaScan readers. It also includes a sample PLC-5 program which is needed to establish communication from the PLC-5 processor to the 2760-RB module.

Hardware Requirements

The hardware items required for this application are: • 2755-SN3, -SN5 or -SN8 AdaptaScan Bar Code Reader (v7.1 firmware or later) • 2755-NB40 or -NB41 Wiring Base • 2755-PW46 or -PW47 Power Supply • 2755-NC43 or -NC48 Configuration Cable • 2760-RB Interface Module • 1771 chassis • PLC-5 processor • 2760-SFC2 protocol cartridge • appropriate cables to program the PLC-5 and to configure the 2760-RB module and bar code reader. • Computer running Windows 3.1 (or later) or Windows 95 • 9-to-25 Pin Adapter (for computer with a 25-pin COM port)

Software Requirements

The software requirements for this application are: • 2755-ASN AdaptaScan Offline Programming Software • terminal emulation software to program the 2760-RB module • PLC-5 Programming Software

Related Publications

Publications you might want to refer to include: Publication

Description

2755-837

AdaptaScan Bar Code Readers User Manual

2755-838

AdaptaScan Software User Manual

2760-ND001

2760-RB Interface Module User Manual

2760-822

2760-SFC2 Protocol Cartridge User Manual

Publication 2755-6.8

Page 287

15–2

Downloading Match Codes via DH485 using a PLC-5 Processor and a 2760-RB Module

In addition, you may want to refer to the PLC-5 Hardware and Software User Manuals.

PLC-5 Compatibility

Refer to the following table for hardware compatibility in this application example. with the following PLC-5 type

Use the following 2760-RB Interface Module type

New Generation PLC-5 (Series A, Rev. C or above) Refer to the sample PLC-5 program on page 15–5. (Set BT compatibility bit S26/4 while in program mode.) Refer to the sample PLC-5 program on page 15–6. (Add ladder logic using IIN update of RB. BTR must be before BTW.)

PLC-5, -15, -25, etc.

Series A, Rev. G or below Refer to the sample PLC-5 program on page 15–5. Series A, Rev. H or above

Connecting the RB Module to the Reader

The 2760-RB configuration example includes sample configuration screens and DIP switch settings needed to establish communication with the AdaptaScan Reader via DH-485. Dip Switch Side View

Switch pushed toward top (off position).

Switch pushed toward bottom (on position).

Classic PLC-5 Processor DIP Switches Switch #

Publication 2755-6.8

Switch Lever # 1

2

3

4

5

6

7

8

SW-1 on on on on on on on off

SW-2 on on on on on on on off

SW-3 on on off off

Not Applicable

Page 288

Downloading Match Codes via DH485 using a PLC-5 Processor and a 2760-RB Module

15–3

Enhanced PLC-5 Processor DIP Switches Switch #

Switch Lever # 1

2

3

4

5

6

7

8

9

10

SW-1 on on on on on on on on on off

SW-2 on on on off off on on off on off

I/O Chassis Backplane DIP Switches Switch Lever # 1

2

3

4

5

6

7

8 off off off off off on off off

2760-RB Module DIP Switches Switch #

Switch Lever # 1

2

3

4

5

6

7

8

SW-1 off off off off off off off off

SW-2 off off off off off off off off

SW-3 off off off off

SW-4 off off on off

Not Applicable

The 2760-RB module is placed in the 1771 chassis in slot 0 next to the PLC. For this application, the AdaptaScan Reader communicates through port 1 on the 2760-RB. A 1771-ASB module can also be used to communicate with the 2760-RB module over the chassis backplane to Remote I/O. Protocol Cartridge (Catalog No. 2760-SFC2)

Flexible Interface Module (Catalog No. 2760-RB) ASCII (Dumb) Terminal DH-485 AdaptaScan Bar Code Reader

Publication 2755-6.8

Page 289

15–4

Downloading Match Codes via DH485 using a PLC-5 Processor and a 2760-RB Module

Cabling Cable 1 must be constructed to connect a configuration terminal to the 2760-RB Module Configuration port. Cable 2 must be constructed to connect the RS485 port of the bar code reader wiring base to Port 1 on the 2760-RB module. Refer to following cabling diagrams. Cable 1 2760-RB (config. port)

Dumb Terminal (VT-1000)

25-pin D male

25-pin D female

Tx 2

3 Rx

Rx 3

2 Tx

GND 7

7 GND Cable 2

2760-RB Port 1 25-pin D male

Publication 2755-6.8

AdaptaScan RS-422/485 Terminal Strip RS-485

A

TxA

B

TxB

GND 7

GND

Page 290

Downloading Match Codes via DH485 using a PLC-5 Processor and a 2760-RB Module

Configuring the PLC-5 Processor

15–5

A sample PLC program appropriate for using a PLC 5/15/25 with a 2760-RB module appears below. | I:000 N7:0 N7:5 +–––––––––––––––––––––––+ | +–––] [–––––]/[––––––]/[––––––––+Block Transfer Read +––O––+ | 13 15 15 |Rack 0| | | |Group 0| | | |Module 0| | | |Control Block N7:100+––O––+ | |Length 0| | | |Continuous N| | | +–––––––––––––––––––––––+ | | | | | | Write | | Data N7:0 N7:5 +–––––––––––––––––––––––+ | +–––] [–––––]/[––––––]/[––––––––+Block Transfer Write | | | 15 15 |Rack 0| | | |Group 0+––O––+ | |Module 0| | | |Control Block N7:5| | | |Data File N7:200+––O––| | |Length 0| | | |Continuous N| | | +–––––––––––––––––––––––+ | | |

Refer to your PLC-5 Instruction Reference Manual for detailed information on using the PLC-5 programming software.

Publication 2755-6.8

Page 291

15–6

Downloading Match Codes via DH485 using a PLC-5 Processor and a 2760-RB Module

Using the 2760-RB Module, Revision H or Above, with the New Generation PLC-5 Processor When the 2760-RB, revision H or above, is used with the new generation PLC-5 processors in a local chassis, there is a possibility that the PLC will not see the BRR bit from the 2760-RB. For the PLC-5 to see the BTR bit, an odd number of image scans must occur. To ensure that the BTR instruction sees the BRR bit (bit 13) you must place an Immediate Input Instruction addressed to the BRR bit in another rung just before the Block Transfer Read (BTR) rung. This ensures that the BRR bit is seen by the NP-5 processor. | BRR BT7:5 BT7:25 000 | +–––]/[–––––]/[––––––]/[–––––––––––––––( IIN )––––––––––––––––+ | | | BTR | | BRR BT7:5 BT7:25 +––––––––––––––––––––––+ | +–––] [–––––]/[––––––]/[–––––––––+Rack 0| | | EN EN |Group 0| | | |Module 0+––O––+ | |Control Block BT7:5| | | |Data File N7:200| | | |Length 0+––O––+ | |Continuous N| | | +––––––––––––––––––––––+ | | | | | | Write BTW | | Data BT7:5 BT7:25 +––––––––––––––––––––––+ | +–––] [–––––]/[––––––]/[–––––––––+Rack 0| | | EN EN |Group 0| | | |Module 0+––O––+ | |Control Block BT7:25| | | |Data File N7:400| | | |Length 0+––O––+ | |Continuous N| | | +––––––––––––––––––––––+ | | | | | | | | |

Note: BTR must come before BTW. Refer to your PLC-5 user manual for detailed information on using the PLC-5 programming software.

Configuring the 2760-RB Interface Module

The configuration screens for the 2760-RB should be entered exactly as shown. These parameters then need to be saved. Both the bar code reader and the 2760-RB module are configured to send and recognize the Carriage Return [Cr], Line Feed [Lf] characters to identify a message. When the 2760–RB senses information entering Port 1, it will look for the Cr, Lf. When it sees these trailers, it will Block transfer read (BTR) the preceding bar code data into the PLC program.

Publication 2755-6.8

Page 292

Downloading Match Codes via DH485 using a PLC-5 Processor and a 2760-RB Module

15–7

To configure the 2760-RB module: 1. Set all 2760-RB module DIP switches to Off. 2. Connect the smart cable to the Configuration port of the 2760-RB module and the serial port of the computer. 3. Send a “break sequence” to the 2760-RB module via the Terminal Emulator: G. Set the baud rate to 9600, 8 data bits, 1 stop bit, no parity, no flow control, and either COM1 or COM2 depending on the smart cable connection. H. Program a function key to send the “break sequence” by using the Ctrl-Shift-Break command. (This step is specifically for Windows 3.1 Terminal Emulation.) I. Send the break sequence to call up the 2760-RB module configuration menu. 4. Select menu item 3: Device port protocol names. Set to: PORT1=COPYRIGHT 1989 ALLEN-BRADLEY COMPANY INC. 2760-SFC2 LAN SERIES A REVISION B (YES/NO)=YES

5. Select menu item 21: Identification numbers. Select: RS485 LAN 2755-DM6 ASCII MODE 0H (YES/NO)=YES 6. Select option 11: Configuration parameters. Set to: SLOT TIME (NO. CHARS) (DEC 0 ... 255) = 15 INTER-CHAR TIME (NO. CHARS) (DEC 0 ... 255) = 7 IDLE TIME (NO. CHARS) (DEC 0 ... 255) = 3 RETRIES (DEC 0 ... 255) = 3 19,200 BITS PER SECOND (YES/NO)=YES BCD NODE NUMBERS (ENABLE/DISABLE)= ENABLE BYTE SWAPPING (ENABLE/DISABLE)=ENABLE RECEIVE MATRIXING (ENABLE/DISABLE)=DISABLE MATRIX ADDRESS (HEX 0 ... FFFF) = 0 RE-ESTABLISH FREQUENCY (DEC 0 ... 255)=5 POLL FREQUENCY/DESTINATION [0] (HEX 0 ... FFFF)=5 POLL FREQUENCY/DESTINATION [1] (HEX 0 ... FFFF)=105 POLL FREQUENCY/DESTINATION [2] (HEX 0 ... FFFF)=5 POLL FREQUENCY/DESTINATION [3] (HEX 0 ... FFFF)=5

Type save or quit to exit out of the editor. 7. Verify that the 2760-RB is in chassis 0, group 0 module 0. 8. Save the above configuration.

Publication 2755-6.8

Page 293

15–8

Downloading Match Codes via DH485 using a PLC-5 Processor and a 2760-RB Module

Configuring the Bar Code Reader

This section shows how to configure the AdaptaScan Bar Code Reader (with v7.1 firmware or later) using the AdaptaScan Software (Catalog No. 2755-ASN). The procedures in this section show how to: • define the DeviceNet node address of the AdaptaScan reader • configure a bar code label and symbol • configure the scanner • configure the decoder trigger • configure the serial port • configure the format of messages and the message destination The steps may vary for some procedures because of the different requirements of applications. For example, the bar code labels may vary from one application to the next.

Create a New Project Create a new project named Downloading Match Code for the AdaptaScan Bar Code Readers. 1. Choose New from the Project menu to create a new project. 2. Click the New button to add a bar code reader to the project.

Publication 2755-6.8

Page 294

Downloading Match Codes via DH485 using a PLC-5 Processor and a 2760-RB Module

15–9

3. Choose Edit from the Project menu to rename the project Downloading Match Code.

4. Click Save to save the project under the new name and then Close to return to the Project dialog.

Define the Bar Code Label 1. Click the Labels button to open the Bar Code Labels dialog. 2. Click the New button to define a label.

3. Click the New button to define a symbol for the label.

4. Select a symbology and any other parameters (Identifier, Lengths) required by your application. 5. Click OK until you return to the Bar Code Labels dialog. 6. Click Save and then Close to return to the main Project dialog.

Publication 2755-6.8