Page 68

Chapter

3

RS-232 Synapse Cable (Communication Setup) This chapter provides the configuration bar codes for the following RS-232 Synapse cables:

• (Catalog No. 2755-HFC-SR2-01) • (Catalog No. 2755-HFC-SR3-01)

Publication 2755-6.5

Page 69

3-2

RS-232 Synapse Cable (Communication Setup)

Set RS-232 Synapse Cable Defaults Scan this label to set the default settings for the RS-232 Synapse cable. Defaults are indicated with an asterisk.

Set RS-232 Synapse Cable Defaults

Scan this label to set the RS-232 Synapse cable to the default settings shown below.

Standard RS-232

Code on Page: 3-3

Baud Rate

9600

3-4

Parity

None

3-5

Check Parity

Enabled

3-5

Stop Bits

1

3-6

Data Bits

8

3-6

RTS State

Low

3-7

Hardware Handshaking

None

3-7

Software Handshaking

None

3-8

Beep on BEL

Disabled

3-9

Item Host

Default Setting

Unknown Characters

Send Bar Codes With Unknown Characters

3-9

Response Timeout

2 Seconds

3-10

Set #1

3-12

Parameter Set

Scan the bar code symbols for the settings you need to change.

Publication 2755-6.5

Page 70

RS-232 Synapse Cable (Communication Setup)

3-3

RS-232 Synapse Cable Fixed Format Hosts Currently only one option for fixed format hosts is available. Scan the Standard RS-232 host bar code symbol. Additional hosts may be added at a future date.

Standard RS-232 *

Publication 2755-6.5

Page 71

3-4

RS-232 Synapse Cable (Communication Setup)

RS-232 Synapse Cable Baud Rate

110

300

600

1200

2400

4800

9600 *

19200

Publication 2755-6.5

Page 72

RS-232 Synapse Cable (Communication Setup)

3-5

RS-232 Synapse Cable Parity Options

None *

Odd

Even

Mark

Space

Check Parity*

Do Not Check Parity

Publication 2755-6.5

Page 73

3-6

RS-232 Synapse Cable (Communication Setup)

RS-232 Synapse Cable Stop and Data Bits

One Stop Bit *

Two Stop Bits

8 Data Bits *

7 Data Bits

Publication 2755-6.5

Page 74

RS-232 Synapse Cable (Communication Setup)

3-7

RS-232 Synapse Cable Hardware Handshaking

No Hardware Handshaking*

RTS / CTS Enable

RTS Low *

RTS High

Publication 2755-6.5

Page 75

3-8

RS-232 Synapse Cable (Communication Setup)

RS-232 Synapse Cable Software Handshaking

No Software Handshaking*

ACK / NAK

ENQ Only

ACK / NAK with ENQ

XON / XOFF

Publication 2755-6.5

Page 76

RS-232 Synapse Cable (Communication Setup)

3-9

RS-232 Synapse Cable Beep On <BEL>

Do Not Beep on <BEL> *

Beep on <BEL>

RS-232 Synapse Cable Unknown Characters

Send Bar Codes with Unknown Characters *

Do Not Send Bar Codes with Unknown Characters

Publication 2755-6.5

Page 77

3-10

RS-232 Synapse Cable (Communication Setup)

RS-232 Synapse Cable Response Timeout Scan the following symbol followed by the two digit timeout from 0.0 to 9.9 (default is 2.0 seconds).

Enter Response Timeout

0

1

2

3

4

Publication 2755-6.5

Page 78

RS-232 Synapse Cable (Communication Setup)

3-11

5

6

7

8

9

Cancel (Clears Entry)

Publication 2755-6.5

Page 79

3-12

RS-232 Synapse Cable (Communication Setup)

RS-232 Synapse Cable Advanced Features Scan the following symbols to select the current parameter set and/or set the defaults for each parameter set.

Parameter Set 1 *

Parameter Set 2

Set Cable Defaults Current Parameter Set

Set Cable Defaults Both Parameter Sets

Publication 2755-6.5