Page 25
Chapter
2
Connecting the Scanner This chapter describes how to connect the scanner to various cables and hardware. Sections include: • Scanner cable connection • Scanner Emulation Synapse cable connections • RS-232 Synapse cable connections • Keyboard Wedge Synapse cable connections • Allen-Bradley Enhanced Decoder connection • Flexible Interface Module (RB) connection • PLC connection • SLC connection
Safety
!
ATTENTION: Caution - use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure.
Publication 2755-6.4
Page 26
2–2
Connecting the Scanner
Overview The scanner may be connected to a variety of host devices through a synapse cable. The communication parameters for the cables are configured by scanning bar codes. The three types of cables are: • RS-232 Synapse cable • Keyboard Wedge Synapse cable • Scanner Emulator Synapse cable All configuration bar codes are in the Programming Guide for 2-D Bar Code Scanners.
Publication 2755-6.4
Page 27
Connecting the Scanner
2–3
Scanner Cable Connection The scanner cable (Catalog No. 2755-HTC-GS1-08) connects to the bottom of the scanner handle. The other end of the scanner cable connects to the Synapse cable.
Locking Collar Connector Cable Connector Slot for Tab on Collar
To attach the cable to the scanner: 1. Pull back the locking collar from the connector. 2. Insert the cable connector into the scanner. 3. Align the tabs on the locking collar with the slots on the handle. 4. Push in and turn the locking collar counterclockwise to lock. Connector is locked when flat edge of locking collar aligns with the front edge of the scanner handle. Remove a scanner cable from a scanner by rotating the locking collar clockwise until the cable be pulled out of the scanner. Publication 2755-6.4
Page 28
2–4
Connecting the Scanner
Scanner Cable to Synapse Cable Connection To connect the scanner cable to a Synapse cable, push the cable into the connector until you hear the connector snap in place. To remove the scanner cable, press down on the small raised bump on the connector end and remove cable.
Scanner
Scanner Cable
Press Here to Remove
Synapse Cable (2755-HFC-SR3-01 shown)
Publication 2755-6.4
Page 29
Connecting the Scanner
2–5
Scanner Emulation Synapse Cable Connections Use the Scanner Emulation Synapse cable to provide undecoded output to a scanner input port of a bar code decoder (cable has female 9-pin DB connector).
Catalog No. 2755-HFC-SA1-01
A separate power supply provides power to the scanner. The power supply plugs into the Scanner Emulation Synapse cable. Power Supply
Scanner Cable
Scanner
Scanner Emulation Synapse Cable (2755-HFC-SA1-01) Note: Connect the power supply last.
To Bar Code Decoder
!
ATTENTION: Do not install the Scanner Emulation Synapse cable with power applied to either the Synapse cable or decoder. Failure to follow this caution may result in damage to the scanner, Synapse cable, or decoder.
Publication 2755-6.4
Page 30
2–6
Connecting the Scanner
RS-232 Synapse Cable Connections Use the RS-232 Synapse cable to connect the scanner to any host RS-232C input port. Two types of RS-232 Synapse cables are available:
Catalog No. 2755-HFC-SR2-01
Catalog No. 2755-HFC-SR3-01
RS-232 Synapse Cable
Output Connector
Output Signal
2755-HFC-SR2-01
Male 25-pin DB
RS-232C, Txd on Pin #3
2755-HFC-SR3-01
Female 9-pin DB
RS-232C, Txd on Pin #2
!
ATTENTION: Do not install the RS-232 Synapse cable with power applied to either the Synapse cable or host device. Failure to follow this caution may result in damage to the scanner, Synapse cable, or host device.
Publication 2755-6.4
Page 31
Connecting the Scanner
2–7
Connect the scanner to an RS-232 port as shown below. A separate power supply provides power to the scanner. The power supply plugs into the RS-232 Synapse cable. Scanner Scanner Cable Power Supply
RS-232 Synapse Cable (2755-HFC-SR3-01 shown) Note: Connect the power supply last. To Host RS-232 Port
Host with RS-232 Port
Publication 2755-6.4
Page 32
2–8
Connecting the Scanner
Keyboard Wedge Synapse Cable Connections Use the Keyboard Wedge Synapse cable to connect the scanner between a keyboard and a host device. The host device interprets the decoded scanner output the same as keyboard data. Four types of Keyboard Wedge Synapse cables are available:
Catalog No. 2755-HFC-SP1-01
Catalog No. 2755-HFC-SP2-01
Catalog No. 2755-HFC-SV1-01
Catalog No. 2755-HFC-SV2-01
Keyboard Wedge Synapse Cable
For Keyboard Type:
2755-HFC-SP1-01
IBM AT/XT Keyboard (5-pin DIN)
2755-HFC-SP2-01
PS/2 Keyboard (6-pin Mini-DIN)
2755-HFC-SV1-01
DEC VT220/320/420
2755-HFC-SV2-01
DEC VT520
A separate power supply plugs into the Synapse cable and provides power to the scanner. The following wedge cable applications may not require the power supply if the host provides adequate power for the scanner (depends on system configuration): • IBM PC/AT • IBM PS / 2-50, 55SX, 60, 70, 80 • IBM PC/XT and compatibles • IBM PS/2-30 Publication 2755-6.4
Page 33
Connecting the Scanner
Power Supply (May not be required, see previous page.)
2–9
Scanner Scanner Cable
Wedge Synapse Cable (2755-HFC-SP1-01 shown) Note: Connect the power supply last. To Host Keyboard Connector
To Keyboard
To connect the scanner cable to the keyboard wedge cable, push the cable into the connector until you hear the connector snap in place. To remove the scanner cable, press down on the small raised bump on the connector end and remove cable.
!
ATTENTION: Do not install the wedge cable or disconnect/connect the keyboard with power applied to either the wedge cable or host device. Failure to follow this caution may result in damage to the scanner, wedge interface cable, or host device.
The Wedge Synapse cable connects between the keyboard and the host device. Unplug the keyboard and connect one end of the wedge cable to the host keyboard input. Connect the other end of the wedge interface cable to the keyboard. Publication 2755-6.4
Page 34
2–10
Connecting the Scanner
Scanner to Enhanced Decoder Scanner Port Connection Use the Scanner Emulation Synapse cable (Catalog No. 2755-HFC-SA1-01) and Gun Adapter (Catalog No. 2755-NC16, Series B) to connect the scanner cable to a scanner port on the Allen-Bradley Enhanced Decoders (2755-DS1/DD1).
Scanner Power Supply
Scanner Cable
Scanner Emulation Synapse Cable (2755-HFC-SA1-01) Note: Connect the power supply last.
Gun Adapter (Catalog No. 2755-NC16)
Allen-Bradley Enhanced Decoder (2755-DS1/DD1)
Publication 2755-6.4
Page 35
Connecting the Scanner
2–11
Scanner to Enhanced Decoder Aux Port Connection Use the 25-pin RS-232 Synapse cable (Catalog No. 2755-HFC-SR2-01) to connect the scanner cable to Aux port on the Allen-Bradley Enhanced Decoders (2755-DS1/DD1).
Scanner Scanner Cable
Power Supply
25-pin RS-232 Synapse Cable (2755-HFC-SR2-01) Note: Connect the power supply last.
Null Modem Adapter
Allen-Bradley Enhanced Decoder (2755-DS1/DD1)
Publication 2755-6.4
Page 36
2–12
Connecting the Scanner
Scanner to Flexible Interface (RB) Module Connection Use the 25-Pin RS-232 Synapse cable (Catalog No. 2755-HFC-SR2-01) to connect the scanner cable to a port on the Flexible Interface Module (Catalog No. 2760-RB). The protocol cartridges (Catalog No. 2760-SFC1, -SFC2) support RS-232 communications. Scanner Scanner Cable
Power Supply
RS-232 Synapse Cable (2755-HFC-SR2-01) Note: Connect the power supply last. SFC1, SFC2 Protocol Cartridge
To RB Module Communications Port
Flexible Interface Module
Refer to the user manual for the Flexible Interface Module for the proper configuration. Make sure the Synapse cable communications settings match the Flexible Interface Module settings for the port.
Publication 2755-6.4
Page 37
Connecting the Scanner
2–13
Scanner to PLC Connection Use the 25-Pin RS-232 Synapse cable (Catalog No. 2755-HFC-SR2-01) to connect the scanner cable to the Channel 0 port of a PLC-5. The Channel 0 port must be configured for RS-232 communications. Scanner Power Supply
Scanner Cable
RS-232 Synapse Cable (2755-HFC-SR2-01) Note: Connect the power supply last. PLC-5
To Channel 0 Port
Refer to the user manuals for the Allen-Bradley 6200 Series Programming Software to make sure the Channel 0 settings match the Synapse cable settings.
Publication 2755-6.4
Page 38
2–14
Connecting the Scanner
Scanner to SLC Connection Use the 9-Pin RS-232 Synapse cable (Catalog No. 2755-HFC-SR3-01) to connect the scanner cable to the Channel 0 port on an SLC-5/03 or 5/04. The Channel 0 port must be configured for RS-232 communications.
Scanner Scanner Cable
Power Supply
RS-232 Synapse Cable (2755-HFC-SR3-01) Note: Connect the power supply last. SLC 5/04
To Channel 0 Port
Channel 0
Refer to the user manuals for the Allen-Bradley Advanced Programming Software (APS) to make sure the Channel 0 settings match the Synapse cable settings.