The text of a manual · part 8 of 9
StrataScan Bar Code Readers (Cat. Nos. 2755-LHR-5B, 2755-LHR-3C, 2755-LHR-5C, and 2755-LHR-5BX1) User Manual: B - Cable Pinouts
Pages 53 to 62 of 68, from StrataScan Bar Code Readers (Cat. Nos. 2755-LHR-5B, 2755-LHR-3C, 2755-LHR-5C, and 2755-LHR-5BX1) User Manual
The original document is the PDF (649 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 2755-DS
Page 53
Cable Pinouts This appendix provides the cable pinouts for the readers, interface box, power supply, and assorted cables.
Publication 2755-6.13
Page 54
B–2
Cable Pinouts
Reader Pinouts
The following sections provide the pinouts for the StrataScan Bar Code Readers (Catalog Nos. 2755-LHR-5B,-3C, -5C and 5BX1).
RS-232 Port 1
13
14
Pin
Publication 2755-6.13
25
Signal
Function
1
GND
Chassis ground
2
RXD
Reader receives data from the host device.
3
TXD
Reader transmits data to the host device.
4
CTS Input
Reader is requesting data from the host device.
5
RTS Output
Host device is requesting data from the reader.
6
Not Used
Pin not used.
7
GND
Signal ground
8
Not used
Pin not used.
9
RXB–
Reader receives data from the host device (RS-422).
10
RXA+
Reader receives data from the host device (RS-422).
11
TXY+
Host transmit data to the reader (RS-422).
12
TXZ–
Host transmit data to the reader (RS-422).
13
GND
Ground
14
GND
Ground
15
Not Used
Pin not used.
16
Not Used
Pin not used.
17
Not Used
Pin not used.
18
Not Used
Pin not used.
19
Not Used
Pin not used.
20
DTR Input
The data terminal is ready.
21
Not Used
Pin not used.
22
Not Used
Ground
23
Not Used
Pin not used.
24
Not Used
Pin not used.
25
GND
Ground
Page 55
Cable Pinouts
B–3
Interface Box Port 1
8
9
Pin
15
Signal
Function
1
RXD
Reader receives data from the interface box.
2
CTS
Reader is requesting data from the interface box.
3
Not Used
Pin not used.
4
Not Used
Pin not used.
5
Triac+
Controls the triac input.
6
Sensor+
Pin that provides the sensor’s object detected input signal.
7
Sensor Alarm+
Pin that provides the sensor’s optional marginal sensing alarm input signal.
8
Not Used
Pin not used.
9
TXD
Reader transmit data to the interface box.
10
RTS
Interface box is requesting data from the reader.
11
GND
Signal ground
12
Not used
Pin not used.
13
Triac–
Controls the triac input.
14
Sensor–
Pin that provides the sensor’s object detected input signal.
15
Sensor Alarm–
Pin that provides the sensor’s optional marginal sensing alarm input signal.
Publication 2755-6.13
Page 56
B–4
Cable Pinouts
Power Supply Port 1
5
6
9
Pin
Function
1
12V dc input power to the reader.
2
12V dc input power to the reader.
3
Earth ground
4
Power ground
5
Power ground
6
12V dc input power to the reader.
7
12V dc input power to the reader.
8
Power ground
9
Power ground
Hand–Held Port Pinouts 1
5
6
9
Pin
Signal
Function
1
Start of Scan
Synchronizes decode logic with the scanner.
2
Digitized Bar Pattern
Input receives a series of pulses proportional to the widths of bar code being scanned from the hand-held scanner.
3
Decode LED
Controls green decode LED on hand-held scanner.
5
Trigger Switch
Connected to trigger switch of the hand-held scanner
6
Enable
Signal output to power up the hand-held scanner, turn on the laser, and turn on the scanning motor.
7
Ground
8
Shield ground
9
Power
+5V dc to power hand-held scanner
Note: Place a female contact in pin 4 of the 9–pin hand–held connector.
Publication 2755-6.13
Page 57
Cable Pinouts
B–5
Interface Box Pinouts G
H
A B
F E
C D
Pin
Signal
Function
A
Triac+
Controls the triac input.
B
Triac–
Controls the triac input.
C
Sensor+
Provides the sensor’s object detected input signal.
D
Sensor–
Provides the sensor’s object detected input signal.
E
Sensor Alarm
Provides the sensor’s optional marginal sensing alarm input signal.
F
Sensor Alarm
Provides the sensor’s optional marginal sensing alarm input signal.
G
Not Used
Pin not used.
H
Not Used
Pin not used.
Publication 2755-6.13
Page 58
B–6
Cable Pinouts
Power Supply Pinouts 1
5
6
9
Pin
Publication 2755-6.13
Function
1
12V dc input power to the reader.
2
12V dc input power to the reader.
3
Earth ground
4
Power ground
5
Power ground
6
12V dc input power to the reader.
7
12V dc input power to the reader.
8
Power ground
9
Power ground
Page 59
Cable Pinouts
Reader Master/slave Cable Pinouts
B–7
Slave Reader Connector Master Reader Connector
13
25
1
9
15
8 1
14
Master Reader Connector (15-Pin) Pin Number
Signal from Master Reader
Slave Reader Connector (25-Pin) Pin Number
1
RXD (input)
3
2
CTS (output)
4
9
TXD (output)
2
10
RTS (input)
5
11
GND
7
Publication 2755-6.13
Page 60
B–8
Cable Pinouts
Reader Null Modem Cable Pinouts
Reader Connector 13 PC or PLC Connector
25
1
6
9 5
1
Publication 2755-6.13
14
PC or PLC Connector (9-Pin) Pin Number
Signal from Reader
Reader Connector (25-Pin) Pin Number
3
RS-232 Receive
2
2
RS-232 Transmit
3
7
CTS (input)
4
8
RTS (output)
5
5
GND
7
4
DTR (input)
20
Page 61
Cable Pinouts
Interface Box Cable Pinouts
B–9
Reader Connector 9
1 Interface Box Connector A
H
G F
B C
E D
15
8
Reader Connector (15-Pin) Pin Number
Signal from Reader
Interface Box Connector (8-Pin) Pin Number
5
Triac+
A
13
Triac–
B
6
Sensor+
C
14
Sensor–
D
7
Sensor alarm+
E
15
Sensor alarm–
F
Publication 2755-6.13
Page 62
B–10
Cable Pinouts
Interface Box Master/slave Cable Pinouts
Slave Reader Connector Master Reader Connector 9
Interface Box Connector H
A
13
25
1
G F
B C
E D
15
8 14
1
Publication 2755-6.13
Interface Box Connector (8-Pin) Pin Number
Master Reader Connector (15-Pin) Pin Number
Signal from Master Reader
Slave Reader Connector (25-Pin) Pin Number
No connection
1
RXD (input)
3
No connection
2
CTS (output)
4
A
5
Triac+
No connection
C
6
Sensor+
No connection
E
7
Sensor alarm+
No connection
No connection
9
TXD (output)
2
No connection
10
RTS (input)
5
No connection
11
GND
7
B
13
Triac–
No connection
D
14
Sensor–
No connection
F
15
Sensor alarm–
No connection