Page 53

Scanner Configuration (for AdaptaScan Pass Through Cable)

2-19

Select Transmission Format

Send Data As Is (No Prefix / Suffix)

Send Prefix then Data

Send Data then Suffix *

Send Prefix then Data then Suffix

Transmit No-Read Message

Send NR Message with No-Read

Do Not Send NR Message with No-Read*

Publication 2755-6.5

Page 54

2-20

Scanner Configuration (for AdaptaScan Pass Through Cable)

Transmit AIM ID Character

Transmit AIM ID Character

Do Not Transmit AIM ID Character *

Transmit Code ID Character

Transmit Code ID Character

Do Not Transmit Code ID Character *

Publication 2755-6.5

Page 55

Scanner Configuration (for AdaptaScan Pass Through Cable)

2-21

Audible Response

Beep After Decode *

Do Not Beep After Decode

Power Mode Select either one of the power mode options:

Continuous On

Low Power *

Note: When the scanner is in low power mode and a label is scanned, the first character of the first symbol scanned will not be read as the scanner powers up. Use continuous mode if this causes a problem with your application (such as stand mode or A-B Basic Module applications).

Publication 2755-6.5

Page 56

2-22

Scanner Configuration (for AdaptaScan Pass Through Cable)

Laser On Timeout

0.5 Seconds

1.0 Seconds

1.5 Seconds

2.0 Seconds

2.5 Seconds

3.0 Seconds*

Publication 2755-6.5

Page 57

Scanner Configuration (for AdaptaScan Pass Through Cable)

2-23

Laser On Timeout

3.5 Seconds

4.0 Seconds

4.5 Seconds

5.0 Seconds

Publication 2755-6.5

Page 58

2-24

Scanner Configuration (for AdaptaScan Pass Through Cable)

Hands-Free (Stand) Timeout

15 Minutes

30 Minutes

45 Minutes

60 Minutes*

75 Minutes

90 Minutes

Publication 2755-6.5

Page 59

Scanner Configuration (for AdaptaScan Pass Through Cable)

2-25

AdaptaScan Pass Through Cable Configuration This section provides the configuration bar codes for the AdaptaScan pass through cable:

• (Catalog No. 2755-HDC-GA2-08) Scan this label to set the AdaptaScan pass through cable to the following default settings:

Set AdaptaScan Pass Through Cable Defaults Item

Default Setting

Code on Page:

Baud Rate

9600

2-26

Parity

Even➀

2-27

Stop Bits

2➀

2-28

Data Bits

7➀

2-28

Hardware Handshaking

None

2-29

Software Handshaking

None

2-30

Beep on BEL

Disabled

2-31

00

2-32

Intercharacter Delay

➀ We recommend that you set Parity = None, Stop Bits = 1, and Data Bits = 8 for communication with the AdaptaScan Bar Code Reader.

Publication 2755-6.5

Page 60

2-26

Scanner Configuration (for AdaptaScan Pass Through Cable)

AdaptaScan Pass Through Baud Rate

600

1200

2400

4800

9600 *

19200

Publication 2755-6.5

Page 61

Scanner Configuration (for AdaptaScan Pass Through Cable)

2-27

AdaptaScan Pass Through Parity Options

Odd

Even*

Mark

Space

Do Not Check Parity

Publication 2755-6.5