Page 35

Chapter

2

Scanner Configuration (for AdaptaScan Pass Through Cable)

Important: Use the bar codes in this Chapter to configure the scanner for use with the AdaptaScan Pass Through Cable: (Catalog No. 2755-HDC-GA2-08) Do not use these configuration codes if you are using a Synapse cable. Refer to section Scanner Configuration for Synapse Cables. This Chapter also contains the configuration bar codes for the cable beginning on page 2-25.

Before You Configure the Scanner Appendix E provides a condensed version of the scanner configuration and connections that is suitable for many AdaptaScan applications. Appendix E uses default settings with a few modifications that allow communications with an AdaptaScan RS-232 port. Appendix E does not provide codes for all of the options listed in this chapter. An optional method of configuring the scanner is to use the configuration codes in Appendix E and then scan the codes (in this chapter) for items you want to change. Refer to Appendix E before you begin to determine if the condensed version of the configuration meets your application’s requirements. Publication 2755-6.5

Page 36

2-2

Scanner Configuration (for AdaptaScan Pass Through Cable)

Scan These Symbols First Scan all three of these labels in sequence to set the scanner to the default settings for use with an AdaptaScan Pass Through Cable.

Scan this Symbol First then

Set Scanner for AdaptaScan Pass Through Cable Operation

Important: You must then scan the following label to enable the AdaptaScan Pass Through Communications.

Enable AdaptaScan Pass Through Cable Communications

Also scan the ENABLE ADAPTASCAN PASS THROUGH CABLE COMMUNICATION bar code to change the configuration from Synapse communication to the AdaptaScan Pass Through configuration. When AdaptaScan Pass Through communications is enabled, scan the appropriate bar codes to configure the scanner. Then, scan the appropriate bar codes to configure the AdaptaScan Pass Through cable.

Publication 2755-6.5

Page 37

Scanner Configuration (for AdaptaScan Pass Through Cable)

2-3

The scanner is now set to these defaults:

Cable Type

AdaptaScan Pass Through Cable

Code on Page: 2-2

Symbologies

All Enabled

2-4

Transmit UPC-A Check Digit

Enabled

2-8

Transmit UPC-E Check Digit

Enabled

2-8

Convert UPC-E to UPC-A

Disabled

2-8

EAN Zero Extend

Disabled

2-9

Decode UPC / EAN Supplemental

Disabled

2-9

UPC-A Preamble

System Character

2-10

UPC-E Preamble

System Character

2-10

0

2-11

CLSI Editing

Disabled

2-12

NOTIS Editing

Disabled

2-12

Codabar Decode Redundancy

Disabled

2-12

Transmit Code 39 Check Digit

Disabled

2-13

Buffer Code 39

Disabled

2-13

Code 39 Full ASCII

Disabled

2-13

One

2-14

MSI Plessey 2 Check Digit Algorithm

Mod 10 - Mod 10

2-14

Convert Interleaved 2 of 5 (14 digit) to EAN 13 Interleaved Code Length

Disabled

2-15

14

2-15

12

2-15

Item

UPC Security Level/ EAN

MSI Plessey Check Digit

Discrete 2 of 5 Code Length Prefix/Suffix

Default Setting

None

2-17

Data Transmission Format

Suffix Only

2-19

Transmit No-Read Message

Disabled

2-19

Transmit AIM ID Character

Disabled

2-20

Transmit Code ID Character

Disabled

2-20

Beep After Decode

Enabled

2-21

Power Mode

Low Power

2-21

Laser On Timeout

3 Seconds

2-22

Hands-Free Stand Operation Timeout

60 minutes

2-24

Publication 2755-6.5

Page 38

2-4

Scanner Configuration (for AdaptaScan Pass Through Cable)

Select The Symbologies You Want to Enable or Disable

Enable Code 39 *

Disable Code 39

Enable UPC-A *

Disable UPC-A

Enable UPC-E *

Disable UPC-E

Publication 2755-6.5

Page 39

Scanner Configuration (for AdaptaScan Pass Through Cable)

2-5

Select The Symbologies You Want to Enable or Disable

Enable Codabar *

Disable Codabar

Enable EAN 8 *

Disable EAN 8

Enable EAN 13 *

Disable EAN 13

Publication 2755-6.5

Page 40

2-6

Scanner Configuration (for AdaptaScan Pass Through Cable)

Enable Interleaved 2 of 5 *

Disable Interleaved 2 of 5

Enable Discrete 2 of 5 *

Disable Discrete 2 of 5

Enable Code 128 *

Disable Code 128

Enable MSI / Plessey *

Disable MSI / Plessey

Publication 2755-6.5

Page 41

Scanner Configuration (for AdaptaScan Pass Through Cable)

2-7

Select The Symbologies You Want to Enable or Disable

Enable Code 93 *

Disable Code 93

Enable EAN 128 *

Disable EAN 128

Note: The scanner is always enabled to read the Code 128 configuration codes used in this manual.

Publication 2755-6.5

Page 42

2-8

Scanner Configuration (for AdaptaScan Pass Through Cable)

Select UPC / EAN Options

Transmit UPC-A Check Digit *

Do Not Transmit UPC-A Check Digit

Transmit UPC-E Check Digit *

Do Not Transmit UPC-E Check Digit

Convert UPC-E to UPC-A

Do Not Convert UPC-E to UPC-A *

Publication 2755-6.5

Page 43

Scanner Configuration (for AdaptaScan Pass Through Cable)

2-9

Select UPC / EAN Options (Continued)

Decode UPC / EAN Supplemental

Do Not Decode UPC / EAN Supplemental *

Autodiscriminate UPC / EAN with Supplementals

EAN 8 Zero Extend

Do Not Extend EAN 8 *

Publication 2755-6.5