Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 7

StrataSet Programming Software Programming Guide (Cat. No. 2755-LHS-1), pages 44 to 49

Pages 44 to 49 of 49: Index; Back Cover

The original document is the PDF (345 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Allen-Bradley 2755-DS

Page 44 read from a scan by OCR; it may hold reading errors

2-1

A

AIM ID codes , 2 - 21 ALT characters, Control codes for, 2 - 23

B baud rate, 2 - 17 beeper, options, 2 - 29

C chapter objectives, P - 1 CLSI editing, 2 - 27 Codabar, 2 - 4 code types, 2 - 4 Codabar, 2 - 4 Code 128, 2 - 4 Code 39, 2 - 4 Code 39 Mod 43 check digit, 2 - 4 Code 93, 2 - 4 EAN, 2-4 EAN- - 13 disable, 2 - 4 EAN-8 disable, 2 - 4 full ASCII Code 39, 2 - 4 12 of 5, 2-4 12 of 5 Mod 10 check digit, 2 - 4 Paraf, 2 - 4 UPC, 2-4 UPC- - A disable, 2 - 4 UPC-E disable, 2 - 4 codes, reserve, 2 - 16

COM port, 1-5 commands, keyboard, 1 - 3 configuration options, 2 - 3 configuration screen, 1 - 4 configuring your reader, 2 - 2 contacting Allen - Bradley for assistance, P - 2 Contents of this Manual, P - 1

Control Codes, for ALT characters, 2 - 23

D data format, 2 - 17 even, 2-18 mark, 2 - 18 odd, 2 - 18 space, 2 - 18

Publication 2755-6.14

Page 45 read from a scan by OCR; it may hold reading errors

stop bits, 2 - 18 delay, transmission, 2 - 31 DOS, exit to, 1 - 6

E

ENTER key, 1-3 ESC key, 1-3 exit to DOS, 1-6

F

F1 key, 1-3

F10, key, 2 - 10

F3 key, 1-3

F5 key, 1-3

F7 key, 1-3

F9 key, 1 - 3 file list, 1 - 5 firmware version, 1 - 6 format data, 2 - 17 interface, 2 - 3 RS232, 2 - 16 Schlumberger/Shell, 2 - 20 wand emulation, 2 - 23 formatting non - UPC, 2-27 UPC, 2-25 further RS232 options ACK/NAK, 2 - 18 RTS/CTS handshaking, 2 - 20

H hand-held port, 2 - 32 Hi/Output, 2 - 24 identifiers Nixdorf ID, 2 - 20 programmable prefix, 2 - 22 programmable suffix, 2 - 22

Intended Audience, P - 2 interface format, 2 - 3

Publication 2755-6.14

Page 46 read from a scan by OCR; it may hold reading errors

2-3

K key

ENTER, 1 - 3 ESC, 1-3

Fl, 1 - 3

F10, 2 - 10

F3, 1-3

F5, 1-3

F7, 1-3 F9,1 - 3 space bar, 1 - 3 keyboard commands, 1 - 3

L

LED, options, 2 - 29 length specifiers, 2 - 28 I2 of 5 locks, 2 - 28 others, 2 - 28

M main menu, 1 - 4 manual contents, P - 1 manual conventions, P - 2 menus for StrataSet, 1 - 2 miscellaneous beep, 2 - 8 disables, 2 - 8 enables, 2 - 8 reverse LED convention, 2 - 9 timeout, 2 - 8 miscellaneous options, 2 - 7 mode normal, 2 - 32 one-shot, 2 - 32 pulsing, 2 - 32

N non - UPC, formatting, 2 - 27

O options beeper, 2 - 29 further RS232, 2-18 LED, 2-29

Publication 2755-6.14

Page 47 read from a scan by OCR; it may hold reading errors

2-4 output activate AC, 2-13 support AC, 2 - 12 p package detect, 2 - 11 enable read and match, 2 - 13

Poll source, 2 - 23 port, hand - held, 2 - 32

Program mode Enter, 1 - 5 Exit, 1-6

R rate, baud, 2 - 17

Related Publications, P - 2 reserve codes, 2 - 16 RS232, 2 - 3, 2 - 16

RS422, 2-3

S same symbol, timeout, 2 - 30 scan range, 2 - 15 scanner settings, 1 - 5 select COM port, 1-5 software version, 2 - 2 space bar, 1 - 3 specifiers, length, 2 - 28 starting StrataSet, 1 - 1 supplementals, 2 - 5 2 - digit, 2-6 5 - digit, 2 - 6 Bookland, 2 - 6 Code 128 conversion, 2 - 6 milliseconds to find, 2 - 6 redundancy, 2 - 6

T

Technical Support, P - 2 testing option, 2 - 3 timeout, same symbol, 2 - 30 transmission delay, 2 - 31

Publication 2755-6.14

Page 48 read from a scan by OCR; it may hold reading errors

transmit AIM ID character, 2 - 21 Sanyo ID character, 2 - 22

U

UPC formatting, 2 - 25

W wand emulation, 2 - 3, 2 - 23 wand type 10 or 50 times narrow element, 2 - 24 extra transition before bar code, 2 - 24 hi/output, 2 - 24 narrow element size, 2 - 24 poll source, 2 - 23

Publication 2755-6.14

Page 49

Rockwell Automation helps its customers receive a superior return on their investment by bringing together leading brands in industrial automation, creating a broad spectrum of easy-to-integrate products. These are supported by local technical resources available worldwide, a global network of system solutions providers, and the advanced technology resources of Rockwell.

Worldwide representation. Argentina • Australia • Austria • Bahrain • Belgium • Bolivia • Brazil • Bulgaria • Canada • Chile • China, People’s Republic of • Colombia • Costa Rica • Croatia • Cyprus Czech Republic • Denmark • Dominican Republic • Ecuador • Egypt • El Salvador • Finland • France • Germany • Ghana • Greece • Guatemala • Honduras • Hong Kong Hungary • Iceland • India • Indonesia • Iran • Ireland • Israel • Italy • Jamaica • Japan • Jordan • Korea • Kuwait • Lebanon • Macau • Malaysia • Malta • Mexico • Morocco The Netherlands • New Zealand • Nigeria • Norway • Oman • Pakistan • Panama • Peru • Philippines • Poland • Portugal • Puerto Rico • Qatar • Romania • Russia • Saudi Arabia • Singapore • Slovakia • Slovenia • South Africa, Republic of • Spain • Sweden • Switzerland • Taiwan • Thailand • Trinidad • Tunisia • Turkey • United Arab Emirates United Kingdom • United States • Uruguay • Venezuela Rockwell Automation Headquarters, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444 Rockwell Automation European Headquarters, Avenue Hermann Debroux, 46, 1160 Brussels, Belgium, Tel: (32) 2 663 06 00, Fax: (32) 2 663 06 40 Rockwell Automation Asia Pacific Headquarters, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846 World Wide Web: http://www.ab.com

Publication 2755-6.14

PN 40062-390-01 (A) Copyright 1997 Rockwell International Corporation. All rights reserved. Printed in USA

Publication 2755-6.14