The text of a manual · part 8 of 16
Hand-Held Cordless Bar Code Scanners (Cat. Nos. 2755-HCG-4 and 2755-HCG-7) User Manual: 3 - Configuring Your Scanner, pages 54 to 59
Pages 54 to 59 of 107, from Hand-Held Cordless Bar Code Scanners (Cat. Nos. 2755-HCG-4 and 2755-HCG-7) User Manual
The original document is the PDF (451 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 2755-DS
Page 54
Configuring Your Scanner
3–17
Parity Checks to ensure that the correct number of bits are contained in the coded character. You can set the parity of each ASCII coded character that is transmitted. Make sure the parity matches the requirements of the host. The selections are: • Odd • Even • Mark (parity bit always set to 1) • Space (parity bit always set to 0) • None (Default) Check Parity When enabled, the scanner checks the received characters for parity. The type of parity can be selected with the Parity parameter. The default parameter is Check Parity enabled. Hardware Handshaking When enabled, handshaking verifies the readiness of a receiving device before data is transmitted. If the receiving device is periodically occupied with other tasks, hardware handshaking is used to prevent loss of transmitted data. You can enable or disable the hardware handshaking lines, RTS (Request to Send), and CTS (Clear to Send). The DTR (Data Terminal Ready) signal is active high. Hardware handshaking cannot be used in conjunction with software handshaking. If RTS/CTS handshaking is enabled, the sequence for scanning data is: 1. The base/charger unit checks the Clear to Send (CTS) line. If CTS is active, the base/charger unit will wait for up to one second and check the line again. If the line is still active, the base/charger unit will provide an audible beep and any scanned data will be lost. Publication 2755-6.3
Page 55
3–18
Configuring Your Scanner
2. If the CTS line is not active, the base/charger unit will assert the Request to Send (RTS) line and waits one second for the host to assert the CTS line. When the host asserts the CTS line, the base/charger unit transmits the data. During the transmission of data, the CTS line should be asserted. 3. After the transmission is completed, the base/charger unit will negate the RTS 10 msec after sending the last character. 4. The host device should then negate CTS. The base/charger unit checks the CTS line on the next transmission. If the sequence for scanning data fails, the base/charger unit issues a transmit error, indicating that the data is lost and must be rescanned. The default parameter is no Hardware Handshaking enabled. Software Handshaking Software handshaking controls the transmission of data. Use software handshaking instead of (but not with) hardware handshaking. There are four options: • None (Default) • ACK/NAK Only • ENQ Only • ACK/NAK with ENQ ACK/NAK Only checks the result of a transmission. The base/charger unit waits for one of the following responses from the host: • <ACK> • <NAK> ACK indicates a successful transmission. NAK indicates there is a problem. Whenever the scanner receives a NAK, it retransmits the data up to three times. If an ACK is still not received after three attempts, the transmission is aborted and the scanner will provide four short beeps. Publication 2755-6.3
Page 56
Configuring Your Scanner
3–19
ENQ ONLY requires that the base/charger unit receive an an enquire character (ENQ) from the host before sending data. With ENQ enabled, the base/charger unit must receive an ENQ from the host within a two second period after the last scan or a transmission error occurs. The scanner will provide four short beeps to indicate the error; the base/charger unit is ready to send again. ACK/NAK with ENQ combines both ACK/NAK and ENQ options. Serial Response Time-out When enabled, this parameter determines the maximum period allowed to elapse before the base/charger unit assumes the end of transmission. The delay can last up to 9.9 seconds. The default parameter is enabled at 2 seconds. Stop Bit Select The stop bit marks the end of each character transmitted and prepares the receiving device for the next character in the data stream. You can set the number of stop bits to either 1 or 2 to match the host device. The default parameter is set to 2. ASCII Format When enabled, the scanner transmits data in an 8-bit ASCII format. This allows the the base/charger unit to interface with devices using that protocol. The default is 7-bit ASCII. RTS Line State When enabled, the parameter adjusts the RTS Line State since certain hosts expect the RTS line to be in a certain state (high or low). The default parameter is set to low.
Publication 2755-6.3
Page 57
3–20
Configuring Your Scanner
Intercharacter Delay When enabled, the host system has time to service its receiver and perform other tasks between characters. You can choose up to 99 msec delay between transmission of characters. The default parameter is set to zero. Transmit Code ID Characters The code ID identifies a scanned bar code symbol’s code type. If enabled, the code ID is sent after the prefix and before the bar code data. The code ID codes are: • A = UPC-A, UPC-E, or EAN 13 • B = Code 39 • C = Codabar • D = Code 128 • E = Code 93 • F = Interleaved 2 of 5 • G = Discrete 2 of 5 The default parameter is disabled. Transmit AIM Code ID When enabled, the AIM code identifier is sent after the prefix and before the bar code data. The identifier is a three character prefix. Refer to AIM’s Guidelines on Symbology Identifiers for a description. The default parameter is disabled. Ignore Unknown Characters When enabled, all data is sent except for unknown characters and no error beeps are sounded. Unknown characters are those characters that the host device does not recognize. When disabled, all data containing one or more unknown characters is discarded and error beeps are sounded. The default parameter is enabled. Publication 2755-6.3
Page 58
Configuring Your Scanner
3–21
International Keyboard Emulation When enabled, this parameter allows you to send the code from the type of keyboard that you have. This parameter will allow you to select a national keyboard type. This parameter is supported by IBM AT/XT/PS2 computers only. The default parameter is disabled. International Keyboard Emulation Fast Transmit When enabled, this parameter allows you to send the code from the type of keyboard that you have quickly. This parameter will allow you to select a national keyboard type. This parameter is supported by some IBM AT/XT/PS2 computers only. The default parameter is disabled. National Keyboard Type Allows you to set the national character type for the keyboard you are using. Selections include U.S. English, French, German, French International, Spanish, Italian, Swedish, and U.K. English. The default parameter is set to U.S. English. Set Transmission Frequency Allows you to set the transmission channel of communication between the scanner gun and the base/charger unit. The default parameter is set to 50. Wait for Host Interface Response Time The scanning system automatically calculates the time it takes for base/charger unit to communicate with the host device and for the base/charger unit to send an acknowledgement back to the scanner. Under normal operating conditions, you should not enable this bar code option. If you need to enable this option, the timeout values can range from 1 to 99 seconds. If you receive error beeps while enabling this bar code, increase the timeout value until the error beeps stop. The default parameter is set to 00. Publication 2755-6.3
Page 59
3–22
Configuring Your Scanner
Configuration Sequence To configure the scanner: 1. Connect the base/charger unit to the host device. Refer to Chapter 2 for more information. 2. Make sure the scanner gun has a fully charged battery. Refer to Chapter 2 for more information. 3. Pair the scanner to the base/charger unit. Refer to Chapter 2 for more information. 4. Decide if the default values meet your requirements. Refer to page 3–3 for a listing of the default parameters. If the default values meet your requirements, scan the Set Defaults bar code located in the Hand-Held Cordless Bar Code Scanners Programming Guide (Publication No. 2755-6.6). If the default parameters do not meet your requirements, scan the appropriate bar codes for the options you need found in the Hand-Held Cordless Bar Code Scanners Programming Guide (Publication No. 2755-6.6). It is recommended that you scan the Set Defaults bar code before entering any additional bar codes. The scanner parameters may be configured in any sequence.
Publication 2755-6.3