Page 109

Appendix

B

Flexible Interface Module Application This appendix describes how to configure and operate the scanner when connected to a Flexible Interface Module (Catalog No. 2760-RB).

!

ATTENTION: Do not install the RS-232 Synapse cable with power applied to either the Synapse cable or Flexible Interface Module. Failure to follow this caution may result in damage to the scanner, Synapse cable, or Flexible Interface Module.

For additional reference you should refer to the following publications:

• Flexible Interface Module User Manual (Publication No. 2760-ND001)

• SFC1 or SFC2 Protocol Cartridge User Manuals (Publication No. 2760-ND002 and 2760-822)

Publication 2755-6.5

Page 110

B–2

Flexible Interface Module Application

Hardware Connections The scanner connects to one of the three communication ports on the Flexible Interface Module with an RS-232 Synapse cable (Catalog No. 2755-HFC-SR2-01). The interface module requires an SFC2 Protocol Cartridge.

Power Supply

Scanner Cable

Scanner

RS-232 Synapse Cable (2755-HFC-SR2-01) Note: The power supply should be connected last. SFC2 Protocol Cartridge To RB Nodule Communications Port

Flexible Interface Module

Scanner Configuration Configure the scanner using the bar codes described in Chapter 1. The Flexible Interface Module does not require any specific scanner configuration. However, you will need to configure the cable communication parameters as described on the next page. Publication 2755-6.5

Page 111

Flexible Interface Module Application

B–3

Configuration Codes for Flexible Interface Module Application 7. After making the necessary connections, scan the following following bar code symbols to setup the scanner for use with the scanner emulation cable.

Scan this Symbol First then

Set Scanner for Synapse Cable Operation

Enable Synapse Cable Communication

8. Set the RS-232 Synapse cable to defaults by scanning the following:

Set RS-232 Synapse Cable Defaults

9. The cable defaults will work with the Flexible Interface Module. Your application may have specific requirements. Chapter 3 lists the settings that can be modified. If you change a communication setting, make sure the Flexible Interface Module is configured to accept the change.

Publication 2755-6.5

Page 112

B–4

Flexible Interface Module Application

Flexible Interface Module Setup You will need to configure the Flexible Interface Module. Refer to the user manual for the protocol cartridge and interface module. 1. When configuring the Flexible Interface Module, first select 90B to reset the configuration to factory defaults. 2. Configure screens 3, 21, and 11 (in this order) as shown on the following pages:

Publication 2755-6.5

Page 113

Flexible Interface Module Application

B–5

2760–RB SERIES A REVISION J COPYRIGHT 1989 ALLEN–BRADLEY COMPANY, INC. –––––––––––––––––––––––––––––––––––––––––––––––––––– 1X – CONFIGURATION PARAMETERS 2X – IDENTIFICATION NUMBERS 3 – DEVICE PORT PROTOCOL NAMES 4DM – MATCH CODE ENTRIES 5I – DISCRETE BYTE INPUT ENTRIES 6 – THE DATA MATRIX ENTRIES 7 – THE PASS THROUGH ENTRIES 8 – NON–VOLATILE SCRATCH PAD AREA 9XF – RB MODULE FUNCTIONS AX – HARDWARE DIAGNOSTICS BX – SOFTWARE DIAGNOSTICS C – EXIT CONFIGURATION MODE WHERE X (0 TO 7) AND D (1 TO 3) ARE PORT NUMBERS WHICH ARE DEFINED BELOW : 0 – RB CMMND PRCSS 2 – SERIAL PORT 2 4 – CONFIG PORT 6 – I/O RACK SLT 1 1 – SERIAL PORT 1 3 – SERIAL PORT 3 5 – I/O RACK SLT 0 7 – RESERVED WHERE F (A TO E) ARE FUNCTIONS THAT RB CAN PERFORM WHICH ARE DEFINED BELOW : A – RESET B – SET DEFAULTS C – FLUSH D – INITIALIZE E – CLEAR DIAGS WHERE M (A TO T) AND I (A TO H) ARE ENTRY NUMBERS FOR THE SELECTION MADE ABOVE. ENTER A MAIN MENU SELECTION:

ENTER A MAIN MENU SELECTION: 3 PORT 1 = COPYRIGHT 1989 ALLEN–BRADLEY COMPANY, INC. 2760–SFC1 DT , SERIES A , REVISION B (YES/NO) = YES. PORT 2 = COPYRIGHT 1989 ALLEN–BRADLEY COMPANY, INC. 2760–SFC1 DT , SERIES A , REVISION B (YES/NO) = YES. PORT 3 = COPYRIGHT 1989 ALLEN–BRADLEY COMPANY, INC. 2760–SFC1 DT , SERIES A , REVISION B (YES/NO) = YES. EDIT THIS SELECTION (YES/NO) ?

Publication 2755-6.5

Page 114

B–6

Flexible Interface Module Application

ENTER A MAIN MENU SELECTION: 21 DUMB TERM. UNSPECIFIED PROTOCOL, 13fh (YES/NO) = YES. EDIT THIS SELECTION (YES/NO) ?

ENTER A MAIN MENU SELECTION: 11 MODEM CONTROL (ENABLE/DISABLE) = DISABLE. 9600 BITS PER SECOND (YES/NO) = YES. 8 BITS NO PARITY (YES/NO) = YES. XON/XOFF (ENABLE/DISABLE) = DISABLE. RS232 (YES/NO) = YES. RECEIVE MATRIXING (ENABLE/DISABLE) = DISABLE. BYTE SWAPPING (ENABLE/DISABLE) = ENABLE. BINARY DATA NO CONVERSIONS (YES/NO) = YES. HDR/TLR ON OUTPUT (ENABLE/DISABLE) = ENABLE. HEADER BYTE LENGTH (DEC 0...4) = 0. HEADER DATA[0] (HEX 0...ff) = 0. HEADER DATA[1] (HEX 0...ff) = 0. HEADER DATA[2] (HEX 0...ff) = 0. HEADER DATA[3] (HEX 0...ff) = 0. TRAILER BYTE LENGTH (DEC 0...4) = 2. TRAILER DATA[0] (HEX 0...ff) = a. TRAILER DATA[1] (HEX 0...ff) = d. TRAILER DATA[2] (HEX 0...ff) = 0. TRAILER DATA[3] (HEX 0...ff) = 0. MAX DATA BYTE LENGTH (DEC 0...124) = 0. MIN DATA BYTE LENGTH (DEC 0...124) = 0. CONTINUE THIS SELECTION (YES/NO) ?

3. Make sure PLC program is written to access Flexible Interface Module data. Publication 2755-6.5