Page 129

Appendix

E

AdaptaScan Pass Through Application This appendix describes how to configure and operate the scanner when connected to an AdaptaScan Bar Code Reader.

Hardware Connections The scanner connects to the Adaptascan wiring base with a custom cable connected to the AdaptaScan Pass Through cable (Catalog No. 2755-HDC-GA2–08). The cables and connections are shown in Chapter 2 of the scanner user manual (Publication 2755-6.2). AdaptaScan Pass Through Cable

Scanner

Custom Cable (see next page)

Important: Power for the scanner (from package detect terminals) is not provided until the Reader is installed on the wiring base. AdaptaScan Wiring Base

Publication 2755-6.5

Page 130

E–2

AdaptaScan Pass Through Application

The custom cable for the AdaptaScan Pass Through cable connects to the RS-232 and package detect terminals in the AdaptaScan wiring base. 25-Pin Female DB Connector

PKG DET +12VDC

Custom Cable Maximum length of 18 inches (.46 meter)

Ground No Connection

Transmit (Tx)

No Connection

No Connection Receive (Rx) Clear to Send (CTS) Ready to Send (RTS) Shield (SHD)

AdaptaScan Wiring Base

The following table provides the pinout connections for the cable (DB 25-pin female connector). Pass Through Cable Pin Number

Function

AdaptaScan Terminal Connection

2

Receive Data Input

Tx (RS-232 Terminal Block)

3

Transmit Data Output

Rx (RS-232 Terminal Block)

4

CTS Input

RTS (RS–232 Terminal Block)

5

RTS Output

CTS (RS-232 Terminal Block)

7

Ground

GND (Package Detect Terminal Block)

9

+V 4.8 to 14.0V DC

12V (Package Detect Terminal Block)

Shield

Shield Ground

SHD (RS-232 Terminal Block)

Publication 2755-6.5

Page 131

AdaptaScan Pass Through Application

E–3

Configuration Codes for AdaptaScan Pass Through Application 1. After making the necessary connections, scan the following following bar code symbols to setup the scanner for use with the scanner emulation cable.

Scan this Symbol First then

Set Scanner for AdaptaScan Pass Through Cable Operation

Enable AdaptaScan Pass Through Cable Communications

2. Set No Parity.

Do Not Check Parity

3. Set 8 Data Bits.

8 Data Bits

Publication 2755-6.5

Page 132

E–4

AdaptaScan Pass Through Application

4. Set 1 Stop Bit.

1 Stop Bit

5. The cable will now work with the AdaptaScan default communication settings. Your application may have specific requirements. Chapter 8 lists the settings that can be modified. If you change a communication setting, make sure the AdaptaScan RS-232 port is configured to accept the change.

Publication 2755-6.5

Page 133

AdaptaScan Pass Through Application

E–5

AdaptaScan Setup You may need to configure the AdaptaScan RS-232 port to accept the scanner data. Refer to the AdaptaScan Reader Programming Software user manual. Verify that the AdaptaScan serial port is configured as shown below. All settings use the default values except for the Enable Pass-Through to DeviceNet check box.

1. Default is Terminal 2. Default is 9600 Baud 3. Default message length is 0 (sends all data regardless of length). 4. Defaults are: No Parity, 8 Data and 1 Stop Bit. 5. Default is RS-232 Connection 6. Enable Pass-Through