The text of a manual · part 19 of 21
Hand-Held Decoded Bar Code Scanners (Cat. No. 2755-HDG-4) Bar Code Programming Guide: E - AdaptaScan Pass Through Application
Pages 129 to 133 of 146, from Hand-Held Decoded Bar Code Scanners (Cat. No. 2755-HDG-4) Bar Code Programming Guide
The original document is the PDF (615 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 2755-DS
Page 129
Appendix
E
AdaptaScan Pass Through Application This appendix describes how to configure and operate the scanner when connected to an AdaptaScan Bar Code Reader.
Hardware Connections The scanner connects to the Adaptascan wiring base with a custom cable connected to the AdaptaScan Pass Through cable (Catalog No. 2755-HDC-GA2–08). The cables and connections are shown in Chapter 2 of the scanner user manual (Publication 2755-6.2). AdaptaScan Pass Through Cable
Scanner
Custom Cable (see next page)
Important: Power for the scanner (from package detect terminals) is not provided until the Reader is installed on the wiring base. AdaptaScan Wiring Base
Publication 2755-6.5
Page 130
E–2
AdaptaScan Pass Through Application
The custom cable for the AdaptaScan Pass Through cable connects to the RS-232 and package detect terminals in the AdaptaScan wiring base. 25-Pin Female DB Connector
PKG DET +12VDC
Custom Cable Maximum length of 18 inches (.46 meter)
Ground No Connection
Transmit (Tx)
No Connection
No Connection Receive (Rx) Clear to Send (CTS) Ready to Send (RTS) Shield (SHD)
AdaptaScan Wiring Base
The following table provides the pinout connections for the cable (DB 25-pin female connector). Pass Through Cable Pin Number
Function
AdaptaScan Terminal Connection
2
Receive Data Input
Tx (RS-232 Terminal Block)
3
Transmit Data Output
Rx (RS-232 Terminal Block)
4
CTS Input
RTS (RS–232 Terminal Block)
5
RTS Output
CTS (RS-232 Terminal Block)
7
Ground
GND (Package Detect Terminal Block)
9
+V 4.8 to 14.0V DC
12V (Package Detect Terminal Block)
Shield
Shield Ground
SHD (RS-232 Terminal Block)
Publication 2755-6.5
Page 131
AdaptaScan Pass Through Application
E–3
Configuration Codes for AdaptaScan Pass Through Application 1. After making the necessary connections, scan the following following bar code symbols to setup the scanner for use with the scanner emulation cable.
Scan this Symbol First then
Set Scanner for AdaptaScan Pass Through Cable Operation
Enable AdaptaScan Pass Through Cable Communications
2. Set No Parity.
Do Not Check Parity
3. Set 8 Data Bits.
8 Data Bits
Publication 2755-6.5
Page 132
E–4
AdaptaScan Pass Through Application
4. Set 1 Stop Bit.
1 Stop Bit
5. The cable will now work with the AdaptaScan default communication settings. Your application may have specific requirements. Chapter 8 lists the settings that can be modified. If you change a communication setting, make sure the AdaptaScan RS-232 port is configured to accept the change.
Publication 2755-6.5
Page 133
AdaptaScan Pass Through Application
E–5
AdaptaScan Setup You may need to configure the AdaptaScan RS-232 port to accept the scanner data. Refer to the AdaptaScan Reader Programming Software user manual. Verify that the AdaptaScan serial port is configured as shown below. All settings use the default values except for the Enable Pass-Through to DeviceNet check box.
1. Default is Terminal 2. Default is 9600 Baud 3. Default message length is 0 (sends all data regardless of length). 4. Defaults are: No Parity, 8 Data and 1 Stop Bit. 5. Default is RS-232 Connection 6. Enable Pass-Through
Publication 2755-6.5