The text of a manual · part 6 of 21
Hand-Held Decoded Bar Code Scanners (Cat. No. 2755-HDG-4) Bar Code Programming Guide: 2 - Scanner Configuration (for AdaptaScan Pass Through Cable), pages 35 to 43
Pages 35 to 43 of 146, from Hand-Held Decoded Bar Code Scanners (Cat. No. 2755-HDG-4) Bar Code Programming Guide
The original document is the PDF (615 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 2755-DS
Page 35
Chapter
2
Scanner Configuration (for AdaptaScan Pass Through Cable)
Important: Use the bar codes in this Chapter to configure the scanner for use with the AdaptaScan Pass Through Cable: (Catalog No. 2755-HDC-GA2-08) Do not use these configuration codes if you are using a Synapse cable. Refer to section Scanner Configuration for Synapse Cables. This Chapter also contains the configuration bar codes for the cable beginning on page 2-25.
Before You Configure the Scanner Appendix E provides a condensed version of the scanner configuration and connections that is suitable for many AdaptaScan applications. Appendix E uses default settings with a few modifications that allow communications with an AdaptaScan RS-232 port. Appendix E does not provide codes for all of the options listed in this chapter. An optional method of configuring the scanner is to use the configuration codes in Appendix E and then scan the codes (in this chapter) for items you want to change. Refer to Appendix E before you begin to determine if the condensed version of the configuration meets your application’s requirements. Publication 2755-6.5
Page 36
2-2
Scanner Configuration (for AdaptaScan Pass Through Cable)
Scan These Symbols First Scan all three of these labels in sequence to set the scanner to the default settings for use with an AdaptaScan Pass Through Cable.
Scan this Symbol First then
Set Scanner for AdaptaScan Pass Through Cable Operation
Important: You must then scan the following label to enable the AdaptaScan Pass Through Communications.
Enable AdaptaScan Pass Through Cable Communications
Also scan the ENABLE ADAPTASCAN PASS THROUGH CABLE COMMUNICATION bar code to change the configuration from Synapse communication to the AdaptaScan Pass Through configuration. When AdaptaScan Pass Through communications is enabled, scan the appropriate bar codes to configure the scanner. Then, scan the appropriate bar codes to configure the AdaptaScan Pass Through cable.
Publication 2755-6.5
Page 37
Scanner Configuration (for AdaptaScan Pass Through Cable)
2-3
The scanner is now set to these defaults:
Cable Type
AdaptaScan Pass Through Cable
Code on Page: 2-2
Symbologies
All Enabled
2-4
Transmit UPC-A Check Digit
Enabled
2-8
Transmit UPC-E Check Digit
Enabled
2-8
Convert UPC-E to UPC-A
Disabled
2-8
EAN Zero Extend
Disabled
2-9
Decode UPC / EAN Supplemental
Disabled
2-9
UPC-A Preamble
System Character
2-10
UPC-E Preamble
System Character
2-10
0
2-11
CLSI Editing
Disabled
2-12
NOTIS Editing
Disabled
2-12
Codabar Decode Redundancy
Disabled
2-12
Transmit Code 39 Check Digit
Disabled
2-13
Buffer Code 39
Disabled
2-13
Code 39 Full ASCII
Disabled
2-13
One
2-14
MSI Plessey 2 Check Digit Algorithm
Mod 10 - Mod 10
2-14
Convert Interleaved 2 of 5 (14 digit) to EAN 13 Interleaved Code Length
Disabled
2-15
14
2-15
12
2-15
Item
UPC Security Level/ EAN
MSI Plessey Check Digit
Discrete 2 of 5 Code Length Prefix/Suffix
Default Setting
None
2-17
Data Transmission Format
Suffix Only
2-19
Transmit No-Read Message
Disabled
2-19
Transmit AIM ID Character
Disabled
2-20
Transmit Code ID Character
Disabled
2-20
Beep After Decode
Enabled
2-21
Power Mode
Low Power
2-21
Laser On Timeout
3 Seconds
2-22
Hands-Free Stand Operation Timeout
60 minutes
2-24
Publication 2755-6.5
Page 38
2-4
Scanner Configuration (for AdaptaScan Pass Through Cable)
Select The Symbologies You Want to Enable or Disable
Enable Code 39 *
Disable Code 39
Enable UPC-A *
Disable UPC-A
Enable UPC-E *
Disable UPC-E
Publication 2755-6.5
Page 39
Scanner Configuration (for AdaptaScan Pass Through Cable)
2-5
Select The Symbologies You Want to Enable or Disable
Enable Codabar *
Disable Codabar
Enable EAN 8 *
Disable EAN 8
Enable EAN 13 *
Disable EAN 13
Publication 2755-6.5
Page 40
2-6
Scanner Configuration (for AdaptaScan Pass Through Cable)
Enable Interleaved 2 of 5 *
Disable Interleaved 2 of 5
Enable Discrete 2 of 5 *
Disable Discrete 2 of 5
Enable Code 128 *
Disable Code 128
Enable MSI / Plessey *
Disable MSI / Plessey
Publication 2755-6.5
Page 41
Scanner Configuration (for AdaptaScan Pass Through Cable)
2-7
Select The Symbologies You Want to Enable or Disable
Enable Code 93 *
Disable Code 93
Enable EAN 128 *
Disable EAN 128
Note: The scanner is always enabled to read the Code 128 configuration codes used in this manual.
Publication 2755-6.5
Page 42
2-8
Scanner Configuration (for AdaptaScan Pass Through Cable)
Select UPC / EAN Options
Transmit UPC-A Check Digit *
Do Not Transmit UPC-A Check Digit
Transmit UPC-E Check Digit *
Do Not Transmit UPC-E Check Digit
Convert UPC-E to UPC-A
Do Not Convert UPC-E to UPC-A *
Publication 2755-6.5
Page 43
Scanner Configuration (for AdaptaScan Pass Through Cable)
2-9
Select UPC / EAN Options (Continued)
Decode UPC / EAN Supplemental
Do Not Decode UPC / EAN Supplemental *
Autodiscriminate UPC / EAN with Supplementals
EAN 8 Zero Extend
Do Not Extend EAN 8 *
Publication 2755-6.5