The text of a manual · part 14 of 16
Hand-Held Cordless Bar Code Scanners (Cat. Nos. 2755-HCG-4 and 2755-HCG-7) User Manual: C - Advanced Data Formatting
Pages 92 to 97 of 107, from Hand-Held Cordless Bar Code Scanners (Cat. Nos. 2755-HCG-4 and 2755-HCG-7) User Manual
The original document is the PDF (451 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 2755-DS
Page 92
Appendix
C
Advanced Data Formatting This appendix describes how to use the Advanced Data Format (ADF) feature. Included are sections on: • ADF overview • rules hierarchy • default rule • listening for audible responses • using ADF in a sorting application
ADF Overview ADF allows you to customize input before it is transmitted to your host device. For example, instead of having a direct read of a bar code, you can now attach a message to it. ADF is implemented with a series of bar codes that have selectable parameters. [You do not have to type in the individual characters for your message but rather scan in the appropriate bar code located in the Hand-Held Cordless Bar Code Scanners Programming Guide (Publication No. 2755-6.6).] This series of bar codes is called a Rule and is used to evaluate input from the scanner. Rules are comprised of Criteria and Actions. Criteria are composed of an Input Source, Code Type, and Code Length. Actions are composed of Send Data, Send Keystroke, Setup Pause, and Send Preset Value. Criteria, Actions, and entire Rules may be erased by scanning the appropriate bar code.
Publication 2755-6.3
Page 93
C–2
Advanced Data Formatting
Input Source
Criteria
Code Type
Code Length
Rules
Send Data
Send Keystroke Actions Setup Pause
Send Preset Value
Criteria Criteria are used to select the bar codes that the Actions act upon. Criteria are composed of an Input Source, Code Type, and Code Length. Input Source is the source affected by using using ADF and is selected prior to creating any ADF rules. Code Type is the symbology selected. All code types must be scanned in succession prior to selecting other criteria. If you don’t select a code type, all code types are affected. Code Length allows you to define the number of characters the selected code type must contain. You can select multiple lengths for each rule. If you do not select a code length, selected code types of any length are affected. Publication 2755-6.3
Page 94
Advanced Data Formatting
C–3
Actions Actions allow you to select how to format data for transmission. Actions are composed of Send Data, Send Keystroke, Setup Pause, and Send Preset Value. Send Data allows you to send all the data that follows, send all the data up to a specific character selected from the alphanumeric keyboard bar code, or send the next number of characters (1 to 254) selected from the alphanumeric keyboard. Send Keystroke allows you to scan the bar code for the keystroke you wish to send. Setup Pause allows you to set the pause duration parameter prior to entering ADF. Send Preset Value allows you to send values 1 or 2 by scanning the appropriate bar code. • value 1 = scan suffix • value 2 = scan prefix
Rules Hierarchy The last rule entered is the first rule read by the scanner. The scanner reads the information and determines what needs to be accomplished. If the last rule read is valid, the scanner may not go on to the other rules so positioning of the rules is very important.
Default Rule The default rule is Send All Data. If all the rules you create do not meet the criteria, all the data is sent.
Publication 2755-6.3
Page 95
C–4
Advanced Data Formatting
Listening for an ADF Audible Response When scanning an ADF bar code symbol, you hear beeps from the scanner. Refer to the following tables to determine the meaning of the beeps.
Beep Indicating Normal Operation The duration of the following tones are short. This Response
Indicates
2 Beeps (high–low tone)
Entry of a number is expected. Enter another digit. Add leading zeros to the front if needed.
2 Beeps (low–low tone)
Entry of a alphabetic character is expected. Enter another alphabetic character or scan the End of Message bar code.
2 Beeps (high–high tone)
Entry of a Criteria or Action is expected. Enter another Criteria or Action or scan the Save Rule bar code.
4 Beeps (high–low–high–low tone)
The Rule is saved. Rule entry mode is exited.
3 Beeps (high–low–low tone)
All Criteria and Actions were cleared for the Rule currently being entered. Continue entry of Rule.
1 Beep (low tone)
Last saved Rule was successfully deleted. The Rule presently being entered is unchanged.
3 Beeps (low–low–high tone)
Publication 2755-6.3
All Rules are now deleted. The Rule presently being entered is left alone.
Page 96
Advanced Data Formatting
C–5
Beep Indicating Error The duration of the following tones are long. This Response
Indicates
4 Beeps (low–high–low–high tone)
Out of Rule memory. Erase some of the existing Rules, then try and save Rule again.
3 Beeps (low–high–low tone)
Cancel rule entry. Rule entry mode exited because of an error or you were asked to exit Rule entry.
2 Beeps (low–high tone)
The wrong bar code was scanned. Re–enter the Criteria or Action. All previously entered Criteria and Actions are retained. Criteria or Action list is too long for a Rule.
Publication 2755-6.3
Page 97
C–6
Advanced Data Formatting
ADF Sorting Application Example In this example, ADF is used to expand the message seen by assembly workers packing and sorting boxes on a conveyor line. Without ADF, the message reads: PURPLE 123
With ADF, the message reads: Place item in PURPLE box Place box on conveyor # 123
To expand the message by scanning the appropriate bar codes located in the Hand-Held Cordless Bar Code Scanners Programming Guide (Publication No. 2755-6.6), you need to: 1. Select the Input Source. 2. Select the Code Type. 3. Select the Code Length of PURPLE 123 including spaces. 4. Send Keystrokes of Place item in including spaces. 5. Send Data of PURPLE. 6. Send Keystrokes of box including space. 7. Send Preset including carriage return line feed. 8. Send keystrokes of Place box on conveyor # including spaces. 9. Send Data of 123. 10. Save Rule. Publication 2755-6.3