The text of a manual · part 5 of 19
Hand-Held Cordless Bar Code Scanners (Cat. Nos. 2755-HCG-4 and 2755-HCG-7) Programming Guide, pages 36 to 45
Pages 36 to 45 of 176
The original document is the PDF (617 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 2755-DS
Page 36
Basic Bar Codes
1–29
Baud Rate Scan one of the following bar codes to select the appropriate baud rate for RS-232 transmission.
110
300
600
1200
2400
4800
9600*
19200
Publication 2755-6.6
Page 37
1–30
Basic Bar Codes
Parity Scan the appropriate bar code to set the parity of RS-232 transmissions.
Odd*
Even
Mark
Space
None
Publication 2755-6.6
Page 38
Basic Bar Codes
1–31
Check Parity Scan the appropriate bar code to check parity of RS-232 transmissions.
Check Parity*
Do Not Check Parity
Hardware Handshaking Scan the appropriate bar code to select an RS-232 hardware handshaking protocol.
None*
RTS/CTS
Publication 2755-6.6
Page 39
1–32
Basic Bar Codes
Software Handshaking Scan the appropriate bar code to select an RS-232 software handshaking protocol.
None*
ACK/NAK
ACK/NAK with ENQ
ENQ Only
Publication 2755-6.6
Page 40
Basic Bar Codes
1–33
Serial Response Time-Out Scan the Serial Response Time-Out bar code and then the two bar codes corresponding to the desired time-out. The delay can range from zero seconds to 9.9 seconds. If you make an error, scan the Cancel bar code and start again.
Serial Response Time-Out
0
1
2
3
4
5
Publication 2755-6.6
Page 41
1–34
Basic Bar Codes
6
7
8
9
Cancel
Stop Bit Select Scan the appropriate bar code to select the number of stop bits for RS-232 communication.
1 Stop Bit
2 Stop Bits*
Publication 2755-6.6
Page 42
Basic Bar Codes
1–35
ASCII Format Scan the appropriate bar code to select either a 7-bit or 8-bit ASCII format for RS-232 communication.
7-bit*
8-bit
RTS Line State Scan the appropriate bar code to select the desired option.
Line High
Line Low*
Publication 2755-6.6
Page 43
1–36
Basic Bar Codes
Intercharacter Delay Scan the Intercharacter Delay bar code and then the two bar codes corresponding to the desired delay. The delay can range from zero seconds to 0.0099 seconds. If you make an error, scan the Cancel bar code and start again.
Intercharacter Delay
0
1
2
3
4
5
Publication 2755-6.6
Page 44
Basic Bar Codes
1–37
6
7
8
9
Cancel
Transmit Code ID Character Scan the appropriate bar code to enable or disable this parameter.
Transmit Code ID Character
Do Not Transmit Code ID Character *
Publication 2755-6.6
Page 45
1–38
Basic Bar Codes
Transmit AIM Code ID Scan the appropriate bar code to enable or disable this parameter.
Transmit AIM Code ID
Do Not Transmit AIM Code ID*
Ignore Unknown Characters Scan the appropriate bar code to enable or disable this parameter.
Enable*
Disable
Publication 2755-6.6