The text of a manual · part 6 of 17
2-D Hand-Held Bar Code Scanners (Cat. No. 2755-HTG-4) User Manual: 4 - Configuring the Scanner
Pages 48 to 61 of 134, from 2-D Hand-Held Bar Code Scanners (Cat. No. 2755-HTG-4) User Manual
The original document is the PDF (644 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 2755-DS
Page 48
Chapter
4
Configuring the Scanner This chapter describes the scanner configuration options.
Important Notes on Configuring Scanner • Bar codes for configuring the scanner and Synapse cable are located in the Programming Guide for 2-D Bar Code Scanners (Publication 2755-6.7). • Configure the scanner. • Configure the Synapse cable. Separate configuration codes are scanned to configure the cable. Chapter 5 describes the communication setup (cable configuration) codes for the RS-232, keyboard wedge cable, scanner emulation.
Configuration Bar Codes for Scanner All configuration bar codes are found in the Programming Guide for 2-D Bar Code Scanners (Publication 2755-6.7). The scanner is always enabled to read Code 128 configuration bar codes since all configuration codes use this symbology.
Publication 2755-6.4
Page 49
4–2
Configuring the Scanner
Configuring the Scanner 1. Connect the appropriate Synapse cable to the scanner. 2. Apply power to the Synapse cable (if required). 3. Scan the Set Defaults bar code (in the Programming Guide for 2-D Bar Code Scanners) to configure the scanner with default settings. Table 4.A lists the scanner default settings. 4. Scan individual bar codes (in the Programming Guide for 2-D Bar Code Scanners) for parameters you want to change. 5. Scan the communication bar codes for the Synapse cable.
Scanner Default Settings Table 4.A Scanner Default Settings Configuration Parameters
Default Setting
Programming Guide Reference 1-1
Set Default
Set Defaults
Symbologies
All Enabled, except I 2 of 5, and Codabar
1-3
Code 39 Full ASCII
Enabled
1-6
Code 39 Check Digit
Disabled
1-6
Transmit UPC-A Check Digit
Enabled
1-7
Transmit UPC-E Check Digit
Enabled
1-7
Convert UPC-E to UPC-A
Disabled
1-7
Decode UPC / EAN Supplemental
Disabled
1-8
Convert EAN-8 to EAN-13
Disabled
1-8
UPC-A Preamble
System Character
1-9
UPC-E Preamble
System Character
1-9
Code 39 Options
UPC/EAN Options
Publication 2755-6.4
Page 50
Configuring the Scanner
4–3
Default Setting
Programming Guide Reference
None
1-10
Code 39 – Length Within Range
Range (1-55)
1-10
Code 39 – 1 Discrete Length
None
1-10
Code 39 – 2 Discrete Lengths
None
1-10
Codabar – Any Length
Range (2-55)
1-11
Codabar – Length Within Range
Range (2-55)
1-11
Codabar – 1 Discrete Length
None
1-11
Codabar – 2 Discrete Lengths
None
1-11
Interleaved 2 of 5 – Any Length
Range (2-54)
1-12
Interleaved 2 of 5 – Length Within Range
None
1-12
Interleaved 2 of 5 – 1 Discrete Length
14
1-12
Interleaved 2 of 5 – 2 Discrete Lengths
None
1-12
Enter
1-14
Data Transmission Format
<Data> As Is
1-16
Transmit No Read Message
Disabled
1-17
Transmit LRC Checksum
Disabled
1-17
Transmit Code ID Character
Disabled
1-18
Beep After Good Decode
Enabled
1-19
Beeper Tone
High
1-19
Decode Buffering
Disabled
1-19
Pause Duration
0.0 seconds
1-20
Decode Attempt Duration
5 seconds
1-20
Smart Raster Mode
Enabled
1-22
Hand-Held Options
Slab Raster
1-22
Configuration Parameters Code Lengths Code 39 – Any Length
Data Format Options Prefix/Suffix
Decode Options
Scanning Options
Publication 2755-6.4
Page 51
4–4
Configuring the Scanner
Set Defaults Scan the Set Defaults bar code to return all parameters to the default values listed in Table 4.A.
Select Symbologies Scan the bar code labels for the symbologies you want the scanner to decode. Only enable the symbologies you expect to read. The scanner automatically discriminates between all of the symbologies below. The only exception is that the scanner cannot discriminate between Code 39 and Code 39 Full ASCII.
• • • • • • •
UPC Versions A and E (EAN 8 and 13) Code 39 (Code 39 Full ASCII) Codabar UCC/EAN 128 Interleaved 2 of 5 Discrete 2 of 5 PDF417
By default, all symbologies are enabled except Interleaved 2 of 5 and Codabar. To enable a symbology, scan the Enable bar code for the symbology. To disable a symbology, scan the Disable bar code. You can enable all code types (only Code 39 Full ASCII is disabled).
Publication 2755-6.4
Page 52
Configuring the Scanner
4–5
Code 39 Options Code 39 Full ASCII The ASCII character set assigns a code to letters, punctuations marks, numerals, and most control keystrokes on the keyboard. The first 32 codes are non-printable and are assigned to keyboard control keys, such as Backspace and Return. The other 96 are called printable codes because all but Space and Delete produce visible characters. Code 39 Full ASCII interprets the bar code control characters ($ + % /) preceding a Code 39 symbol and assigns an ASCII character value. For example, when +B is scanned, it is interpreted as b, %J as ?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M outputs the keystroke equivalent ABC ENTER. Refer to Appendix C for a list of the Code 39 Full ASCII codes. The scanner cannot autodiscriminate between Code 39 and Code 39 Full ASCII symbols. Code 39 Check Digit When enabled, this parameter checks the integrity of a Code 39 symbol to ensure that is complies with specified algorithms.
Publication 2755-6.4
Page 53
4–6
Configuring the Scanner
UPC / EAN Options The section defines options available for UPC-A and UPC-E codes. Transmit UPC-A Check Digit When enabled, UPC-A symbol data is transmitted with the check digit. Enabled is the default. Transmit UPC-E Check Digit When enabled, UPC-E symbol data is transmitted with the check digit. Enabled is the default. Convert UPC-E to UPC-A When enabled, this option converts UPC-E (zero suppressed) decoded data to a UPC-A format before transmission. After conversion, the output data follows UPC format and follows UPC-A programming selections (e.g., preamble, check digit). Disabled is the default. Decode UPC / EAN Supplemental The options for decoding UPC/EAN supplemental digits are: • Enabled – supplemental digits are decoded (2 or 5 according to specific code format conventions, e.g., UPC A+2, UPC E+2, EAN 8+2). Only symbols with supplemental digits are decoded. • Disabled – supplemental digits are ignored even if present. Disabled is the default. • Autodiscriminate – codes with and without supplemental digits are decoded. To minimize the risk of invalid data transmission, we recommend that you select whether to read or ignore supplemental characters.
Publication 2755-6.4
Page 54
Configuring the Scanner
4–7
UPC / EAN Options (Continued) Convert EAN-8 to EAN-13 When enabled, five leading zeros are added to decoded EAN 8 symbols. The five zeros make the EAN 8 symbols compatible with the EAN 13 format. Disabled is the default. UPC-A / UPC-E Preambles Three options are available for the lead-in characters of decoded UPC-A or UPC-E symbols transmitted to the host device. Select one preamble for UPC-A decodes and one for UPC-E decodes. The preamble is considered a part of the symbol. The three options are:
• system character only • country code and system character • no preamble The system character is the the first character on the left side of the symbol. The country code for UPC is always 0, and cannot be transmitted without the system character. System character is the default.
Publication 2755-6.4
Page 55
4–8
Configuring the Scanner
Code Lengths The length of a code refers to the number of characters (human readable characters) the code contains. You can set the code length for certain one-dimensional code types (Code 39, Codabar, Interleaved 2 of 5) to any length, one or two disrete lengths, or lengths within a specific range. You cannot set a discrete length for Code 128. Any Length Select this option to decode a one-dimensional code containing any number of characters. For example, to scan a Codabar symbol containing any number of characters, scan Codabar Any Length. Length Within Range Select this option to decode a one-dimensional code containing a length within a specified range. For example, to decode Code 39 codes containing between 4 and 12 characters, scan the Code 39 Length Within Range code. Then scan, 0, 4, 1, 2. Single digit numbers must be preceded with a zero. One Discrete Length Select this option to decode only one-dimensional codes containing a selected length. For example, to decode Codabar codes containing 14 characters, scan Codabar – One Discrete Length. Then scan 1 and 4. Two Discrete Lengths Select this option to decode only one-dimensional codes containing two selected lengths. For example, to decode Interleaved 2 of 5 codes containing 2 or 14 characters, scan Interleaved 2 of 5 – Two Discrete Lengths. Then scan 0, 2, 1, 4. Single digit numbers must be preceded with a zero. Publication 2755-6.4
Page 56
Configuring the Scanner
4–9
Data Format Options Prefix / Suffix You can add a prefix/suffix to bar code data. To enter a prefix/suffix, you must scan a four digit number (four bar codes) that represents the ASCII equivalent value for each character (See ASCII Characters in Appendix C). When you enter the last digit of a prefix or suffix, the scanner lets you know that you have entered a valid value by providing a high-low-high beep. The default prefix/suffix is the ENTER key (ASCII equivalent 1073). For example, to add the prefix < (ASCII equivalent 1060) to bar code data, scan these labels:
– – – – –
Prefix 1 (under Prefix/Suffix Values) 0 (under Prefix/Suffix Values) 6 (under Prefix/Suffix Values) 0 (under Prefix/Suffix Values)
For example, to add the suffix > (ASCII equivalent 1062) to bar code data, scan these labels:
– – – – –
Suffix 1 (under Prefix/Suffix Values) 0 (under Prefix/Suffix Values) 6 (under Prefix/Suffix Values) 2 (under Prefix/Suffix Values)
Transmit No Read Message When enabled, this option transmits “NR” when a symbol does not decode. Enabled prefixes and suffixes are appended around this message. The default is disabled. Publication 2755-6.4
Page 57
4–10
Configuring the Scanner
Data Format Options (continued) Data Transmission Format You can specify whether or not the prefix and/or suffix is added to decoded bar code data. The options are listed below. <Data>
Sends only bar code data.
<Prefix><Data>
Sends bar code data with a prefix
<Data><Suffix>
Sends bar code data with a suffix
<Prefix><Data><Suffix>
Sends bar code data with a prefix and suffix
The prefix and suffix are user defined. For example, the prefix [ and suffix ] are defined for bar code data. To send the decoded bar code data with the prefix only, scan these labels:
– Scan This Symbol First – <Prefix><Data> – Scan Enter After Selecting Option Transmit LRC Checksum When enabled, this option appends an LRC checksum character at the end of a decode transmission. The default is disabled. With LRC Checksum enabled, the format of the output data is: <STX> <DATA . . . > <ETX> <LRC> . If <DATA . . . > contains the special characters STX, ETX, and DLE, the DLE character is used as an escape character and is added before each of those characters so that the receiving side knows not to interpret the special characters in the data as control characters. The LRC character is the exclusive OR of all characters except for the LRC character itself.
Publication 2755-6.4
Page 58
Configuring the Scanner
4–11
Transmit Code ID Character When enabled, this option transmits a code ID character or an AIM ID character to identify the code type of the symbol scanned. This option is useful if you are scanning more than one code type. If a prefix is defined, the code ID character is sent after the prefix and before the decoded symbol. The default is to not transmit a Code ID character. Code ID characters are listed below. AIM ID characters are listed in Appendix D. Code Type
Code Identifier (ID)
UPC-A, UPC-E, EAN-13, EAN-8
A
Code 39
B
Codabar
C
Code 128
D
Code 93
E
Interleaved 2 of 5
F
Discrete 2 of 5, D 2 of 5 IATA
G
UCC/EAN 128
K
PDF417
X
Publication 2755-6.4
Page 59
4–12
Configuring the Scanner
Decode Options Beep After Good Decode When enabled, the beeper sounds during scanning. We recommend that you operate the unit with the beeper enabled. The default is enabled. The beeper always operates during parameter menu scanning and indicates error conditions. See page 3–8 for beeper indications. Beeper Tone Sets the decode beep frequency or tone to low, medium or high. The default is high. Decode Buffering When enabled, this option allows the scanner to store decoded data until the host device is ready to receive them. If the scanner reaches its capacity for storing decoded symbols before the host is ready, subsequent triggers have no effect until the buffer is available. The default is disabled. Pause Duration This parameter inserts a pause after a bar code is scanned to allow time for the data to be decoded and transferred to the host. You can set a pause duration in .1 (1/10) second intervals from 0.1 to 9.9 seconds. Pauses are set by scanning a two digit number. The default is 0.0 seconds. For example, to set a .5 (1/2) second delay, scan the following labels:
– Pause Duration – 0 (under Pause Duration) – 5 (Under Pause Duration)
Publication 2755-6.4
Page 60
Configuring the Scanner
4–13
Decode Attempt Duration Sets the maximum time decode processing continues during a scan attempt. You set the duration in .1 second increments from 0.1 to 9.9 seconds. The recommended interval is between 1.0 and 5.0 seconds. The default is 5.0 seconds. A longer interval is appropriate for PDF417 symbols that are hard to decode. The duration is set by scanning a two digit number. For example, to set the interval to 6.0 seconds, scan the labels:
– Decode Attempt Duration – 6 (under Pause Duration) – 0 (Under Pause Duration)
Publication 2755-6.4
Page 61
4–14
Configuring the Scanner
Scanning Options Smart Raster Mode When enabled, Smart Raser Mode automatically detects the height of the PDF417 symbol and expands the raster pattern to cover the symbol vertically. Change this mode only if the raster pattern cannot cover a poorly printed symbol. The default is Smart Raster enabled. Hand–Held Options Select the scanning pattern. • Slab raster – In this mode, a trigger pull yields a slab raster pattern. This is the default. • Aiming dot – In this mode, a trigger pull creates a bright aiming dot. The aiming dot helps you to center the pattern while aiming the scanner, especially in bright light conditions. You can select aiming dot with either a normal timeout or an extended timeout. Depending on the selected option, a standard slab raster or an open raster appears when the dot expires. • Always raster – When Always Raster is enabled, a trigger pull causes the scanner to open a full raster pattern. Always Raster does not exclude aiming dot or slab raster options because a raster always follows when the aiming dot expires.
Publication 2755-6.4