The text of a manual · part 13 of 41
AdaptaScan Bar Code Readers (Cat. Nos. 2755-SN3, -SN5, and -SN8) Application Guide: 7 - Communicating with an SLC on a DH-485 Network, pages 107 to 114
Pages 107 to 114 of 354, from AdaptaScan Bar Code Readers (Cat. Nos. 2755-SN3, -SN5, and -SN8) Application Guide
The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort 2755-SN3, Accu-Sort 2755-SN5, Allen-Bradley 2755-SN5, Accu-Sort 2755-SN8 and Allen-Bradley 2755-SN8
Page 107
Communicating with an SLC on a DH-485 Network Overview
This application describes how to connect and configure two AdaptaScan Bar Code Readers to communicate with an SLC 5/03 or 5/04 processor over a DH-485 network in a master mode. The DeviceNet network has the following nodes: • SLC 5/03 or 5/04 on node 1 • AdaptaScan Bar Code Reader on node 2 • AdaptaScan Bar Code Reader on node 3 When configuring a DH-485 network with AdaptaScan Readers, the nodes must be in the following order: • SLC on node 1 • AdaptaScan Readers immediately follow SLC (node 2, node 3,...) • Other network devices (e.g., DTAM Plus) follow the AdaptaScan Readers Avoid node gaps to prevent the AdaptaScan Reader from Soliciting of Successor (SOS). This will maximize bar code throughput as it is sent to the SLC. The priority should be on processing bar code data not on finding node gaps.
Hardware Requirements
The hardware items required for this application are: • 2755-SN3, -SN5 or -SN8 AdaptaScan Bar Code Reader • 2755-NB40 or -NB41 Wiring Base • 2755-PW46 or -PW47 Power Supply • 2755-NC43 or -NC48 Configuration Cable • 1747-L532 or -L54x SLC processor • 1746 Chassis and 24V dc Power Supply • 1747-CP3 RS-232 Programmer Cable • 1747-AIC Isolated Link Coupler or 1761-NET-AIC Advanced Interface Converter • 1747-PIC RS-232/DH-485 Converter • Computer running Windows 3.1 (or later) or Windows 95 • 9-to-25 Pin Adapter (for computer with a 25-pin COM port)
Software Requirements
The software requirements for this application are: • 2755-ASN AdaptaScan Offline Programming Software • 9323-PA2x SLC 500 Advanced Programming Software (The original ICOM SLC software is not compatible with this AdaptaScan network configuration.)
Publication 2755-6.8
Page 108
7–2
Communicating with an SLC on a DH-485 Network
Related Publications
Related publications include: Publication
Description
2755-837
AdaptaScan Bar Code Readers User Manual
2755-838
AdaptaScan Software User Manual
In addition, you may want to refer to the SLC 500 Hardware and Software User Manuals.
Publication 2755-6.8
Page 109
Communicating with an SLC on a DH-485 Network
Connecting a Power Supply to the Reader
7–3
The following illustration shows how to connect a 2755-PW46 or -PW47 power supply to a single bar code reader. The power supply connection applies to both readers. Use a shielded cable (Belden 9316 recommended) to make the connections. Connect the shield to the ground screw on the reader’s wiring base. 2755-PW46 Power Supply
Reader 24V+
V-
Ground Screw on Wiring Base
Connecting to the DH-485 Network
The wiring base of the AdaptaScan Reader has an RS-485/RS-422 terminal block for point-to-point or network connections. This section shows three connection options: • Connecting readers to SLC 5/03 • Connecting readers to SLC 5/04 using two 1747-AIC Modules • Connecting readers to SLC 5/04 using one 1747-AIC Module Note: You can use the 1761-NET-AIC Advanced Interface Converter in place of the 1747-AIC Module. Important:
The DH485 network cable requires proper shielding, grounding and termination. Refer to Data Highway/Data Highway Plus/Data Highway DH485 Cable Installation Manual (Publication No. 1770-6.2.2).
Publication 2755-6.8
Page 110
7–4
Communicating with an SLC on a DH-485 Network
Connecting Readers to SLC 5/03 Controller You must use a link coupler if the distance between the reader and the SLC is greater than 15.2 meters (50 feet). The reader can connect directly to another RS-485/RS-422 device. Point-to-point and network connections are the same. The end devices on the DH-485 network must be terminated. The wiring base of the AdaptaScan Reader provides a termination switch. AdaptaScan Wiring Base RS-422/RS-485 Terminal RS-485/422 RS-485/422
SLC 5/03 Processor
RS-422 RS-422
Power
Ground
Supply
Shield
Termination Switch 1747-AIC Module Term A B Com Shield Chassis Gnd
Computer
AdaptaScan Wiring Base RS-422/RS-485 Terminal 1747-PIC 2755-ASN AdaptaScan Software SLC 500 Advanced Programming Software
Publication 2755-6.8
Page 111
Communicating with an SLC on a DH-485 Network
7–5
Connecting Readers to SLC 5/04 Controller – 2 AIC Modules The SLC 5/04 controller requires two 1747-PIC converters and a power supply to connect to the second 1747-AIC module. The end devices on a DH-485 network must be terminated. The wiring base of the AdaptaScan Reader provides a termination switch. SLC 5/04 Processor
Power Supply
Channel 0 RS-232 1747-PIC AdaptaScan Wiring Base RS-422/RS-485 Terminal DH-485
AdaptaScan Wiring Base RS-422/RS-485 Terminal
1747-AIC Module Term A B Com Shield Chassis Gnd
1747-AIC Module Term A B Com Shield Chassis Gnd
1747-P4 24V dc Power Supply
The 1747-P4 Power Supply provides power to both 1747-AIC modules (1 AMP, 24V dc). Otherwise use 2 power supplies.
Computer
1747-PIC DH-485
RS-232
Publication 2755-6.8
Page 112
7–6
Communicating with an SLC on a DH-485 Network
Connecting Readers to SLC 5/04 Controller – 1 AIC Module The SLC 5/04 controller requires two 1747-PIC converters. However, you can use an RJ48 Y adapter (8-wire LAN phone jack plug) to connect the two 1747-PIC modules. The RJ48 Y adapter is a modular adapter for 4-pair cable which parallels two 4-pair jacks and one 4-pair modular plug. This adapter eliminates the second 1747-AIC module shown on the previous page. The end devices on a DH-485 network must be terminated. The wiring base of the AdaptaScan Reader provides a termination switch. SLC 5/04 Processor
Power Supply
Channel 0 RS-232 1747-PIC AdaptaScan Wiring Base RS-422/RS-485 Terminal DH-485
AdaptaScan Wiring Base RS-422/RS-485 Terminal
1747-AIC Module Term A B Com Shield Chassis Gnd
RJ48 Y Adapter (8-wire LAN Phone Jack Plug) Available from Anixter Company Part No: Hubbell BR851-B Phone: 414-355-0222
Computer
1747-PIC DH-485
Publication 2755-6.8
RS-232
Page 113
Communicating with an SLC on a DH-485 Network
Configuring the SLC Controller
7–7
This section describes how to configure the SLC 5/04, which is different than the 5/03. • Using APS and an RS-232 connection, establish an online connection the Channel 0 port of the SLC 5/04. • When online, change to DH485 protocol and do a WHO ACTIVE to view the nodes on the network. For complete details on configuring the SLC 5/04 or 5/03 processors, refer to the Advanced Programming Software manuals.
SLC 5/04 Configuration 1. Establish communication with the Channel 0 port of the SLC 5/04 using the 1747-CP3/A RS-232 cable. Default On line configuration DF1 Full F7 1200 Enter (twice) On line (in RS-232)
2. Verify that you are online in “REM RUN”. Change configuration driver F2 – PIC Baud Rate 19,200 Max Node 3 F7 Utility F5 Channel 0 (Master Mode) Power down and up
Publication 2755-6.8
Page 114
7–8
Communicating with an SLC on a DH-485 Network
Configuring Bar Code Reader 1
This section shows how to configure one the AdaptaScan Bar Code Readers using the AdaptaScan Software (Catalog No. 2755-ASN). The procedures in this section show how to: • define the DeviceNet node address of the AdaptaScan Reader • configure a bar code label and symbol • configure the scanner • configure the decoder trigger • configure the serial port • configure the format of messages and the message destination The steps may vary for some procedures because of the different requirements of applications. For example, the bar code labels may vary from one application to the next.
Create a New Project Create a new project named DH-485 Master Mode for the AdaptaScan Bar Code Readers. 1. Choose New from the Project menu to create a new project. 2. Click the New button to add a bar code reader (Bar Code Reader 1) to the project.
Publication 2755-6.8